Products catalog

  • Single-phase voltage relay with current limiting | 1F | 50 A (max. 60 A) | U> 210–270 V | U< 120–200 V | red display | DIN | DigiTOP | VA-50A

    Code: VA-50A

    The DigiTOP VA-50A is a single-phase digital voltage relay with current measurement and limiting.

  • Single-phase voltage relay with current limiting | 1F | 50 A (max. 60 A) | U> 210–270 V | U< 120–200 V | red display | DIN | DigiTOP | VA-50A

    The DigiTOP VA-50A is a single-phase digital voltage relay with current measurement and limiting. The full load passes through its contact (50 A (briefly up to 60 A)); the display shows both voltage and load current. The relay disconnects the load when the voltage leaves the set limits or when the load exceeds the permitted current.

    Key point:
    One 2–3 module device combines protection against over- and undervoltage, the consequences of a broken neutral, and load limiting. This is useful when the connection capacity is limited or when an overloaded circuit should be switched off before the main circuit breaker trips.
    Load current
    50 A (max. 60 A)
    Voltage limits
    U> 210–270 V, U< 120–200 V
    Switch-on delay
    5–600 s
    Current limiting
    up to 60 A, disconnects when exceeded

    How it works

    The relay is installed in the board after the main circuit breaker: phase and neutral to the input, the protected load to the output. A microcontroller continuously measures the mains voltage and shows it on the display.

    If the voltage rises above the upper limit (210–270 V) or drops below the lower limit (120–200 V), the relay disconnects the load: above the upper limit within hundredths of a second, at 120–170 V within up to 1 s, below 120 V instantly.

    An internal current transformer measures the load current. If the permitted current is exceeded, the load is disconnected: above the maximum current within hundredths of a second, with prolonged overload above rated current after a protective delay. This also limits the power drawn.

    When the voltage returns to normal, the load is reconnected after the set delay (5–600 s). For fridges, heat pumps and air conditioners the manufacturer recommends a delay of at least 300 s.

    Why choose the VA-50A?
    It protects all appliances connected after it from a broken neutral, overvoltage and undervoltage, and the display always shows the actual mains voltage. It also limits the load – an overloaded circuit is disconnected before the main circuit breaker trips.

    Technical specifications

    Product type Single-phase voltage relay with current measurement and limiting
    Manufacturer / model DigiTOP / VA-50A
    Network 1F, 230 V AC
    Rated load current 50 A
    Maximum load current 60 A
    Rated power (resistive load) 11 kW
    Measured voltage 50–400 V
    Upper limit U> 210–270 V (factory 250 V)
    Lower limit U< 120–200 V (factory 170 V)
    Trip time below the limit up to 1 s (120–170 V), instantly below 120 V
    Switch-on delay 5–600 s, 5 s step (factory 15 s)
    Current measurement internal current transformer, error up to 1 %
    Current limiting can be switched on / off
    Voltage measurement error up to 1 %
    Display LED, red
    Maximum wire cross-section 16 mm²
    Width 3 DIN modules of 17.5 mm
    Mounting 35 mm DIN rail
    Operating temperature −25…+50 °C
    Degree of protection IP20 (in damp locations only in a sealed enclosure)
    Service life 10 years
    Manufacturer warranty 2 years

    Main functions

    • Overvoltage protection – with a broken neutral or a network fault, appliances are disconnected before their power supplies burn out.
    • Undervoltage protection – compressors and pumps do not run at a voltage at which motors overheat.
    • Adjustable switch-on delay 5–600 s – the compressor starts only after pressure has equalised, equipment does not cycle during an unstable supply.
    • Digital voltage display – you see immediately whether the problem is in the grid or in the house.
    • Current measurement and limiting – an overloaded circuit is disconnected, the load current is shown on the display.
    • Last trip memory – you can check at what voltage it disconnected; settings are kept during a power cut.

    Where is it used?

    • Apartment and house supplies (after the main circuit breaker)
    • Electronics of gas and solid-fuel boilers and heat pumps
    • Supplies with limited permitted power
    • Fridges, freezers, air conditioners
    • Country houses and homes with a weak or long overhead line
    • Rental properties and unattended sites
    • Offices, server and security system supplies
    • Generator-supplied circuits

    Use by need

    For the home or apartment owner.
    One device protects all appliances against a broken neutral and voltage surges.
    For the electrician.
    Simple installation after the main circuit breaker; limits and delay are set with buttons in a few minutes.
    When the supply capacity is limited.
    The relay disconnects an overloaded circuit, so the main circuit breaker and fuses trip less often.

    Practical use

    A house has a three-phase supply with single-phase equipment distributed among the phases. If the neutral contact in the board burns out, the voltage on one phase rises to 300–380 V. The VA-50A disconnects the load before the boiler controller and power supplies burn out, and after the neutral is restored the equipment is switched on after the set delay. In a three-phase house such a relay is installed for each phase supplying single-phase equipment, or a three-phase voltage relay is used instead.

    Pros

    • Full load through the relay – no additional contactor needed
    • Current measurement and limiting in the same device
    • Fast disconnection above the upper limit
    • Adjustable limits and switch-on delay
    • Digital voltage display
    • Compact DIN housing
    • Manufacturer warranty 2 years

    Cons / limitations

    • Does not protect against lightning and short surges – an SPD is needed
    • Does not replace a circuit breaker or residual current device (RCD)
    • Single-phase – a three-phase house needs a relay per phase or a three-phase relay
    • IP20 – dry board only

    Safety and installation notes

    • Install only after disconnecting the supply and checking that no voltage is present; work must be done by a qualified electrician.
    • A circuit breaker with a rated current not higher than the relay's rated current must be installed upstream.
    • Use ferrules for stranded wires and tighten terminals to the torque specified by the manufacturer.
    • Do not swap phase and neutral – otherwise the phase remains connected to the equipment when the relay trips.
    • Install the surge protective device (SPD) before the relay, closer to the supply point.
    • Do not install in damp, vibrating or explosive environments.

    Quick selection guide

    1F | 230 V
    50 A | max. 60 A
    U> 210–270 V
    U< 120–200 V
    delay 5–600 s
    Suitable when you need:
    • to protect an apartment, house or circuit against a broken neutral
    • to protect a boiler, fridge or heat pump
    • to see the mains voltage in the board
    Check before use:
    • main circuit breaker current ≤ 50 A
    • whether a surge protective device (SPD) is installed
    • set a delay of ≥ 300 s for compressors
    Important reminder: a voltage relay does not replace a surge protective device, a circuit breaker or an RCD – each protects against a different hazard.

    FAQ

    Does the relay protect against lightning?
    No – a lightning impulse lasts microseconds; a surge protective device (SPD) protects against it.
    Which relay should I choose for my circuit breaker?
    The relay's rated current must be at least the current of the upstream circuit breaker – the VA-50A suits a breaker up to 50 A.
    What switch-on delay should I set?
    For fridges and compressors at least 300 s; 15–30 s is enough for lighting and electronics.
    Why does the relay trip often?
    Most likely the limits are too narrow for a weak network – measure the mains voltage first and only then adjust the limits.
    Can it be installed in a three-phase house?
    Yes – a single-phase relay is installed on each phase supplying the protected equipment.
    Does the relay replace an RCD?
    No – only a residual current device (RCD) protects people from electric shock.

    Single-phase voltage relay with current limiting | 1F | 50 A (max. 60 A) | U> 210–270 V | U< 120–200 V | red display | DIN | DigiTOP | VA-50A

    Single-phase voltage relay with current limiting DigiTOP VA-50A – voltage monitoring and load limiting in one device for a single-phase supply or circuit.

    Published: 2026-11-13 · Data verified against the manufacturer's manual: 2026-11-13