Single-phase voltage relay with current limiting | 1F | 63 A (max. 80 A) | U> 210–270 V | U< 120–200 V | red display | DIN | DigiTOP | VA-63A
Code: VA-63APrice 65.12 € VAT incl.( 53.82 € VAT excl. )The DigiTOP VA-63A is a single-phase digital voltage relay with current measurement and limiting.
-
Single-phase voltage relay with current limiting | 1F | 63 A (max. 80 A) | U> 210–270 V | U< 120–200 V | red display | DIN | DigiTOP | VA-63A
The DigiTOP VA-63A is a single-phase digital voltage relay with current measurement and limiting. The full load passes through its contact (63 A (briefly up to 80 A)); the display shows both voltage and load current. The relay disconnects the load when the voltage leaves the set limits or when the load exceeds the permitted current.
Key point:
One 2–3 module device combines protection against over- and undervoltage, the consequences of a broken neutral, and load limiting. This is useful when the connection capacity is limited or when an overloaded circuit should be switched off before the main circuit breaker trips.Load current
63 A (max. 80 A)Voltage limits
U> 210–270 V, U< 120–200 VSwitch-on delay
5–600 sCurrent limiting
up to 80 A, disconnects when exceededHow it works
The relay is installed in the board after the main circuit breaker: phase and neutral to the input, the protected load to the output. A microcontroller continuously measures the mains voltage and shows it on the display.
If the voltage rises above the upper limit (210–270 V) or drops below the lower limit (120–200 V), the relay disconnects the load: above the upper limit within hundredths of a second, at 120–170 V within up to 1 s, below 120 V instantly.
An internal current transformer measures the load current. If the permitted current is exceeded, the load is disconnected: above the maximum current within hundredths of a second, with prolonged overload above rated current after a protective delay. This also limits the power drawn.
When the voltage returns to normal, the load is reconnected after the set delay (5–600 s). For fridges, heat pumps and air conditioners the manufacturer recommends a delay of at least 300 s.
Why choose the VA-63A?
It protects all appliances connected after it from a broken neutral, overvoltage and undervoltage, and the display always shows the actual mains voltage. It also limits the load – an overloaded circuit is disconnected before the main circuit breaker trips.Technical specifications
Product type Single-phase voltage relay with current measurement and limiting Manufacturer / model DigiTOP / VA-63A Network 1F, 230 V AC Rated load current 63 A Maximum load current 80 A Rated power (resistive load) 13.9 kW Measured voltage 50–400 V Upper limit U> 210–270 V (factory 250 V) Lower limit U< 120–200 V (factory 170 V) Trip time below the limit up to 1 s (120–170 V), instantly below 120 V Switch-on delay 5–600 s, 5 s step (factory 15 s) Current measurement internal current transformer, error up to 1 % Current limiting can be switched on / off Voltage measurement error up to 1 % Display LED, red Maximum wire cross-section 16 mm² Width 3 DIN modules of 17.5 mm Mounting 35 mm DIN rail Operating temperature −25…+50 °C Degree of protection IP20 (in damp locations only in a sealed enclosure) Service life 10 years Manufacturer warranty 2 years Main functions
- Overvoltage protection – with a broken neutral or a network fault, appliances are disconnected before their power supplies burn out.
- Undervoltage protection – compressors and pumps do not run at a voltage at which motors overheat.
- Adjustable switch-on delay 5–600 s – the compressor starts only after pressure has equalised, equipment does not cycle during an unstable supply.
- Digital voltage display – you see immediately whether the problem is in the grid or in the house.
- Current measurement and limiting – an overloaded circuit is disconnected, the load current is shown on the display.
- Last trip memory – you can check at what voltage it disconnected; settings are kept during a power cut.
Where is it used?
- Apartment and house supplies (after the main circuit breaker)
- Electronics of gas and solid-fuel boilers and heat pumps
- Supplies with limited permitted power
- Fridges, freezers, air conditioners
- Country houses and homes with a weak or long overhead line
- Rental properties and unattended sites
- Offices, server and security system supplies
- Generator-supplied circuits
Use by need
For the home or apartment owner.
One device protects all appliances against a broken neutral and voltage surges.For the electrician.
Simple installation after the main circuit breaker; limits and delay are set with buttons in a few minutes.When the supply capacity is limited.
The relay disconnects an overloaded circuit, so the main circuit breaker and fuses trip less often.Practical use
A house has a three-phase supply with single-phase equipment distributed among the phases. If the neutral contact in the board burns out, the voltage on one phase rises to 300–380 V. The VA-63A disconnects the load before the boiler controller and power supplies burn out, and after the neutral is restored the equipment is switched on after the set delay. In a three-phase house such a relay is installed for each phase supplying single-phase equipment, or a three-phase voltage relay is used instead.Pros
- Full load through the relay – no additional contactor needed
- Current measurement and limiting in the same device
- Fast disconnection above the upper limit
- Adjustable limits and switch-on delay
- Digital voltage display
- Compact DIN housing
- Manufacturer warranty 2 years
Cons / limitations
- Does not protect against lightning and short surges – an SPD is needed
- Does not replace a circuit breaker or residual current device (RCD)
- Single-phase – a three-phase house needs a relay per phase or a three-phase relay
- IP20 – dry board only
Safety and installation notes
- Install only after disconnecting the supply and checking that no voltage is present; work must be done by a qualified electrician.
- A circuit breaker with a rated current not higher than the relay's rated current must be installed upstream.
- Use ferrules for stranded wires and tighten terminals to the torque specified by the manufacturer.
- Do not swap phase and neutral – otherwise the phase remains connected to the equipment when the relay trips.
- Install the surge protective device (SPD) before the relay, closer to the supply point.
- Do not install in damp, vibrating or explosive environments.
Quick selection guide
1F | 230 V63 A | max. 80 AU> 210–270 VU< 120–200 Vdelay 5–600 sSuitable when you need:- to protect an apartment, house or circuit against a broken neutral
- to protect a boiler, fridge or heat pump
- to see the mains voltage in the board
Check before use:- main circuit breaker current ≤ 63 A
- whether a surge protective device (SPD) is installed
- set a delay of ≥ 300 s for compressors
Important reminder: a voltage relay does not replace a surge protective device, a circuit breaker or an RCD – each protects against a different hazard.FAQ
Does the relay protect against lightning?
No – a lightning impulse lasts microseconds; a surge protective device (SPD) protects against it.Which relay should I choose for my circuit breaker?
The relay's rated current must be at least the current of the upstream circuit breaker – the VA-63A suits a breaker up to 63 A.What switch-on delay should I set?
For fridges and compressors at least 300 s; 15–30 s is enough for lighting and electronics.Why does the relay trip often?
Most likely the limits are too narrow for a weak network – measure the mains voltage first and only then adjust the limits.Can it be installed in a three-phase house?
Yes – a single-phase relay is installed on each phase supplying the protected equipment.Does the relay replace an RCD?
No – only a residual current device (RCD) protects people from electric shock.Single-phase voltage relay with current limiting | 1F | 63 A (max. 80 A) | U> 210–270 V | U< 120–200 V | red display | DIN | DigiTOP | VA-63A
Single-phase voltage relay with current limiting DigiTOP VA-63A – voltage monitoring and load limiting in one device for a single-phase supply or circuit.
Published: 2026-11-13 · Data verified against the manufacturer's manual: 2026-11-13
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Surface-Mounted Modular Hermetic Panel for Above-Plaster Installation IP65 PLEXO LegrandCode: Plexo IP65Key Features:
Fire Resistance:
The panels are fire-resistant up to 650°C, tested using the glowing wire test to ensure safety in demanding environments.
Compliance:The panels comply with IEC 61 439-3 standards, ensuring they meet the highest international requirements for low-voltage switchgear and control gear assemblies.
Weatherproof Design:Modular panels are rated IP65, providing full protection against dust and low-pressure water jets, making them suitable for outdoor and harsh weather conditions.
With an IK09 impact resistance rating, the panels can withstand high levels of mechanical shock.
Classified under Class II, meaning they provide double insulation for added electrical safety.
Fully Reversible Design:Both the doors and cabinet can be completely reversed, allowing for flexible installation depending on the available space or specific project requirements.
Removable DIN Rails and Front Panels:From the 24-module version (2 rows) onwards, the DIN rails and front panels are easily removable, facilitating quick and straightforward installation or modification of electrical components.
150 mm Distance Between Rails:The distance between the rails is 150 mm, offering enough space for comfortable cable routing and installation of electrical devices.
Optional Perforated and Solid Front Plates:The panels can be equipped with perforated plates or solid front panels, allowing for the installation of non-modular devices, making them versatile for different types of electrical systems.
Lockable Handle:The door features a lockable handle, enhancing security and preventing unauthorized access to the electrical components.
Sealed Cover and Front Panel:Both the cover and front panel are tightly sealed, ensuring the panel maintains its IP65 rating and protection from dust and moisture.
Impact-Resistant Material:The enclosures are made from impact-resistant polystyrene, ensuring durability and protection against mechanical damage.
Color:The box color is light grey L750A, and the cover color is dark grey R746A, providing a clean and professional appearance suitable for both industrial and commercial settings.
Supplied with PE and N Terminal Blocks:The panels are equipped with PE (protective earth) and N (neutral) terminal blocks for convenient and safe electrical connections.
Price 15.28 € - 177.01 € VAT incl.( 12.63 - 146.29 € VAT excl. )Copper installation cable NYM-J | 3×2.5 mm² | 300/500 V | white | 1 m | Lietkabelis KH05VV-U 3G2.5Code: 92032501 (1m)NYM-J 3×2.5 mm² (KH05VV-U 3G2.5) – AB Lietkabelis copper installation cable with solid class 1 conductors, PVC insulation and a white PVC sheath, 300/500 V. For fixed installation inside buildings: in walls, under plaster, in conduits and trunking. Sold by the metre.
3 cores (L, N, PE) for single-phase 230 V installation: lighting, socket and dedicated appliance circuits.
Price 1.42 € VAT incl.( 1.17 € VAT excl. )