Products catalog

  • Smart circuit breaker | 4P | 63 A | C | 6 kA | 400 V AC | WiFi Tuya + RS485 | energy metering | residual current protection | GEYA GYRC-ZN01

    Code: ESGYRC-ZN011

    Smart automatic circuit breaker (MCB) with Wi-Fi control, designed for remote switching on/off of electrical circuits and overload protection. Integration with the TUYA Smart Home platform allows convenient power management via a mobile app, enabling timers, scenarios, and real-time status monitoring. This circuit breaker is intended for three-phase (3F + N) electrical systems, making it suitable for residential buildings, commercial premises, workshops, automation solutions, and smart electrical panels. 

  • Smart circuit breaker | 4P | 63 A | C | 6 kA | 400 V AC | WiFi Tuya + RS485 | energy metering | residual current protection | GEYA GYRC-ZN01

    GEYA GYRC-ZN01 – a three-phase 4-pole smart circuit breaker with a 63 A rated current, C curve and 6 kA breaking capacity. In a single housing it combines overload and short-circuit protection, residual current, voltage and phase monitoring, energy metering and remote control via the Tuya Smart app (WiFi) and RS485.

    Key idea:
    This is not just a breaker but a “guardian” of a three-phase supply or a high-power circuit: you see voltage, current and consumption on your phone, can disconnect the site remotely, and in the event of a voltage surge, phase loss or overload the breaker trips by itself and, if you allow it, switches back on automatically. Especially relevant for sites that are not permanently occupied.
    Rated current
    63 A, 4P, 400 V AC
    Protection
    C curve, Icu = Ics = 6 kA
    Residual current protection
    adjustable 30–500 mA
    Communication
    WiFi (Tuya Smart) + RS485

    How it works

    The breaker is mounted in a distribution board on a DIN rail or screwed to a mounting plate; three phases and neutral are connected to it. Once connected to a WiFi network, it is paired with the Tuya Smart / Smart Life app, while the RS485 interface allows integration into a building management or monitoring system.

    During operation the breaker continuously measures voltage, current and power on each phase, residual current and internal temperature. When a set limit is exceeded – voltage, current, leakage, imbalance or temperature – the circuit is disconnected in less than 0.1 s. The threshold and delay (0–10 s) of each parameter are set in the app.

    The result is a three-phase supply that can be monitored, controlled and protected from anywhere, and after a short-term grid disturbance power is restored automatically, without a trip to the site.

    Why choose GYRC-ZN01?
    Instead of a separate circuit breaker, RCD, voltage relay, energy meter and remote control module, you get one device with a single app. Fewer components in the board and fewer connections to maintain.

    Technical specifications

    Product type Smart circuit breaker with residual current protection and energy metering
    Manufacturer / model GEYA GYRC-ZN01
    Number of poles 4P (3 phases + N)
    Rated current 63 A
    Rated voltage / frequency 400 V AC (three-phase network), 50 Hz
    Tripping characteristic C
    Breaking capacity Icu = Ics = 6 kA
    Residual current threshold 30–500 mA (default 100 mA); sudden leakage change threshold 30–100 mA
    Overvoltage / undervoltage 250–350 V (default 280 V) / 110–200 V (default 165 V), delay 0–10 s
    Overload adjustable 0.6–1.0 × In, delay 0–10 s
    Other protections phase loss, voltage and current imbalance (5–30 %), overtemperature (60–100 °C), underpower / overpower
    Metering voltage, current, power, energy consumed; accuracy class 1.0
    Communication WiFi 2.4 GHz (Tuya Smart / Smart Life) + RS485 (default baud rate 9600 bps)
    Control app, timers, manual operation, automatic reclosing
    Closing / opening time < 1.5 s / < 0.1 s
    Service life mechanical > 12 000 cycles, electrical > 6 000 cycles
    Mounting DIN rail or screw mounting, screw terminals
    Degree of protection IP20 (for installation in a distribution board)
    Standards declared by the manufacturer GB/T 16917, CQC1149

    Key functions

    • Remote switching on and off – disconnect the site from your phone, no need to travel to the board.
    • Per-phase energy metering – see load and consumption, making it easier to find what is “eating” electricity.
    • Voltage and phase-loss protection – protects motors, pumps and electronics against overvoltage, undervoltage and running on a missing phase.
    • Adjustable residual current protection – set the threshold to suit the site, from 30 mA.
    • Automatic reclosing – after a short grid disturbance power is restored by itself; the function can be disabled.
    • Timers and scenes – switch the circuit on a schedule, e.g. during cheaper tariff hours.
    • RS485 interface – the breaker can be connected to a building management or monitoring system.

    Where is it used?

    • Three-phase supply of a house, country house or summer cottage
    • Rental apartments and commercial premises – remote disconnection and consumption control
    • Heat pumps, electric boilers and water heaters
    • Water pumping stations, boreholes and irrigation systems
    • Workshops, small production halls and machine tools
    • Agricultural buildings, warehouses, garages
    • EV charging circuits (with the separately required protection)
    • Mobile and temporary sites: construction sites, event power supply

    Use by need

    For country house or cottage owners.
    On arrival there is no need to search for why there is no power – the app shows what happened, and power can be switched on in advance.
    For rental property managers.
    You see consumption for each property separately and disconnect power remotely between tenants.
    For farm or workshop owners.
    Pumps and motors are protected against phase loss and voltage surges, and you learn about a fault immediately.

    Practical use

    If one phase is lost at a country house with a borehole pump and a heat pump, GYRC-ZN01 disconnects the entire supply within a few seconds, so the motors do not run on a missing phase and do not burn out. When normal voltage returns, the breaker switches back on automatically, and a record of when and why it tripped remains on your phone.

    Pros

    • Many protections in one device: MCB, residual current, voltage, phases, temperature
    • All thresholds and delays are adjustable
    • Energy metering, accuracy class 1.0
    • WiFi and RS485 at the same time
    • Automatic reclosing without travelling to the site
    • 6 kA breaking capacity, C curve

    Cons / limitations

    • The manufacturer declares Chinese standards (GB/T 16917, CQC); where an EN 61009 RCBO or a type A RCD is mandatory, use a separate certified RCD
    • Default residual current threshold is 100 mA – for personal protection it must be set to 30 mA
    • Remote control requires a stable 2.4 GHz WiFi
    • Energy metering is not MID certified – for billing tenants, choose a MID meter
    • Wider than a standard 4P MCB – leave space in the board

    Safety and installation notes

    • Installation and configuration by a qualified electrician only, with the power disconnected.
    • The rated current of 63 A must match the current-carrying capacity of the protected cable (In ≤ Iz).
    • Check that the short-circuit current at the installation point does not exceed 6 kA.
    • After connection, set the residual current, voltage and overload thresholds in the app to suit the site – the factory settings are not suitable everywhere.
    • Disable automatic reclosing in circuits where sudden switching on could be dangerous (machine tools, hoists).
    • Connect the N conductor – without it, voltage metering and the protections will not work correctly.

    Quick selection guide

    4P | 63 A
    C | 6 kA
    Leakage 30–500 mA
    WiFi Tuya | RS485
    Suitable when you need:
    • to control and monitor a three-phase supply or high-power circuit remotely;
    • to protect equipment against voltage surges and phase loss;
    • to restore power automatically at an unoccupied site.
    Check before use:
    • that 63 A matches the cable cross-section and load;
    • that there is enough space in the board and WiFi coverage there;
    • that the site does not require a certified type A RCD.
    Important reminder: the breaker does not replace a surge protective device (SPD) against lightning surges or a MID-certified meter for billing.

    FAQ

    Does the breaker work without the internet?
    Yes – the protections work independently; without WiFi, only remote control and app data are unavailable.
    Which app should I use?
    Tuya Smart or Smart Life; through them the breaker can also be linked with Google Home or Alexa.
    Will it replace an RCD?
    Functionally it has residual current protection from 30 mA, but where the project requires an EN 61009 / EN 61008 certified device, install a separate RCD.
    Is it suitable for a single-phase network?
    This 4P model is designed for a three-phase 400 V network; for a single-phase circuit, choose the 2P version.
    Can automatic reclosing be disabled?
    Yes, it is switched on and off in the app.
    What cable is needed for a 63 A breaker?
    The cross-section is selected by the designer according to cable type, length and installation method – the cable's current-carrying capacity must be no less than 63 A.

    Smart circuit breaker | 4P | 63 A | C | 6 kA | 400 V AC | WiFi Tuya + RS485 | energy metering | residual current protection | GEYA GYRC-ZN01

    GEYA GYRC-ZN01 63 A – a three-phase smart circuit breaker with C curve, 6 kA breaking capacity, adjustable residual current, voltage and phase protection, energy metering, WiFi Tuya and RS485 control. Suitable for the supplies of homes, country houses, rental and commercial properties that need to be monitored and controlled remotely.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • privacy policy

    Information