- -163.32€

Smart flush-mounted CO2 sensor-controller | CO2 400-2000ppm | T 0…50°C | 0-95%rH | 0-10VDC/0-20mA/PWM | Modbus RTU | 85-264VAC | IP30 | Sentera Controls | FCMF8-R
Code: FCMF8-ROffer is valid until 2026-12-31Price 291.62 € VAT incl.( 241.01 € VAT excl. )454.94 €You save 163.32 €Want another price? Suggest yours! -
Smart flush-mounted CO2 sensor-controller | CO2 400-2000ppm | T 0…50°C | 0-95%rH | 0-10VDC/0-20mA/PWM | Modbus RTU | 85-264VAC | IP30 | Sentera Controls | FCMF8-R
FCMF8-R – a Sentera Controls smart flush-mounted CO2 sensor-controller that measures CO2 concentration (400–2000 ppm), temperature (0…+50 °C) and relative humidity (0–95 % rH) in the room and has one control output (0-10 VDC, 0-20 mA or PWM), which the integrated algorithm calculates from the highest of the T, rH and CO2 values. Supply – 85–264 VAC, 50–60 Hz.
Key idea:
This is demand-controlled ventilation “out of the box”: the sensor itself decides how much ventilation is needed and directly controls an EC fan, an AC speed controller or a damper actuator. Any of the three measured quantities can be disabled – e.g. to control by CO2 only.CO2 range
400–2000 ppmOutput
1 × 0-10 VDC / 0-20 mA / PWMPower supply
85–264 VAC, 50–60 HzProtection
IP30, indoors onlyOperating principle
The device is flush-mounted in a wall box or surface-mounted on the wall and connected directly to the mains (L, N; 85–264 VAC); output – Ao and GND, Modbus RTU – A, /B (with Cat5 or EIB cable).
The CO2 sensor, together with the temperature and humidity sensor, measures air quality (the CO2 sensor needs 2 min of warm-up to operate and 10 min for full accuracy), and all parameters are available over Modbus RTU. A range is set for each quantity, and the output (0–100 %) follows the highest of the three calculated values; the output type is 0-10 VDC (≥ 50 kΩ), 0-20 mA (≤ 500 Ω) or 1 kHz PWM (3.3 or 12 VDC), so it directly controls an EC fan, an AC fan speed controller or a damper actuator.
Result – ventilation according to the actual number of people and air quality: in an empty room ventilation runs at a minimum, and as people gather it increases, which reduces heating / cooling losses and fan energy consumption.
Benefits FCMF8-R?
CO2, temperature, humidity and a control algorithm in one device – demand-controlled ventilation without a separate controller or programming.Technical specifications
Product type Smart flush-mounted CO2 sensor-controller Manufacturer / code Sentera Controls / FCMF8-R Measured quantities CO2, temperature, relative humidity CO2 range 400–2000 ppm Temperature range 0…+50 °C Humidity range 0–95 % rH, non-condensing Accuracy ±0.4 °C (5…50 °C), ±0.8 °C (-20…50 °C); ±3 % rH (20–80 %), ±5 % rH (5–95 %); CO2 ±(45 ppm + 3 %) Outputs AO1 according to the highest of T / rH / CO2: 0-10 VDC (RL ≥ 50 kΩ) / 0-20 mA (RL ≤ 500 Ω) / PWM 1 kHz, 3.3 or 12 VDC Communication Modbus RTU (RS485); firmware update via Modbus RTU Supply voltage 85–264 VAC, 50–60 Hz Indication Red / yellow / green LED Installation Flush-mounted or surface-mounted Housing ABS plastic, white outside, black inside Protection class IP30 (EN 60529), indoor use only Storage temperature -10…+60 °C Weight 0.17 kg (net) Compliance LVD 2014/35/EU, EMC 2014/30/EU, WEEE 2012/19/EU, RoHS (EU) 2015/863 Manufacturer documentation
✔ Recommended by Elektrotechnikos sprendimaiOriginal manufacturer documentation – technical data, wiring diagrams and installation instructions.
Main functions
- Integrated algorithm – the output follows the highest of T, rH and CO2 – direct control of an EC fan, an AC controller or a damper.
- Parameters that can be disabled – can be controlled by CO2 only or any combination.
- Modbus RTU – all measurements and settings are accessible remotely.
- Firmware update – over the Modbus RTU network.
- LED indication – red – value out of range or sensor fault, yellow – danger zone, green – normal; the CO2 level is shown by default.
- Configuration – Configuration and monitoring – the free Sentera 3SModbus software (via the CNVT-USB-RS485 converter) or the Sensistant Modbus configurator.
Where is it used?
- Offices, meeting rooms, classrooms
- Kindergartens, schools, auditoriums
- Residential rooms and apartments
- Restaurants, gyms
- Demand-controlled ventilation with EC fans
- BMS and SenteraWeb systems
On-demand operation
For the apartment and house electrician.
The CO2 sensor-controller is powered directly from 230 V in a flush-mounted box, so no 24 V power supply is needed.For school and kindergarten renovation designers.
In a classroom, ventilation automatically intensifies as CO2 rises, and in an empty room it runs at the minimum.For restaurant and gym owners.
The fans run according to the actual number of people, so heating and electricity consumption fall.Practical application
If in a classroom only 230 V is available at the flush-mounted box and the ventilation EC fan has a 0-10 VDC input, then the FCMF8-R is connected directly to the mains and, as CO2 rises within the set 400–2000 ppm range, proportionally increases the fan speed.Application guide: how it is used in practice
The same FCMF8-R adapts to different sites – only what is connected to its outputs changes:
Site What is connected Result Installer's note Classroom, conference room AO1 0-10 VDC → EC fan control input The fan speeds up as CO2 rises; in an empty room – minimum T and rH can be disabled – control by CO2 only Room with a VAV / air damper AO1 → damper actuator 0-10 VDC input The damper opens in proportion to air quality Actuator input resistance ≥ 50 kΩ AC fan AO1 → analog input of an electronic or transformer controller AC fan speed according to CO2 Check the speed controller's input signal type Building with BMS Modbus RTU → A, /B Measurements and settings centralised A separate address for each device Apartment or office without 24 V supply L, N ← 230 VAC mains No separate power supply needed To be connected by a qualified electrician with the power disconnected How to choose a CO2 transmitter
Installation / output / power supply Recommended model Room, 3 separate outputs T / rH / CO2, 24 VDC, 4 wires RSMFF-3 (multifunction transmitter, -F) Room, 3 separate outputs T / rH / CO2, 24 VDC or 24 VAC, 3 wires RSMFG-3 (multifunction transmitter, -G) Room, 1 control output based on T / rH / CO2, 24 VDC RCMFF-3 (smart sensor, -F) Room, 1 control output, 24 VDC or 24 VAC RCMFG-3 (smart sensor, -G) Flush-mounted / surface-mounted, 1 output, powered from the 230 V mains FCMF8-R (85–264 VAC) ← this model Flush-mounted / surface-mounted, 1 output, 24 VDC or 24 VAC FCMFG-R (24 VAC/VDC) Duct, 1 control output based on T / rH / CO2, 24 VAC/VDC DCMFG-2R (smart duct sensor) Duct, NDIR CO2 + T + rH, Modbus RTU only DSCDG0-4 (no analog outputs) Duct, NDIR CO2 + T + rH, 3 analog outputs + Modbus RTU DSCDG3-4 (3 outputs) Rule: by installation location (wall, flush-mounting box, duct) and by what is needed: separate T / rH / CO2 signals for a controller or BMS (transmitter, 3 outputs), a single control signal directly to an EC fan or damper (smart sensor), or Modbus data only. Choose the supply according to the site's control circuit: -F – 24 VDC, 4-wire; -G – 24 VAC or 24 VDC, 3-wire; 8 – directly from the 230 V mains.When to choose another solution: for wall mounting – RCMF-3 series; for separate signals – RSMF-3 series; without CO2 – FCTH series; for a duct – DCMFG-2R.Pros
- CO2, temperature and humidity in one device
- Modbus RTU, firmware updated over the network
- Integrated control algorithm – no separate controller needed
- Power directly from the 230 V mains
- Flush-mounted or surface-mounted installation
Cons / limitations
- One control output – for separate signals choose a transmitter
- CO2 measuring range 400–2000 ppm – intended for indoor air quality, not for industrial gas monitoring
- IP30 – dry rooms only
Safety and installation notes
- Installation and connection are to be carried out by a qualified electrician / automation specialist with the power disconnected.
- Supply voltage – 85–264 VAC, 50–60 Hz.
- Hazardous mains voltage is present on terminals L, N – connect only with the power disconnected.
- Resetting the Modbus communication parameters – with a jumper on PROG pins 1 and 2 for at least 5 s.
- For indoor use only; do not install in direct sunlight.
Quick selection guide
CO2 400–2000 ppm0…+50 °C0–95 % rH0-10 VDC / 0-20 mA / PWM85–264 VAC, 50–60 HzIP30Suitable when you need:- to implement demand-controlled ventilation by CO2 level;
- to control an EC fan or damper directly from the sensor;
- to integrate air quality data into a BMS via Modbus RTU.
Check before use:- the input type of the controlled device;
- the supply: 85–264 VAC, 50–60 Hz;
- the installation location – an occupied zone, not near doors or windows.
Important reminder: The FCMF8-R measures CO2 to assess indoor air quality; it is not a gas leak or safety detector.FAQ
Does it measure VOC?
No, CO2, temperature and relative humidity are measured.Can it be controlled by CO2 only?
Yes, the temperature and humidity parameters can be disabled.What are the output signals?
One output 0-10 VDC, 0-20 mA or PWM and Modbus RTU.How are the settings changed?
Via Modbus RTU – the 3SModbus software with a CNVT-USB-RS485 converter, or via BMS.How do I reset the Modbus settings?
With a jumper on PROG contacts 1 and 2 for at least 5 seconds.Is a 24 V power supply unit required?
No, the FCMF8-R is powered directly from 85–264 VAC.Smart flush-mounted CO2 sensor-controller | CO2 400-2000ppm | T 0…50°C | 0-95%rH | 0-10VDC/0-20mA/PWM | Modbus RTU | 85-264VAC | IP30 | Sentera Controls | FCMF8-R
Sentera FCMF8-R – smart flush-mounted CO2 sensor-controller: CO2 400–2000 ppm, temperature 0…+50 °C, humidity 0–95 % rH, 0-10 VDC / 0-20 mA / PWM control output and Modbus RTU, 85–264 VAC, 50–60 Hz supply. For demand-controlled ventilation.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products