  • Soft starter | soft start device | 3-phase | 85A | 45kW | 200-440V | Danfoss | MCD 202-045-T4-CV3 | 5702427098558

    Code: MCD202045T4CV3
    Barcode: 5702427098558

    Danfoss VLT® Compact Starter MCD 202 – is a compact three-phase motor soft starter designed to reduce starting current peaks, mechanical stress and electrical network load during motor start-up. Model MCD202045T4CV3 is designed for 45 kW motors, has a rated current of 85A, operates with a 200-440VAC supply network and can be controlled by 110/240VAC or 440VAC control voltage. 

  • Danfoss VLT® Compact Starter MCD 202 soft starter – 45 kW, 85A, 3-phase, 200–440VAC, MCD202045T4CV3

    Danfoss VLT® Compact Starter MCD 202 – is a compact three-phase motor soft starter designed to reduce starting current peaks, mechanical stress and electrical network load during motor start-up. Model MCD202045T4CV3 is designed for 45 kW motors, has a rated current of 85A, operates with a 200–440VAC supply network and can be controlled by 110/240VAC or 440VAC control voltage.

    Main idea:
    This Danfoss MCD 202 soft starter is designed for smooth starting and stopping of three-phase electric motors when it is necessary to reduce mechanical shocks, voltage drops, starting current peaks and extend the service life of the motor and mechanical equipment.
    Power
    45 kW
    Rated current
    85A
    Supply
    3-phase, 200–440VAC
    Series
    VLT® Compact Starter MCD 202

    Operating principle

    The soft starter controls the motor start-up process by gradually increasing the voltage supplied to the motor. This reduces the instantaneous starting current, mechanical shocks and the load on belts, drives, pumps, fans and other mechanical assemblies.

    The Danfoss MCD 202 series is designed for simple and reliable motor starting. It supports 2-wire or 3-wire start/stop control, provides good starting performance and can be used with grounded delta power supply systems. This model belongs to the B-frame size and is intended for controlling 45 kW / 85A motors.

    Why is a soft starter useful?
    It helps protect the motor and mechanical equipment from sudden loads during start-up. Instead of an abrupt start, the motor starts more smoothly, which reduces stress on the electrical network, contactors, protection devices, bearings, drives and technological equipment.

    Technical parameters

    Manufacturer Danfoss
    Series VLT® Compact Starter MCD 200
    Model MCD202045T4CV3
    Product / order code 175G5215
    Product type Soft starter
    Power 45 kW
    Rated current 85A
    Number of phases Three-phase
    Main supply voltage 200–440VAC
    Control voltage 110/240VAC or 440VAC
    Frame size B-Frame
    MCD series 202
    Power rating marking 045 – 45 kW, 85A
    Phase marking T – Three phase
    Mains voltage marking 4 – 200–440VAC
    Control supply voltage marking CV3 – 110/240VAC or 440VAC
    Start control 2-wire or 3-wire start/stop control
    Standard starting duty 4 x Ie up to 6 seconds
    Heavy-duty start 4 x Ie up to 20 seconds
    Compatibility Compatible with grounded delta power supply systems
    Gross weight 4.9 kg
    Net weight 4.3 kg

    Where is it used?

    • In pump systems – water supply, circulation, drainage or industrial pumps.
    • In fans and air supply systems – when starting loads need to be reduced.
    • In conveyors and transport systems – for smoother start-up of mechanisms.
    • In compressors – for reducing motor starting current and mechanical stress.
    • In industrial equipment – production lines, technological assemblies and electrical panel systems.

    Practical installation example

    For example, a 45 kW three-phase pump is started through a Danfoss MCD 202 soft starter. Instead of an abrupt start, the device gradually increases the motor voltage, reducing the starting current peak, hydraulic shock in the pipeline and mechanical load on the pump drive.

    This solution is especially useful in facilities where motors are started frequently or where the electrical network is sensitive to high starting current peaks.

    Use according to need

    For electricians: a suitable solution for installing motor control panels, pump stations, ventilation units or industrial equipment when smooth starting of a three-phase motor is required.

    For engineers / designers: suitable for designing electric drive systems where it is necessary to limit starting current, reduce mechanical shocks and improve motor start control.

    For maintenance specialists: useful when replacing old starting solutions, reducing mechanical stress on contactors, belts, bearings, drives and pumps.

    Pros

    • 45 kW / 85A power – suitable for larger three-phase motors.
    • 200–440VAC supply – wide mains voltage range.
    • 2-wire or 3-wire start/stop control – more flexible integration into control circuits.
    • Smoother motor start – lower current peaks and mechanical shocks.
    • Heavy-duty start up to 4 x Ie / 20 s – suitable for more demanding starting modes.
    • Danfoss VLT® series – a well-known industrial automation manufacturer.
    • Compatible with grounded delta systems – wider application in industry.
    • Compact B-frame – more convenient installation in electrical panels.

    Cons / limitations

    • Not a frequency inverter – the device is intended for starting, not for continuous motor speed control.
    • Must be selected according to the motor and load – motor power, current and starting mode must be evaluated.
    • Control voltage must match the circuit – before connection, 110/240VAC or 440VAC control must be checked.
    • Not suitable for single-phase motors – intended for three-phase systems.
    • Qualified installation is required – incorrect connection may damage the equipment or cause danger.

    Safety and installation notes

    The soft starter is an industrial electric drive control component. Its selection and installation must be carried out according to the motor rated data, load type, electrical network parameters and manufacturer documentation.

    • Installation must be carried out by a qualified electrician or automation specialist.
    • Before work, the electrical supply must be disconnected and the absence of voltage must be checked.
    • Rated parameters must not be exceeded – 45 kW, 85A and the specified voltage limits.
    • The control voltage must be checked – 110/240VAC or 440VAC according to the specific circuit.
    • The starting mode must be evaluated – standard start, heavy-duty start, starting frequency and load type.
    • Suitable protection devices must be used – fuses, circuit breakers, contactors and motor protection solutions according to the project.
    • Before start-up, the motor nameplate must be checked and compatibility with the soft starter must be verified.

    Quick selection guide

    Choose Danfoss MCD202045T4CV3 when you need to start a 45 kW three-phase motor and want to reduce starting current, mechanical loads and electrical network disturbances. This is a suitable solution for pumps, fans, conveyors, compressors and other industrial drives.

    Model
    MCD202045T4CV3
    Power
    45 kW
    Current
    85A
    Supply
    3-phase, 200–440VAC
    Suitable when you need to:
    • smoothly start a 45 kW three-phase motor;
    • reduce starting current peaks;
    • protect pumps, fans, conveyors or drives from mechanical shocks;
    • use 2-wire or 3-wire start/stop control;
    • install a reliable soft starter in an industrial electrical panel.
    Check before installation:
    • whether the motor power and current match the 45 kW / 85A parameters;
    • whether the mains voltage is within the 200–440VAC range;
    • whether the control circuit voltage corresponds to 110/240VAC or 440VAC;
    • whether the load is not too heavy for the selected starting mode;
    • whether sufficient ventilation and protection devices are provided in the electrical panel.
    Important reminder:
    This device is a soft starter, not a frequency inverter. It is designed to control the motor start-up process, but it is not intended for continuous motor speed regulation during operation.

    FAQ – frequently asked questions

    What is Danfoss MCD202045T4CV3 used for?
    It is intended for soft starting of 45 kW three-phase electric motors when it is necessary to reduce starting current and mechanical shocks.
    Does this device regulate motor speed?
    No. It is a soft starter, not a frequency inverter. It is designed for smooth starting and reduction of starting loads, but it is not intended for continuous speed regulation.
    What is the rated current of this model?
    The rated current of this model is 85A.
    What mains voltage is this soft starter designed for?
    The model is designed for a three-phase 200–440VAC supply network.
    What control voltage is used?
    According to the CV3 model marking, the control voltage is 110/240VAC or 440VAC. Before connection, the specific circuit and documentation must be checked.
    In which equipment is it most commonly used?
    It is most commonly used for pumps, fans, conveyors, compressors and other industrial three-phase drives.

    Reliable Danfoss soft starter for 45 kW three-phase motors

    Danfoss VLT® Compact Starter MCD 202 MCD202045T4CV3 is a professional soft starting solution for industrial motors when it is necessary to reduce starting current, mechanical shocks and electrical network load.

    Thanks to its 45 kW power, 85A rated current, 200–440VAC three-phase supply, 2-wire or 3-wire start/stop control and the reliability of the Danfoss VLT® MCD series, this device is suitable for starting systems of pumps, fans, conveyors, compressors and other industrial drives.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.