Strap-on pipe temperature transmitter | 0-85°C | Modbus RTU | 24VDC PoM | RJ45 | IP65 | Sentera Controls | DTP-M
Code: DTP-MOffer is valid until 2026-12-31Price 40.55 € VAT incl.( 33.51 € VAT excl. )63.26 €You save 22.71 €Want another price? Suggest yours!-
Strap-on pipe temperature transmitter | 0-85°C | Modbus RTU | 24VDC PoM | RJ45 | IP65 | Sentera Controls | DTP-M
DTP-M – a Sentera Controls digital strap-on (pipe-mounted) temperature transmitter with Modbus RTU (RS485) communication. It measures water pipe temperature of 0…+85 °C with ±1 °C accuracy and is powered by 24 VDC via Modbus (PoM) through the RJ45 socket.
Key idea:
Pipe temperature without a thermowell and without breaking into the piping: the sensor is pressed against the pipe, and the temperature travels over the Modbus RTU network to the controller or BMS.Measuring range
0…+85 °C, ±1 °CCommunication
Modbus RTU (RS485)Power supply
24 VDC via Modbus (PoM), RJ45Protection
IP65, includedOperating principle
The transmitter is attached to the pipe with the supplied heat-resistant 300 × 4.8 mm cable tie; the copper plate improves heat transfer, and the thermal pad (19 × 14 × 1.5 mm) ensures good contact with the pipe surface. A cable with the 24 VDC supply and Modbus RTU signals (A, /B, GND) is connected to the RJ45 socket.
Temperature is measured within 0…+85 °C with ±1 °C accuracy and provided in Modbus registers; the left green LED shows power, and the blinking green LEDs show active Modbus communication.
Result – pipework temperature in the BMS or controller without a thermowell and without draining the system. The sensor measures the pipe wall temperature: it is close to the water temperature when the pipe is metal and the sensor location is insulated; on plastic pipes the readings are less accurate.
Benefits DTP-M?
Installation without dismantling the piping and without a thermowell, with power and data in a single RJ45 cable.Technical specifications
Product type Strap-on pipe temperature transmitter with Modbus RTU Manufacturer / code Sentera Controls / DTP-M Measuring range 0…+85 °C Accuracy ±1 °C Communication Modbus RTU (RS485) Power supply 24 VDC via Modbus (PoM) Energy usage Max. 0.192 W; Imax 8 mA Connection RJ45 (8 pins): +24 VDC, A, /B, GND Thermal contact Copper plate, thermal pad 19 × 14 × 1.5 mm Mounting Heat-resistant cable tie 300 × 4.8 mm (included) Indication Green LED – power; blinking green LEDs – Modbus communication Protection class IP65 Operating environment -30…+85 °C, 5–95 % rH non-condensing Weight 0.024 kg (net) Compliance EMC 2014/30/EU (EN 61326-1, EN 61326-2-3), WEEE 2012/19/EU, RoHS 2011/65/EU Manufacturer documentation
✔ Recommended by Elektrotechnikos sprendimaiOriginal manufacturer documentation – technical data, wiring diagrams and installation instructions.
Main functions
- Modbus RTU (RS485) – the temperature is read by a controller, BMS or SCADA.
- Power over Modbus – 24 VDC over the same RJ45 cable.
- Copper plate and thermal pad – good thermal contact with the pipe.
- Series resistor included – 300 × 4.8 mm, heat-resistant – installation without additional parts.
- Range 0…+85 °C – covers heating and hot water circuit temperatures.
- Low costs – up to 0.192 W (Imax 8 mA) from the PoM line.
- LED indication – power and communication status.
- IP65 – suitable for technical rooms and heat substations.
Where is it used?
- Supply and return water monitoring of heating circuits
- Water heating coil piping in ventilation units
- Heat substations and boiler rooms
- Heat pump systems
- Hot water preparation circuits up to +85 °C
- Modernization of existing systems without dismantling the piping
- BMS pipework temperature monitoring
On-demand operation
For heating installers.
No thermowell or piping dismantling needed – the transmitter is secured with a cable tie.For heat pump installers.
Two DTP-M units on the supply and return pipes give the temperature difference in the Modbus network.For building energy managers.
Pipework temperatures in the BMS help evaluate the efficiency of heating circuits.Practical application
If the return water temperature of a running heating circuit has to be added to the BMS without draining the water, then the DTP-M is clamped with a cable tie to the metal pipe, the spot is insulated, and the 0…+85 °C temperature is passed over the Modbus RTU network with ±1 °C accuracy.Application guide: how it is used in practice
The DTP-M is placed on the pipe, and the temperature travels over the Modbus RTU network:
Site What is connected Result Installer's note Water heating coil DTP-M on the return water pipe → Modbus The controller monitors the return water temperature Insulate the transmitter location Heating circuit DTP-M on the supply pipe → DPOM8-24-20 → BMS Supply water temperature in the BMS Metal pipe – more accurate readings Heat pump Two DTP-M on the supply and return pipe Temperature difference for evaluating system efficiency Different Modbus addresses Retrofit without dismantling DTP-M instead of an immersion sensor No need to drain the water or install a thermowell Clean the pipe surface How to choose a Modbus temperature transmitter
Installation location / probe Recommended model Duct, 85 mm probe DTS-M-080 (duct, 85 mm) Duct, 165 mm probe DTS-M-160 (duct, 165 mm) Water pipe, strap-on DTP-M (pipe, 0–85 °C) ← this model DTS-M wall fixing DTS-MB-BK-ASM (bracket) Rule: for water pipes – DTP-M (0…+85 °C) is attached; for air ducts – DTS-M-080 or DTS-M-160 depending on the duct size.When to choose another solution: passive sensors for controllers with a PT input – TUTSN (duct), ROTSN (room), FLTSN (with cable); for power and the Modbus line – DPOM8-24-20 (Power over Modbus module with a repeater).Pros
- Installation without a thermowell and without dismantling the piping
- Modbus RTU
- 24 VDC Power over Modbus
- RJ45 connector
- IP65
- Series resistor and thermal pad included
Cons / limitations
- Accuracy ±1 °C
- Measures the pipe surface temperature, not the water temperature directly
- No analog output – a Modbus controller is required; for a controller with a PT input choose the FLTSN series with a thermowell
- Range up to +85 °C
- A 24 VDC Modbus power supply is required – the DPOM8-24-20 is intended for this
Safety and installation notes
- Installation and connection are to be carried out by a qualified installer with the power disconnected.
- Power supply 24 VDC only, via Modbus.
- Do not exceed a pipe temperature of +85 °C.
- Keep the cable away from hot surfaces.
Quick selection guide
Modbus RTU24 VDC PoMRJ450…+85 °CIP65Suitable when you need:- to measure water pipe temperature on a Modbus RTU network;
- to install a sensor without a thermowell;
- to reduce the number of wires with Power over Modbus.
Check before use:- whether the pipe temperature does not exceed +85 °C;
- whether there is a Modbus RTU controller and 24 VDC PoM power;
- the pipe material (metal – more accurate readings).
Important reminder: The DTP-M has no PT or 0-10 VDC output – it works only on a Modbus RTU network.FAQ
Is a thermowell needed?
No, the transmitter is attached to the pipe surface and secured with a cable tie.What is the measuring range?
The transmitter measures 0…+85 °C with ±1 °C accuracy.How is the transmitter powered?
It is powered at 24 VDC over Modbus (PoM) via the RJ45 socket.Can it be used in a duct?
No, for ducts the DTS-M-080 and DTS-M-160 are intended.Is it suitable for a plastic pipe?
Suitable, but the readings will be less accurate than on a metal pipe.Does the measuring point need to be insulated?
Yes, an insulated location gives readings closer to the true water temperature.Strap-on pipe temperature transmitter | 0-85°C | Modbus RTU | 24VDC PoM | RJ45 | IP65 | Sentera Controls | DTP-M
Sentera DTP-M – strap-on pipe temperature sensor 0…+85 °C with Modbus RTU, 24 VDC Power over Modbus supply via RJ45, copper plate and IP65.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review