Supply air ventilation damper in wall | with G3 filter | aluminium grille with mesh | D125 | 0,5m | white | 12,5TOV-05
Code: 09575Price 29.63 € VAT incl.( 24.49 € VAT excl. )Wall-mounted supply air vent D125 with a 500 mm insulated duct, G3 filter and adjustable diffuser. Outdoor side – aluminium outdoor grille with mosquito mesh. Intended for controlled air inflow in rooms with forced exhaust.
-
Supply air ventilation damper in wall | with G3 filter | aluminium grille with mesh | D125 | 0,5m | white | 12,5TOV-05
Wall-mounted supply air vent (damper) D125 – a plastic duct with thermal and acoustic insulation and a G3 filter, closed indoors by a decorative air supply control device (diffuser) and outdoors by the outdoor element (aluminium outdoor grille with mosquito mesh). Duct length 500 mm, cut to the wall thickness.
Key idea:
The vent supplies outdoor air to residential and office rooms and is best suited where forced exhaust is in operation: an exhaust fan or central exhaust system creates a slight negative pressure, and the vent provides controlled make-up air. This way air is not drawn in through window gaps and door cracks.Diameter
D125 (outer 129 mm)Duct length
500 mmOutdoor part
aluminium grille with meshFilter
G3, washableOperating principle
A hole is drilled with the nearest larger core bit than the duct outer diameter (129 mm), with a 2–3° slope outwards for condensate drainage. The duct is cut to the wall thickness, the insulation is pulled back from the cut and the duct is inserted.
The outdoor element – aluminium outdoor grille with mosquito mesh – is mounted outside, and indoors the decorative air supply control device (diffuser, Ø197 mm) is fixed with 4 dowels and screws. The filter is slid towards the room close to the head so it does not prevent inserting the diffuser.
When exhaust is running, outdoor air flows through the duct, the G3 filter and the diffuser into the room. The diffuser adjusts the amount of supply air, and the insulation reduces heat loss and street noise.
What does the 12,5TOV-05 vent give you?
A simple make-up air point that works without electricity for systems with forced exhaust: air comes in where planned, passes the filter, and the outdoor side is selected to suit the façade – in this model it is aluminium grille with mesh.Technical specifications
Product type Supply air ventilation damper (wall vent) Product code 12,5TOV-05 Nominal diameter D125 Duct inner / outer diameter 125 / 129 mm Duct length 500 mm (cut to wall thickness) Indoor element Decorative air supply control device (diffuser), Ø197 mm, white Outdoor element aluminium outdoor grille with mosquito mesh, size Ø150 mm Filter G3 class, washable with water Insulation Thermal and acoustic insulation element in the duct Throughput, fully open 61.0 m³/h at 1.5 m/s · 81.4 m³/h at 2 m/s · 122.1 m³/h at 3 m/s air velocity in the duct Wall opening Nearest core bit larger than 129 mm, 2–3° slope outwards Recommended system With forced exhaust Scope of delivery Diffuser, filter, insulating element, plastic duct, outdoor element Main functions
- Make-up air supply – delivers outdoor air where the exhaust draws it from – without drafts through window gaps.
- Adjustable diffuser – adapt the supply air amount to the room and season.
- G3 filter – captures dust, fluff and insects; washable with water.
- Thermal and acoustic insulation – reduces cooling of the duct walls and street noise.
- Aluminium grille – the duct is closed outdoors by an aluminium grille with mosquito mesh.
- Cuttable duct – the 500 mm duct is cut to the actual wall thickness.
Where is it used?
- Apartments and houses with exhaust fans in bathroom and kitchen
- Buildings with a central forced exhaust system
- Living rooms and bedrooms
- Offices and studies
- Apartment blocks under renovation
- Rooms lacking air inflow after window replacement
- Country and private houses
Use by need
For the ventilation installer.
A make-up air point for an exhaust system – D125 duct, standard drilling, several outdoor element options.For the homeowner.
A bathroom exhaust fan only works effectively when air has somewhere to come from – the vent ensures this.For the architect and façade contractor.
Choose the outdoor part to suit the façade: ASA plastic, stainless steel or aluminium on the same D125 duct.Practical use
If exhaust fans run in the bathroom and kitchen, but after window replacement doors are hard to close, whistling is heard through gaps and windows fog up, a 12,5TOV-05 vent installed in a living room gives air a controlled path: in the upper third of the window height, 20–30 cm from the reveal, with a 2–3° slope outwards.Pros
- Simple make-up air supply without electricity
- G3 filter, washable with water
- Thermal and acoustic insulation in the duct
- Flow adjustable with the diffuser
- Aluminium grille on the outdoor side
- Duct cut to wall thickness
- Series available in D100, D125, D160 and 500 / 1000 mm lengths
Cons / limitations
- Works best with forced exhaust – without it, flow depends on the weather
- No heat recovery – outdoor-temperature air is supplied in winter
- G3 is a coarse filter, not intended for fine particles (PM2.5)
- Duct 500 mm – for a thicker wall choose the 1000 mm version (TOV1)
Safety and installation notes
- Before drilling, check the wall for electrical cables, pipes and reinforcement.
- Drill with a 2–3° slope outwards – otherwise condensate will run into the room.
- Do not install close to the window reveal or at the junction of two external walls – the wall is coldest there, freezing and condensation may occur.
- Recommended position – upper third of the window height, 20–30 cm from the reveal; above the window only if the diffuser fits between lintel and ceiling.
- Leave free space above the diffuser for air movement.
- Mount the outdoor grille with louvres horizontal, ideally under a canopy, window sill or eave – so water does not enter the duct.
- In apartment blocks, agree façade drilling with the building administrator or owners’ association.
Quick selection guide
D125Duct 500 mmAluminium grilleG3 filterWith forced exhaustSuitable when you need:- Make-up air for exhaust fans
- Air inflow after window replacement
- A supply point without electricity or ductwork
Check before use:- Wall thickness – not more than 500 mm
- Whether exhaust is running (bathroom, kitchen, central system)
- Which outdoor element suits the façade
- Whether façade drilling is allowed (approval in apartment blocks)
Important reminder: The vent does not replace exhaust ventilation or a heat recovery unit – it only supplies air and does not recover heat.FAQ
How does 12,5TOV-05 differ from other versions in the series?
By the outdoor element: no suffix – ASA plastic grille, -02 – ASA plastic wall outlet, -04 – stainless steel outlet with mesh, -05 – aluminium grille with mesh.What hole size should be drilled?
The nearest core bit larger than the duct outer diameter (129 mm), with a 2–3° slope outwards.Will the vent work without an exhaust fan?
It will work naturally, but flow will depend on the weather – it works most steadily with forced exhaust.How is the vent maintained?
Wash the filter behind the diffuser every 3 months, vacuum the duct every 6 months and clean the grille once a year.Can the duct be shortened?
Yes – the 500 mm duct is cut to the wall thickness after pulling the insulation back from the cut.What is included?
Diffuser, G3 filter, insulating element, plastic duct and outdoor element.Supply air ventilation damper in wall | with G3 filter | aluminium grille with mesh | D125 | 0,5m | white | 12,5TOV-05
12,5TOV-05 – wall-mounted supply air vent D125 with a 500 mm insulated duct, G3 filter, diffuser and outdoor element (aluminium grille with mesh). Intended for controlled air inflow in residential and office rooms with forced exhaust.
Published: 2026-11-04 · Data verified against the manufacturer datasheet: 2026-11-04
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Window trickle vent | adjustable | with G3 filter | 350 mm | white | no-drill installation | 350LVBCode: 37611350LVB – adjustable supply window trickle vent with G3 (EU3) filter: 350 mm long, 17.9 mm wide, white. Mounted on the sash of a PVC or wooden window without drilling the frame, fully closable with a slider.
Price 25.41 € VAT incl.( 21.00 € VAT excl. )