    Promfactor Baltic FRT11 – a modular electronic temperature controller (thermostat) with an external NTC sensor, designed to control heating equipment, underfloor heating and other temperature maintenance systems. The temperature can be adjusted within the −5...+40 °C range, power supply – 24–240 V AC/DC, relay contact – up to 16 A. The thermostat is mounted on a 35 mm DIN rail and features adjustable hysteresis, LED indication and a 2.5 m NTC sensor cable. 

  • Modular thermostat | temperature controller | relay | −5...+40 °C | 16 A | 24–240 V AC/DC | DIN | IP20 | Promfactor Baltic | FRT11 | 4772151003099

    Promfactor Baltic FRT11 is a modular electronic temperature controller with an external NTC sensor, designed for automatic control of heating equipment, electric underfloor heating and other temperature maintenance systems. The controller allows the required temperature to be set from −5 °C to +40 °C and the hysteresis to be adjusted so that connected equipment is switched on or off according to the measured temperature. A wide 24–240 V AC/DC supply range, 16 A changeover relay contact, LED status indicators and installation on a standard 35 mm DIN rail allow the device to be integrated into electrical automation panels in residential, commercial and industrial installations.

    Key point:
    An electric heating system should not operate continuously simply because its power supply is switched on. When the temperature reaches the set limit, heating must stop, and when it falls, heating must start again. FRT11 automates this process: the external NTC sensor measures the temperature at the selected location, while the controller installed on the DIN rail controls the relay contact. Adjustable hysteresis allows the temperature switching limits to be selected, reducing unnecessary frequent contact switching.

    ⚡ Spark: Phase, why do I need a separate thermostat in the electrical panel if the heater can simply be switched on and off with a switch?

    ⚙ Phase: A switch does not know the temperature. FRT11 measures it through the NTC sensor and automatically controls the heating circuit. You set the required temperature, adjust the hysteresis and the system responds to temperature changes without continuous manual switching. In addition, the thermostat remains in the electrical panel, while the sensor can be installed where the temperature actually needs to be measured.

    Temperature adjustment
    −5...+40 °C
    Relay contact
    1 C/O | 16 A / 250 V AC
    Supply voltage
    24–240 V AC/DC
    Temperature sensor
    NTC | 2.5 m cable

    Operating principle

    The FRT11 temperature control system consists of an electronic controller, an electromagnetic output relay and an external NTC temperature sensor. NTC (Negative Temperature Coefficient) is a temperature-sensitive resistor whose electrical resistance decreases as temperature rises. The microcontroller evaluates changes in sensor resistance and determines the measured temperature accordingly.

    The required temperature is set using the device potentiometer. In heating control mode, when the temperature falls below the set switch-on threshold, the controller can switch on the heating equipment via the relay contact. When the switch-off threshold is reached, the relay state changes and heating stops. The exact contact operation depends on whether the NC or NO contact is used and on the original wiring diagram.

    Additional hysteresis adjustment allows the temperature difference between switching states to be set. This is important because without sufficient hysteresis the system could switch the heater on and off too frequently due to minor temperature fluctuations.

    For example, if a temperature of approximately +22 °C is required, correctly selected hysteresis allows the heating to operate within a certain temperature range instead of attempting to maintain an absolutely constant value at every moment. Exact switch-on and switch-off points are determined by the FRT11 hysteresis characteristic and control circuit.

    The controller has one changeover contact (1 C/O), so either the normally open (NO) or normally closed (NC) contact can be used according to the specific wiring diagram. LED indicators help monitor the supply and relay status. The device occupies the width of two standard DIN modules.

    Why is this temperature controller useful?
    FRT11 allows temperature maintenance to be automated without continuous manual control of the heating equipment. The external NTC sensor measures the temperature at the selected location, adjustable hysteresis helps control switching frequency, and the universal supply range allows the thermostat to be used in automation systems with different voltages. All control equipment is neatly installed in the electrical panel.

    Technical data

    Product type Modular electronic temperature controller / thermostat
    Brand Promfactor Baltic
    Model FRT11
    EAN code 4772151003099
    Control technology Microcontroller-controlled electronic thermostat
    Supply voltage 24–240 V AC/DC
    Rated frequency 50/60 Hz (for AC supply)
    Supply terminals A1, A2
    Temperature adjustment range −5...+40 °C
    Hysteresis adjustment range −0.5...+3 °C (according to product characteristic marking)
    Temperature setting By potentiometer
    Hysteresis setting By potentiometer
    Temperature measurement terminals T1, T2
    Temperature sensor type NTC thermistor
    Sensor dimensions Ø6 × 50 mm
    Sensor cable length 2.5 m
    Sensor cable conductors 2 × 0.5 mm²
    Sensor cable insulation High-temperature-resistant PVC
    Output contact configuration 1 C/O (one changeover contact)
    Maximum specified contact current 16 A
    Rated contact voltage 250 V AC
    Switching capacity (AC-1) Up to 4000 VA under the specified rated conditions
    Specified DC switching capacity 300 W; permissible DC voltage and current must be checked according to the contact characteristic
    Electrical endurance 100,000 switching operations (10⁵)
    Mechanical endurance 1,000,000 switching operations (10⁶)
    Status indication LED – power and relay status indicators
    Installation On 35 mm DIN rail (TH35)
    Number of enclosure modules 2 DIN modules
    Connectable conductor cross-section 0.5–2.5 mm²
    Terminal tightening torque 0.5 Nm
    Operating ambient temperature −5...+40 °C
    Storage temperature −10...+50 °C
    Degree of protection IP20
    Pollution degree 3
    Maximum specified installation altitude 2000 m above sea level
    Standards EN/IEC 60730-1; EN/IEC 60730-2-7

    Main functions

    • Automatic temperature control – controls connected equipment according to the set temperature and NTC sensor measurement.
    • Temperature range from −5 °C to +40 °C – allows the required setting for different heating and temperature maintenance systems to be selected.
    • Adjustable hysteresis – allows the difference between switch-on and switch-off thresholds to be adapted, reducing unwanted frequent relay switching.
    • External NTC temperature sensor – temperature is measured at the sensor location, not only inside the electrical panel.
    • 2.5 m sensor cable – allows the sensor to be installed away from the controller mounted on the DIN rail.
    • 1 C/O changeover contact – allows a normally open or normally closed control contact to be used according to the selected wiring diagram.
    • Up to 16 A contact load – allows electrical loads of suitable power to be controlled, taking into account the type of load.
    • Universal 24–240 V AC/DC supply – simplifies integration into automation systems with different voltages.
    • LED status indication – allows the controller power and relay status to be visually monitored.
    • DIN-rail installation – no separate wall-mounted thermostat enclosure is required.

    Where is it used?

    • In electric underfloor heating systems – for maintaining the temperature measured in the floor or another selected location.
    • In control circuits for electric convectors and other heaters.
    • In heating automation panels of residential buildings.
    • In temperature control systems for administrative and commercial premises.
    • In heating systems for warehouses, workshops and utility rooms.
    • In electrical and automation cabinets where control according to the temperature measured by an external sensor is required.
    • In industrial equipment temperature maintenance circuits where thermostatic ON/OFF control is sufficient.
    • In frost-protection systems, provided that the selected control characteristic and additional protective measures correspond to the intended application.

    Use according to need

    For the electrical installer.
    One modular controller in the electrical panel and an external NTC sensor at the temperature measurement point. Universal supply and a 1 C/O contact simplify integration into different control circuits.
    For the underfloor heating installer.
    Switching electric underfloor heating on and off can be automated according to the sensor temperature. The adjustment range and hysteresis are selected according to the requirements of the floor covering and heating system.
    For the automation designer.
    FRT11 can be used as a temperature-controlled relay element through which a load or contactor coil is controlled. For larger loads, load switching is separated from the thermostat relay.

    Practical application

    When installing electric underfloor heating in a small dry utility room, the FRT11 can be mounted in the electrical distribution panel while the NTC temperature sensor is installed at the intended floor temperature measurement location. The required temperature is set on the controller, for example +25 °C, if such a value is permitted for the specific floor covering and heating system. As the temperature changes, the controller operates the relay contact and accordingly the heating circuit. If the heating load exceeds the permissible limits of the thermostat contacts, a properly selected contactor is used. In this way, the temperature is maintained automatically without manually switching the heating on and off.

    Advantages

    • Wide 24–240 V AC/DC supply range.
    • Temperature adjustment from −5 °C to +40 °C.
    • Adjustable hysteresis that helps reduce switching frequency.
    • External NTC sensor with 2.5 m cable.
    • One 1 C/O changeover relay contact.
    • Up to 16 A contact current under suitable load conditions.
    • LED power and relay status indication.
    • Convenient installation on a 35 mm DIN rail.
    • Compact two-DIN-module enclosure.
    • Up to 1,000,000 mechanical switching operations.

    Limitations

    • IP20 – the controller itself is not suitable for open installation in damp areas or outdoors.
    • The 16 A contact current limits the size of directly connected loads.
    • Lower contact load limits may apply to inductive loads.
    • No digital temperature display.
    • Temperature is adjusted with potentiometers rather than programmed using a weekly schedule.
    • The standard sensor cable is 2.5 m long; permissible conditions must be checked before extending it.
    • One relay output – not a controller for several independent temperature zones.

    Installation and safety notes

    • Installation must be carried out by a qualified electrical specialist. Before connection work, switch off the power supply and verify the absence of voltage.
    • DIN installation. The controller is mounted on a 35 mm DIN rail in a suitable electrical or automation panel. The enclosure occupies two DIN modules.
    • Supply terminals A1 and A2. The supply voltage must be within the 24–240 V AC/DC range. Connection must follow the wiring diagram of the specific product.
    • Sensor connection. The NTC temperature sensor is connected to measurement terminals T1 and T2. The sensor circuit must be installed according to the product instructions, separating it from potential interference sources and hazardous-voltage conductors as required.
    • Output contacts. The thermostat supply terminals are not the same as the load relay contacts. The functions of NO, NC and common contacts must be checked according to the original contact marking.
    • Maximum contact current – 16 A. Permissible load depends on the type of load. For heating elements, contactors, motors and other equipment, the corresponding utilisation category must be taken into account.
    • High-power loads. If the load exceeds the permissible relay limits, use an external contactor or another suitable power switching device.
    • Underfloor heating sensor location. The sensor must be installed according to the installation requirements of the heating system and floor covering. Do not rely only on the thermostat temperature range without considering the maximum permissible floor temperature.
    • Sensor cable length – 2.5 m. Unauthorised extension of the cable may alter measurement conditions or increase the effect of electromagnetic interference.
    • Conductor cross-section – 0.5–2.5 mm². Tighten the terminals to 0.5 Nm using suitable conductors and tools.
    • IP20. Install the controller in a panel suitable for the environmental conditions. IP20 does not provide protection against water.
    • Independent protection. FRT11 is not a circuit breaker, residual current device or universal protective temperature limiter. Where overheating protection is required, it must be provided separately.
    • Operating temperature. The ambient temperature inside the electrical panel must remain within −5...+40 °C.
    ⚡ Phase tip:
    A common temperature-control mistake is installing the NTC sensor where the temperature does not represent the zone being controlled. For example, with underfloor heating the sensor must be installed in the correct position within the floor structure, not next to a heat source or in a random cavity. Also, do not confuse the 16 A contact rating with a universal ability to switch any 16 A load: motors, transformers and other inductive loads require a separate evaluation of contact loading.

    Quick selection guide

    −5...+40 °C
    16 A | 1 C/O
    24–240 V AC/DC
    NTC | DIN | IP20
    Suitable when you need:
    • temperature control in an electrical distribution panel
    • heating equipment to be switched on and off according to an NTC sensor
    • adjustable hysteresis for the temperature control system
    • universal 24–240 V AC/DC supply
    • one changeover contact for controlling a heating circuit or contactor
    Check before buying:
    • whether the required temperature adjustment range fits within −5...+40 °C
    • whether the 2.5 m NTC sensor cable is sufficient to reach the installation location
    • whether the controlled equipment current and load category are compatible with the relay contacts
    • whether simple ON/OFF control rather than a programmable temperature schedule is required
    • whether there is space for two DIN modules in the electrical panel
    • whether suitable overload and short-circuit protection is provided
    Important reminder: 24–240 V AC/DC is the thermostat supply voltage range, while 16 A / 250 V AC describes the rating of its output contacts. These are different electrical parameters. Relay contacts must not be loaded beyond the current, voltage and switching capacity limits permitted for the specific load category.

    FAQ – Spark asks, Phase answers

    ⚡ Spark: Can FRT11 directly control electric underfloor heating?
    ⚙ Phase: Yes, if the heating circuit load is within the permissible limits of the thermostat relay contacts and the required electrical protection is installed. If the heating power is too high, FRT11 can be used to control a contactor, while the load is switched through the contactor power contacts.
    ⚡ Spark: What does an NTC temperature sensor mean?
    ⚙ Phase: NTC is a temperature-sensitive resistor whose resistance decreases as temperature rises. FRT11 measures the change in sensor resistance and controls the relay accordingly. Sensor dimensions are Ø6 × 50 mm and cable length is 2.5 m.
    ⚡ Spark: Why is hysteresis adjustment needed?
    ⚙ Phase: Hysteresis defines the temperature difference between relay switching thresholds. It prevents the heater from switching on and off continuously due to very small temperature fluctuations. Greater hysteresis generally means less frequent switching but a wider temperature variation.
    ⚡ Spark: Does the thermostat require 230 V?
    ⚙ Phase: No. The FRT11 supply range is 24–240 V AC/DC. This means the controller can be powered from systems with different voltages within the permissible limits. However, relay contact load parameters must be evaluated separately from the supply voltage.
    ⚡ Spark: What is the difference between NO and NC relay contacts?
    ⚙ Phase: NO is normally open and NC is normally closed. FRT11 has one 1 C/O changeover contact. Its states are used according to the selected control circuit and relay operating logic. The original terminal marking must be followed during installation.
    ⚡ Spark: Does 16 A mean that any 3.5 kW heater can be connected?
    ⚙ Phase: Not automatically. 16 A is the contact rating, but the actual permissible load depends on its type. Resistive loads are assessed under the AC-1 category, while motors and other inductive loads may require different contact ratings. A separate contactor is often used for higher-power loads.
    ⚡ Spark: Can the NTC sensor cable be extended?
    ⚙ Phase: The standard cable length is 2.5 m. The possibility of extension must be assessed according to the product instructions, permissible conductor resistance and electromagnetic interference conditions. Incorrect extension of the sensor cable may affect temperature measurement accuracy.
    ⚡ Spark: Can this thermostat be installed outdoors or in a damp room?
    ⚙ Phase: The FRT11 itself has an IP20 degree of protection, so it is not intended for direct exposure to water. If used in a more demanding environment, a suitably selected protective enclosure is required, while sensor installation conditions must correspond to its construction and the product instructions.

    Promfactor Baltic FRT11 – modular temperature controller with NTC sensor

    FRT11 is an electronic DIN-rail thermostat designed for automatic control of heating equipment and temperature maintenance systems. Temperature adjustment from −5 °C to +40 °C, adjustable hysteresis, 24–240 V AC/DC supply, one 1 C/O changeover contact up to 16 A, external NTC sensor with 2.5 m cable and LED status indication. A two-DIN-module enclosure, 35 mm DIN mounting and IP20 protection make it a practical solution for temperature control circuits in residential, commercial and industrial installations.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.