Products catalog

  • Three-phase voltage monitoring relay | 3F+N | up to 10 A | asymmetry | phase sequence | DIN | DigiTOP | VP-380V

    Code: VP-380V

    The DigiTOP VP-380V is a three-phase voltage monitoring relay (3F+N) that monitors phase voltages, asymmetry, phase loss and phase sequence.

  • Three-phase voltage monitoring relay | 3F+N | up to 10 A | asymmetry | phase sequence | DIN | DigiTOP | VP-380V

    The DigiTOP VP-380V is a three-phase voltage monitoring relay (3F+N) that monitors phase voltages, asymmetry, phase loss and phase sequence. It is intended for a small three-phase load or for controlling a contactor coil – contact current up to 10 A.

    Key point:
    The biggest dangers for a three-phase motor are a lost phase and a wrong phase sequence. The VP-380V detects them and disconnects the equipment via a contactor before the motor overheats or starts running backwards.
    Contact current
    up to 10 A
    Network
    3F+N
    Monitoring
    asymmetry, phase sequence
    Purpose
    small load / contactor

    How it works

    The relay is connected to a three-phase network with neutral; at least two phases and neutral are needed for normal operation. A microcontroller analyses phase voltages, asymmetry and phase sequence.

    When a fault is detected, the relay disconnects a small load or the contactor coil via its contact, and the contactor disconnects the high-power equipment.

    When the parameters return to normal, the equipment is switched on again. Settings are stored in non-volatile memory.

    Why choose the VP-380V?
    An inexpensive way to protect a three-phase motor, pump or compressor against a lost phase, asymmetry and wrong phase sequence.

    Technical specifications

    Product type Three-phase voltage and phase monitoring relay
    Manufacturer / model DigiTOP / VP-380V
    Network 3F+N, 3×230/400 V AC
    Maximum load current 10 A
    Monitored phase voltage, asymmetry, phase loss, phase sequence
    Supply from the monitored network, at least 2 phases and N required
    Display LED
    Mounting 35 mm DIN rail
    Operating temperature −25…+50 °C
    Degree of protection IP20 (in damp locations only in a sealed enclosure)

    Main functions

    • Phase loss monitoring – the motor is disconnected when one phase is lost.
    • Phase sequence monitoring – prevents starting a motor with swapped phases.
    • Asymmetry monitoring – protects against unequal phase voltages.
    • Voltage display – phase voltage is shown on the display.

    Where is it used?

    • Three-phase motors with contactor
    • Borehole and drainage pumps
    • Compressors, fans
    • Farm and workshop control panels
    • Control panels with phase monitoring

    Use by need

    For the automation installer.
    Simple phase monitoring in the contactor control circuit.
    For a farm or workshop owner.
    The pump and compressor are protected against a lost phase.
    For the electrician.
    A compact solution to upgrade an existing motor panel.

    Practical use

    A borehole pump is controlled by a contactor. When one phase is lost, the VP-380V disconnects the contactor coil and the pump does not burn out running on two phases.

    Pros

    • Monitors phase loss, sequence and asymmetry
    • Compact
    • Suitable for contactor control
    • Settings are retained

    Cons / limitations

    • Contact up to 10 A – high-power loads need a contactor
    • Neutral conductor required
    • Does not protect against lightning surges

    Safety and installation notes

    • Install only after disconnecting the supply and checking that no voltage is present; work must be done by a qualified electrician.
    • Connect high-power loads only via a contactor – the relay contact is rated up to 10 A.
    • Use ferrules for stranded wires and tighten terminals to the torque specified by the manufacturer.
    • Do not swap phase and neutral – otherwise the phase remains connected to the equipment when the relay trips.
    • Install the surge protective device (SPD) before the relay, closer to the supply point.
    • Do not install in damp, vibrating or explosive environments.

    Quick selection guide

    3F+N
    contact up to 10 A
    phase loss
    phase sequence
    asymmetry
    Suitable when you need:
    • to protect a three-phase motor via a contactor
    • to monitor phase sequence
    • to detect a lost phase
    Check before use:
    • contactor coil current does not exceed the relay contact rating
    • whether an N conductor is present
    • motor thermal protection
    Important reminder: the relay does not replace a motor protection circuit breaker and a thermal overload relay.

    FAQ

    Can a motor be connected directly through the relay?
    No – connect high-power loads via a contactor; the relay contact is rated up to 10 A.
    Is a neutral needed?
    Yes – at least two phases and neutral are needed.
    What does it protect against?
    Phase loss, asymmetry, wrong phase sequence and voltage deviations.
    Does it protect against lightning?
    No – an SPD is needed for that.
    Are settings retained?
    Yes, in non-volatile memory.
    Is it suitable for a single-phase network?
    No – choose a single-phase voltage relay for that.

    Three-phase voltage monitoring relay | 3F+N | up to 10 A | asymmetry | phase sequence | DIN | DigiTOP | VP-380V

    Three-phase voltage monitoring relay DigiTOP VP-380V – phase loss, asymmetry and phase sequence monitoring for three-phase motors.

    Published: 2026-11-13 · Data verified against the manufacturer's manual: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.