RTVS8-75L22 – Sentera Controls transformer fan speed controller with Modbus RTU for single-phase AC motors up to 7.5 A. Supplied from a 115 or 230 VAC network, it changes the speed in 5 sinusoidal voltage steps (0-(80)-110-140-170-190-230 VAC at 230 VAC) – automatically according to the connected Sentera sensor or manually via Modbus.
Key idea:
Quiet transformer control integrated into digital automation: with a Sentera IAQ sensor connected, ventilation runs according to temperature, humidity, CO₂, TVOC, CO or NO₂, and the BMS monitors and controls the controller via Modbus RTU. RTVS8-75L22 is intended for more powerful fans or several fans together (up to 7.5 A).What it is for RTVS8-75L22:
This model is intended for high-power fans (up to 7.5 A) – industrial fans in production halls, warehouses, farm buildings or a larger group of fans.Max. motor current
7.5 AControl
Modbus RTU (RS485), auto / manualPower supply
115 or 230 VAC, 50–60 HzProtection
IP54, TK terminalsOperating principle
The supply (L, N, PE), the motor to the regulated output and the motor thermal protection contacts to the TK terminals are connected. The controller has a relay (unregulated) output of 16 A for resistive load and two RJ45 sockets: the main one – for Sentera devices (24 VDC supply and Modbus), and the “gateway” – for a computer with the 3SModbus software, a Sentera internet module or a BMS.
Inside is an autotransformer with several output taps. Each step supplies the motor with a different preset voltage: 0-(80)-110-140-170-190-230 VAC (at 115 VAC: 0-(40)-55-70-85-95-115 VAC). Control is stepped, not stepless – speed changes in fixed increments. The lowest (80 V / 40 V) tap is present but not connected; other voltages for the 5 steps can be selected by changing the internal wiring.
In automatic mode the speed is selected based on data from the Sentera device (IAQ sensor or Modbus RTU potentiometer) connected to the main RJ45 socket; via Modbus you select the control variable (temperature, humidity, CO₂, TVOC, CO, NO₂), the step sequence (from low to high or vice versa), hysteresis of 2–10 % and a switching interval from 5 s to 10 min. In manual mode the speed is set via a Modbus register. Analogue control via DADCM is also possible.
The output voltage is sinusoidal because it is obtained by a transformer rather than by electronically “chopping” the sine wave. Therefore the motor runs quietly, heats up less and does not hum – the transformer speed controller is also suitable for AC motors that audibly hum at low speed with an electronic (triac) controller. Engineer's note: the speed of an AC asynchronous motor is reduced by increasing slip, so less energy is saved than with an EC fan or frequency inverter. The greatest advantage of transformer control is quiet and reliable motor operation at all steps.
Benefits RTVS8-75L22?
The quietness of a transformer controller and the flexibility of Modbus RTU in one device: air-quality-based control without a separate controller, settings and diagnostics via BMS or computer.Technical specifications
Product type Transformer fan speed controller with Modbus RTU Manufacturer / code Sentera Controls / RTVS8-75L22 Series RTVS8 (1.5 / 2.5 / 3.5 / 5 / 7.5 A) Supply voltage 115 or 230 VAC, 50–60 Hz Max. motor current 7.5 A Regulated output 0-(80)-110-140-170-190-230 VAC (230 VAC) / 0-(40)-55-70-85-95-115 VAC (115 VAC), sinusoidal voltage Relay (unregulated) output 16 A for resistive load; controlled manually or automatically via Modbus Communication Modbus RTU (RS485); RJ45 main socket (24 VDC, A, /B, GND) and RJ45 “gateway” socket (A, /B) Modes Automatic (according to the connected Sentera device) and manual (via Modbus) Control variables Temperature, humidity, CO₂, TVOC, CO, NO₂ Hysteresis / switching interval 2–10 % / 5 s – 10 min Analogue control Via DADCM Motor thermal protection TK terminals Indication Communication, alarm, relay and output LEDs Fuse T-10.0 A-H, 5×20 mm Housing Plastic R-ABS, UL94-V0, grey RAL 7035 Protection class IP54 (EN 60529), for indoor use only Operating environment -10…+35 °C, 5–85 % rH non-condensing Weight 7.75 kg net / 8.15 kg gross Packaging dimensions 325×210×155 mm Compliance LVD 2014/35/EU (EN 60529, EN 60730-1), EMC 2014/30/EU (EN 60730-1, EN 61000-6-1, EN 61000-6-3), RoHS 2011/65/EU, WEEE 2012/19/EU Manufacturer documentation
✔ Recommended by Elektrotechnikos sprendimaiOriginal manufacturer documentation – technical data, wiring diagrams and installation instructions.
Main functions
- Modbus RTU (RS485) – integration into the BMS, settings via the 3SModbus software or a Sentera internet module.
- Automatic mode – the speed is selected according to the temperature, humidity, CO₂, TVOC, CO or NO₂ measured by a Sentera IAQ sensor.
- Hysteresis and switching interval – 2–10 % and 5 s – 10 min – stable operation without frequent step switching.
- Relay output 16 A – for a damper, heater or other device, controlled manually or automatically via Modbus.
- TK terminals and alarm LED – motor overheating and other faults are visible immediately.
- 115 / 230 VAC – also suitable for 115 V networks (export projects).
- SenteraWeb – via the Sentera internet module, the controller can be connected to the SenteraWeb cloud – remote control, monitoring and alerts via the internet.
Where is it used?
- Air-quality-based ventilation (CO₂, TVOC) in offices, schools and halls
- Buildings with a BMS / Modbus RTU network
- Production and storage premises
- Livestock buildings (control according to temperature, humidity or NO₂)
- Sites with 115 V mains
On-demand operation
For the automation engineer.
Modbus RTU, clear registers and two RJ45 connectors – fast integration.For the electrician.
TK, relay output and LED diagnostics without additional modules.For the ventilation installer.
With a Sentera IAQ sensor the system works without a separate controller, and the motor runs quietly.Application guide: how it is used in practice
Typical RTVS8-75L22 applications:
Site What is connected Result Installer's note Classroom, office or hall Sentera IAQ (CO₂) sensor → main RJ45 Speed increases as the CO₂ concentration rises Set the control variable and hysteresis via Modbus Building with BMS BMS → RJ45 “gateway” (Modbus RTU) BMS sets the speed and sees the status Manual mode – speed via a Modbus register Commissioning and adjustment Computer → CNVT-USB-RS485-V2 → “gateway” Parameters are set with the 3SModbus software Modbus settings can be reset via the PROG contacts Livestock building Temperature / humidity sensor → main RJ45; motor TK → TK Ventilation based on indoor climate, motor protected Select the switching interval so that the steps do not jump back and forth Damper or heater Device → relay output Switched on manually or automatically via Modbus Relay load – up to 16 A (resistive) How to select the controller current
Rated current of the motor(s) Recommended model up to 1.5 A RTVS8-15L22 (1.5 A) 1.5–2.5 A RTVS8-25L22 (2.5 A) 2.5–3.5 A RTVS8-35L22 (3.5 A) 3.5–5 A RTVS8-50L22 (5 A) 5–7.5 A RTVS8-75L22 (7.5 A) ← this model Rule: controller max. current ≥ motor rated current (see the motor nameplate). When connecting several fans – motors of the same type – add up their rated currents.When to choose another solution: manual control is sufficient – STR-1; control by a 0-10 VDC signal without Modbus – STVS1; automatic restart and alarm output without Modbus – STRA1; stepless electronic control with Modbus – EVS-1; for an EC fan – SDP potentiometers; for a three-phase motor – STR-4.Pros
- Sinusoidal output voltage – quiet motor operation
- Modbus RTU (RS485), two RJ45 connectors
- Automatic mode with Sentera IAQ sensors
- Supply 115 or 230 VAC
- TK terminals and LED diagnostics
- Relay output 16 A
Cons / limitations
- Step control (5 steps), not stepless
- Higher weight than electronic controllers (7.75 kg net)
- A Modbus tool is required for settings (3SModbus, BMS or Sentera module)
- Operating temperature -10…+35 °C, humidity up to 85 % rH
- Single-phase AC motors only; not suitable for EC fans
Safety and installation notes
- Installation and connection must be carried out by a qualified electrician with the power disconnected.
- Always connect the protective earth (PE).
- The rated current of the motor (or the total of several motors) must not exceed 7.5 A; replace the fuse only with one of the same type and rating.
- The controller is intended only for single-phase, voltage-controllable AC motors; it is not suitable for EC fans or three-phase motors.
- Route data (RJ45 / RS485) cables separately from power cables.
- Do not exceed 16 A on the relay output (resistive load).
- For indoor use only (-10…+35 °C, 5–85 % rH).
Quick selection guide
7.5 A115/230 VACModbus RTUTKSinusoidal voltageIP54Suitable when you need:- quiet stepped AC fan control up to 7.5 A via Modbus RTU;
- air-quality-based ventilation with Sentera IAQ sensors;
- integration into the BMS.
Check before use:- the motor rated current and the mains voltage (115 or 230 VAC);
- which Sentera sensor or BMS you will connect and how you will configure Modbus;
- the ambient conditions (-10…+35 °C, up to 85 % rH).
Important reminder: RTVS8-75L22 does not control EC fans or three-phase motors.FAQ
Is a separate controller required?
No, if you use a Sentera IAQ sensor: it is connected directly to the main RJ45 socket, and the controller selects the step itself.Can it be controlled by a 0-10 V signal?
The datasheet specifies analogue control via DADCM; for direct 0-10 VDC control without Modbus, the STVS1 series is suitable.How do I set the parameters?
Via Modbus RTU: 3SModbus software on a computer (e.g. via a CNVT-USB-RS485-V2 adapter), a Sentera internet module or a BMS.Is it suitable for a 115 V network?
Yes, 115 or 230 VAC supply; at 115 VAC the steps are 55-70-85-95-115 VAC.Can several fans be connected?
Yes, provided their total rated current does not exceed 7.5 A.Transformer fan motor speed controller | Modbus RTU | 7.5A | 115-230VAC | surface-mounted | IP54 | Sentera Controls | RTVS8-75L22
Sentera RTVS8-75L22 – transformer fan speed controller with Modbus RTU up to 7.5 A, 115/230 VAC, 5 sinusoidal voltage steps, automatic mode with IAQ sensors, TK protection, relay output, IP54.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review