Products catalog

  • Wi-Fi internet gateway SenteraWeb | Wi-Fi 2.4GHz | 2×Modbus RTU | 24VDC PoM | DIN rail | IP30 | Sentera Controls | DIGWM

    Code: DIGWM
    Price 177.25 € VAT incl.
    ( 146.49 € VAT excl. )
    276.51 € You save 99.26 €
    Offer is valid until 2026-12-31
    Want another price? Suggest yours!
  • Wi-Fi internet gateway SenteraWeb | Wi-Fi 2.4GHz | 2×Modbus RTU | 24VDC PoM | DIN rail | IP30 | Sentera Controls | DIGWM

    DIGWM – a Sentera Controls internet gateway that connects a single Sentera device or their entire Modbus RTU network to the SenteraWeb cloud. The internet connection is via wireless Wi-Fi only, through an existing router; mounting – DIN rail, protection class IP30.

    Key idea:
    The gateway turns local ventilation automation into a remotely maintained system: settings can be changed from the office, data is logged in the cloud, and you learn about a clogged filter or a motor fault from a notification rather than a customer's phone call.
    Internet connection
    Wi-Fi (WLAN 802.11 b/g/n, 2.4 GHz)
    Modbus
    2 Modbus RTU (RS485) channels
    Power supply
    24 VDC PoM, Imax 35 mA
    Installation / protection
    DIN rail, IP30

    Operating principle

    The module is mounted on a DIN rail and receives 24 VDC power over Modbus (PoM, Imax 35 mA) together with data through the RJ45 socket; it has a 24 VDC output for auxiliary devices. The internet connection is via Wi-Fi only (WLAN 802.11 b/g/n, 2.4 GHz).

    On the master Modbus RTU channel the module polls the connected Sentera controllers, sensors and controllers, while on the second (slave) channel it is itself accessible from the main controller or BMS, so SenteraWeb and the existing automation work together. Data is sent using the MQTT protocol, TCP, UDP and HTTP client modes are supported, the real-time clock has a backup battery, and the firmware is updated over the internet.

    Result – via SenteraWeb the setpoints, limits and parameters of connected devices are changed, firmware updates are installed, data is logged, and alerts (e.g. dirty filter, motor fault) arrive without a site visit.

    Benefits DIGWM?
    One module provides remote access to the entire Sentera Modbus system – fewer service visits, faster fault diagnostics and data history for the customer.

    Technical specifications

    Product type Wi-Fi internet gateway SenteraWeb
    Manufacturer / code Sentera Controls / DIGWM
    Power supply 24 VDC via Modbus (PoM), Imax 35 mA
    Output for auxiliary devices 24 VDC
    Internet connection Wi-Fi (WLAN 802.11 b/g/n, 2.4 GHz)
    Modbus 2 Modbus RTU (RS485) channels: for slave devices and for the master controller / BMS
    Connections RJ45 socket (24 VDC PoM + Modbus RTU), 2 Modbus RTU channels (for slave devices and the main controller / BMS)
    Protocols MQTT; TCP, UDP and HTTP client modes
    Cloud SenteraWeb
    Clock Real-time clock with backup battery
    Update Firmware is updated over the internet
    Reset PROG P1: jumper 1–2 ≥5 s – reset of Modbus communication parameters; 3–4 – update mode; switch: short press – factory Modbus registers, 4 s – Wi-Fi disconnection
    Default IP address 192.168.1.123 (after Wi-Fi reset)
    Installation DIN rail
    Housing ABS, UL94-V0, grey RAL 7035
    Protection class IP30
    Operating environment -10…+60 °C, 5–95 % rH non-condensing
    Weight 0.128 kg net
    Package package 96 × 94 × 40 mm
    Compliance EMC 2014/30/EU, RED 2014/53/EU (EN 300 328, ETSI EN 301 489-1/-17), EN 60950-1, EN 62311, WEEE, RoHS, EN IEC 63000

    Manufacturer documentation

    ✔ Recommended by Elektrotechnikos sprendimai

    Original manufacturer documentation – technical data, wiring diagrams and installation instructions.

    Main functions

    • SenteraWeb access – Configuring and monitoring Sentera devices over the internet.
    • Two Modbus RTU channels – SenteraWeb and the BMS / master controller can work with the same system at the same time.
    • Warnings and notifications – e.g. a clogged filter or a motor fault – the message arrives without a site visit.
    • Data logging – history of measurements and statuses in the SenteraWeb database.
    • Remote update – firmware and parameters of connected devices are updated via SenteraWeb.
    • PoM power supply – 24 VDC and Modbus over a single UTP cable; 24 VDC output for auxiliary devices.
    • MQTT, TCP / UDP / HTTP client – standard internet communication protocols.
    • Real-time clock – with a backup battery – correct data timestamps.
    • Low current demand – only 35 mA – barely loads the PoM line.

    Where is it used?

    • Ventilation systems with Sentera speed controllers and sensors that need to be monitored remotely
    • Automation panels – mounting on a DIN rail next to other Sentera DIN modules
    • Commercial premises, schools, offices – filter and fan status notifications
    • Agricultural buildings, greenhouses, warehouses without permanent staff
    • Sites that already have a BMS but also need SenteraWeb access
    • Service contracts – remote diagnostics and settings changes
    • Panels not reached by an Ethernet cable

    On-demand operation

    For heat recovery unit and AHU panel manufacturers.
    The compact DIN module with a 35 mA current demand barely loads the PoM line.
    For the residential building ventilation installer.
    Connects the system to home Wi-Fi without an additional Ethernet cable.
    For remote maintenance service providers.
    Alerts, data history and settings changes via SenteraWeb.

    Practical application

    If the ventilation panel of a private house has no Ethernet cable but 2.4 GHz Wi-Fi is available, then the DIGWM on a DIN rail, drawing only 35 mA from the PoM line, connects Sentera devices to SenteraWeb for remote monitoring and changing settings.

    Application guide: how it is used in practice

    The DIGWM always sits between the Sentera Modbus network and the internet – only the connected equipment changes:

    Site What is connected Result Installer's note
    Office, school – ventilation according to CO₂ Sentera CO₂ sensors and speed controllers → Modbus channel for slave devices Ventilation runs on demand; CO₂ history and settings – SenteraWeb A unique Modbus address for each device
    Building with BMS BMS → second Modbus channel; Sentera devices → main channel BMS and SenteraWeb work together without conflicting over the line Match the BMS channel communication parameters to the BMS
    Duct system with filters Sentera differential pressure transmitter via Modbus A notification is received when the filter becomes clogged Set the warning threshold in SenteraWeb
    Greenhouse, warehouse, farm building Sentera temperature / humidity sensors and controllers The microclimate is monitored remotely, with alarms delivered as notifications The Wi-Fi signal at the installation site must be stable
    Upgrading an existing Sentera system The module is plugged into an existing PoM Modbus line The system gets remote access without replacing devices Check the power reserve of the PoM source

    How to choose an internet gateway

    Installation location / internet connection Recommended model
    Panel (DIN rail); Ethernet or Wi-Fi DIG-M-2 (DIN, Ethernet / Wi-Fi, IP20)
    Panel (DIN rail); Wi-Fi only DIGWM (DIN, Wi-Fi, IP30) ← this model
    On a wall; Ethernet or Wi-Fi SIG-M-2 (wall-mounted, Ethernet / Wi-Fi, IP54)
    On a wall, more demanding environment; Wi-Fi only SIGWM (wall-mounted, Wi-Fi, IP65)
    Rule: first decide on the installation location (panel – DIN models DIG-M-2 / DIGWM, wall – SIG-M-2 / SIGWM), then the internet connection: if an Ethernet cable can be run on site – choose a model with Ethernet (DIG-M-2, SIG-M-2); if only Wi-Fi is available – DIGWM or SIGWM. For damp or dusty environments – wall-mounted models with IP54 / IP65.
    When to choose another solution: for local configuration from a computer – CNVT-USB-RS485-V2 / CNVT-USB-RS485-SET; for PoM power and distribution – PDM-8-MB, MDB-M-6, DMDBM22.

    Pros

    • Remote monitoring and configuration via SenteraWeb
    • 2 Modbus RTU channels – BMS compatible
    • Fault and filter notifications
    • Power over Modbus (PoM) – a single UTP cable
    • Clock with backup battery, updated via the internet
    • IP30 enclosure, mounting – DIN rail

    Cons / limitations

    • Wi-Fi (2.4 GHz) only – for wired Ethernet choose DIG-M-2
    • An internet connection is required on site
    • Designed for Sentera devices and the SenteraWeb platform
    • A 24 VDC PoM power supply is required
    • IP30 – install in a panel or a dry room

    Safety and installation notes

    • Installation and connection are to be carried out by a qualified electrician or automation specialist with the power disconnected.
    • Do not exceed the power of the Power over Modbus (PoM) supply – add up the currents of all devices powered on the line.
    • Use in an environment of -10…+60 °C, 5–95 % rH, non-condensing.
    • Use the PROG jumpers and the reset switch only as instructed – they change the communication settings and may break the Wi-Fi connection.

    Quick selection guide

    SenteraWeb
    Wi-Fi
    2×Modbus RTU
    24 VDC PoM
    IP30
    DIN
    Suitable when you need:
    • to connect Sentera devices to SenteraWeb and monitor them remotely;
    • to receive filter and fault warnings;
    • to integrate SenteraWeb with an existing BMS via the second Modbus channel.
    Check before use:
    • whether the installation site has a stable Wi-Fi (2.4 GHz) signal;
    • whether the PoM power supply has sufficient power reserve;
    • whether all connected devices have unique Modbus addresses.
    Important reminder: The DIGWM is not a controller – it only gives the Sentera Modbus system access to the internet and SenteraWeb.

    FAQ

    Can it be used together with a BMS?
    Yes, the module has a second Modbus RTU channel through which the master controller or BMS accesses it.
    How is the module powered?
    The module is powered with 24 VDC over Modbus (PoM) through the same UTP cable that carries the data, and draws up to 35 mA.
    Can fault notifications be received?
    Yes, via SenteraWeb you receive alerts, for example about a dirty filter or a motor fault.
    Is there an Ethernet connection?
    No, this model connects only via Wi-Fi; for wired connection choose DIG-M-2 or SIG-M-2.
    What should I do after changing the Wi-Fi network?
    Hold the reset switch for 4 s to break the existing Wi-Fi connection, and the module returns to the factory IP address for a new connection.
    Where should it be mounted?
    On a DIN rail in a control panel or a dry room, since the housing is IP30.

    Wi-Fi internet gateway SenteraWeb | Wi-Fi 2.4GHz | 2×Modbus RTU | 24VDC PoM | DIN rail | IP30 | Sentera Controls | DIGWM

    Sentera DIGWM – a Wi-Fi internet gateway that connects Sentera Modbus RTU devices to SenteraWeb: Wi-Fi (WLAN 802.11 b/g/n, 2.4 GHz), 2 Modbus channels, 24 VDC PoM, IP30, DIN rail mounting, remote monitoring and notifications.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals

    privacy policy

    Information