Products catalog

Lamp housings moisture-resistant | hermetic

  • Waterproof batten housing guide: length, number of tubes, power supply and IP

    A waterproof housing is a luminaire without a light source: it already contains the lamp holders, sealing and wiring, and you fit the T8 LED tubes yourself. This lets you choose the brightness and colour, and if a tube fails you replace only the tube. The guide covers quick selection by situation, four selection steps, a matrix of all housings in the group and the most common mistakes.

    Colour meanings: ■ information · ■ benefit, solution · ■ danger, safety.

    What do you need? Quick selection

    Situation Solution
    An old 2×58 W fluorescent fitting hangs in the garage or warehouse and you want LED Twin 150 cm housing: 2× 150 cm with internal wiring (single-end supply) or Bemko 2× 150 cm + two T8 LED tubes 150 cm
    Basement, storeroom, narrow corridor – one tube is enough Bemko 1× 60 cm, Bemko 1× 120 cm or Bemko 1× 150 cm
    Workshop, workbench – more light is needed in the same spot Twin housing: Bemko 2× 120 cm, 2× 120 cm with internal wiring or Bemko 2× 150 cm
    Low or small room: storeroom, stairwell, boiler room Short 60 cm housing: Bemko 1× 60 cm or Bemko 2× 60 cm
    You want to choose the length and number of tubes on one product page Waterproof housing with length options (658 / 1266 / 1566 mm)
    You do not want to assemble tubes – you need a ready-made luminaire Complete waterproof LED luminaires: Moisture-resistant luminaires | waterproof
    Dry, heated room with no moisture or dust IP20 housings have been moved to Accessories for luminaires | lamps – they are not suitable for damp rooms

    The housing lasts a long time – you change the tube as needed

    Once the housing is installed, you can later fit brighter LED tubes or tubes of a different colour without dismantling the installation. It is the cheapest way to convert old fluorescent lighting to LED.

    Step 1: tube length

    T8 tube lengths are standard, and the wattage of an old fluorescent tube simply indicates its length. So “2x58W” in the product name means two 150 cm tubes, not the LED wattage.

    Tube length Old fluorescent tube wattage Typical LED T8 tube wattage Housing length in the group
    60 cm 18 W approx. 9–10 W 658–660 mm
    120 cm 36 W approx. 18 W 1260–1266 mm
    150 cm 58 W approx. 22–24 W 1560–1566 mm

    In practice: measure the old fitting or tube – 60, 120 or 150 cm – and choose a housing of the same length. Check the LED tube wattage on the tube's product page.

    Step 2: one or two tubes

    ■ Single (1× tube)
    Narrow housing (78 × 65 mm) – for basements, storerooms, corridors and rows of shelving. Cheaper and easier to install.
    ■ Twin (2× tubes)
    Twice as much light from one point – for garages, workshops, warehouses and workplaces. Fewer fixing points and less cable.

    Step 3: single-end or double-end supply

    This is the most common reason why a new LED tube does not light up in the housing. A single-end tube receives L and N through one end, a double-end tube receives L through one end and N through the other. The housing wiring and the tube must match.

    A. Single-end supply (L and N at one end) T8 LED tube L N other end – holder only B. Double-end supply (L at one end, N at the other) T8 LED tube L N The housing wiring and the tube type must match. A type A tube in a type B housing (or vice versa) will not light up.

    In this group, the 2× 120 cm and 2× 150 cm housings with internal wiring are wired only for single-end tubes. Check the wiring of other housings on the product page or ask us before buying the tubes.

    Step 4: IP rating, temperature and environment

    All housings in this group are IP65: 6 – dust-tight, 5 – protected against water jets from any direction (IEC 60529). This is suitable for garages, warehouses, basements, boiler rooms, car washes and under canopies.

    • Temperature: For Bemko housings the manufacturer specifies an operating temperature of −10…+35 °C. In an unheated building where it gets colder in winter, choose a luminaire designed for that.
    • Sun: The PS (polystyrene) diffuser gradually yellows under UV – outdoors, install only under a roof.
    • Impacts: Impact resistance of Bemko housings is IK08 (IEC 62262).
    • Dry rooms: IP20 housings have been moved to Accessories for luminaires | lamps – they are not suitable for damp rooms.

    Selection matrix: all housings in the group

    Housing Tubes Dimensions, mm Protection Notes
    Bemko 1× 60 cm 1× T8 LED 60 cm 660 × 78 × 65 IP65, IK08 ABS / PS, operating t° −10…+35 °C
    Bemko 2× 60 cm 2× T8 LED 60 cm 660 × 95 × 78 IP65, IK08 ABS / PS, operating t° −10…+35 °C
    Bemko 1× 120 cm 1× T8 LED 120 cm 1260 × 78 × 65 IP65, IK08 ABS / PS, operating t° −10…+35 °C
    Bemko 2× 120 cm 2× T8 LED 120 cm 1260 × 95 × 78 IP65, IK08 ABS / PS, operating t° −10…+35 °C
    2× 120 cm with internal wiring 2× T8 LED 120 cm 1260 × 115 × 90 IP65 Single-end tubes only; PS diffuser, ABS base
    Bemko 1× 150 cm 1× T8 LED 150 cm 1560 × 78 × 65 IP65, IK08 ABS / PS, operating t° −10…+35 °C
    Bemko 2× 150 cm 2× T8 LED 150 cm 1560 × 95 × 78 IP65, IK08 ABS / PS, operating t° −10…+35 °C
    2× 150 cm with internal wiring 2× T8 LED 150 cm 1560 × 115 × 90 IP65 Single-end tubes only; PS diffuser, ABS base
    Housing with length options T8 LED 60 / 120 / 150 cm 658 / 1266 / 1566 × 110 × 97 IP65 Select the option on the product page

    Tubes are not included with the housings. Data from manufacturer and supplier specifications; if a parameter is not specified, we do not state it.

    Solution levels: from a single tube to a whole site

    1. Upgrade
    Old fitting → IP65 housing of the same length + T8 LED tubes. The same cable and switch.
    2. Garage, workshop
    Several twin 120–150 cm housings in a row, a separate protective device for the lighting circuit, a switch by the door.
    3. Ready-made luminaire
    No need to assemble tubes – waterproof LED luminaires with an integrated light source.
    4. Whole site
    Warehouse, farm, production – lighting plan, motion sensors, group control. We prepare a quotation based on your list of rooms.

    Most common mistakes

    Mistake Consequence How to avoid it
    A double-end tube fitted into a housing wired for single-end supply (or vice versa) The tube does not light up; in some cases – a short circuit inside the tube Check the tube type against the housing product page and the tube marking
    A fluorescent tube fitted into an LED housing It does not light up – the housing has no ballast or starter These housings take T8 LED tubes only
    Cable brought in without a sealed gland or an extra hole drilled IP65 no longer applies, condensation builds up, contacts corrode Use the intended cable entry and a cable of the correct diameter
    Housing installed in an unheated room where it drops below −10 °C in winter The plastic becomes more brittle and the sealing deteriorates Check the operating temperature on the product page; for cold rooms choose a luminaire designed for that
    PS diffuser outdoors in direct sunlight The diffuser yellows and cracks Outdoors, install only under a roof, out of direct sunlight
    IP20 housing in a damp room Moisture and dust reach the terminals – risk of electric shock and failure For damp rooms – only IP65 housings from this group
    Fazė⚡ Safe installation – Fazė's tip
    • Before installing or changing tubes, switch off the circuit breaker and check that no voltage is present.
    • Installation and connection must be carried out by an electrician; in Class I housings the protective conductor (PE) is connected to the dedicated terminal.
    • Protection against electric shock in damp rooms is ensured by a sealed housing, a correctly connected PE and a residual current device (RCD) in the circuit.
    • After closing the diffuser, check that all clips are engaged – only then does IP65 apply.
    ☝ Elsprendimai.eu recommends: order T8 LED tubes of the right length and supply type at the same time – we will match them to the housing so there is no risk of incompatibility. If you need a ready-made solution without assembling tubes, see waterproof LED luminaires or luminaires for basements and damp rooms.

    Frequently asked questions

    Kibirkštis, a young and curious electrician, asks; Fazė, an experienced electrical engineering specialist, answers.

    Kibirkštis
    KibirkštisWhat length of housing do I need to replace an old 2×58 W fitting?
    Fazė
    FazėFor 150 cm tubes the housing length is approx. 1560 mm. The old 58 W meant a 150 cm tube, so the suitable options are 2× 150 cm or Bemko 2× 150 cm.
    Kibirkštis
    KibirkštisHow do I know whether a tube is single-end or double-end?
    Fazė
    FazėCheck the tube marking or packaging: it often says “single-end” / “double-end” or shows a diagram. You will find the housing type on its product page.
    Kibirkštis
    KibirkštisCan fluorescent T8 tubes be used?
    Fazė
    FazėNo. These housings are designed for LED tubes – they have no ballast or starter.
    Kibirkštis
    KibirkštisCan it be installed in an unheated garage in winter?
    Fazė
    FazėYes, if the temperature stays within the housing's operating range. Bemko housings are rated −10…+35 °C, so for very cold rooms choose a luminaire designed for that.
    Kibirkštis
    KibirkštisCan it be installed outdoors?
    Fazė
    FazėYes, under a roof and out of direct sunlight – IP65 protects against dust and water jets, but the PS diffuser gradually yellows under UV.
    Kibirkštis
    KibirkštisWhere have the IP20 housings gone?
    Fazė
    FazėThey are intended for dry rooms only, so they have been moved to Accessories for luminaires | lamps.
    Kibirkštis
    KibirkštisDo you help select housings and tubes for a project?
    Fazė
    FazėYes. Send us the list of rooms, floor area and number of existing fittings – we will select housings and tubes and prepare a quotation. Contact us.

    This guide is intended for orientation when choosing products. UAB „Elektrotechnikos sprendimai“ accepts no liability for decisions made solely on the basis of this guide – final selection and installation must be carried out by a qualified electrician according to site conditions and the manufacturer's instructions. Other guides – in the product selection guide catalogue.

    Sources

    Manufacturer data and standards used in this guide. Checked 2026-11-01.

    • Technical data of the Bemko waterproof housing series
    • Supplier specification – waterproof housings 2× T8 LED 120 / 150 cm with single-end supply
    • IEC 60529 – degrees of protection (IP code)
    • IEC 62262 – degrees of protection against mechanical impacts (IK code)

    Housings and tubes – in one order

    Waterproof housings, T8 LED tubes and ready-made luminaires – all in one place. Send us the list of rooms and number of existing fittings: we will select compatible components and prepare a quotation. The model you need is not in the catalogue? Some products are supplied to order.

    Get a quotation

    Hermetic (moisture-proof) lamp housings – reliable solutions designed to protect luminaires and the bulbs inside them from moisture, dust, dirt, and other environmental effects. Such housings are used both in households – bathrooms, garages, terraces – and in industry, warehouses, production facilities, or outdoors, where lighting equipment operates under challenging conditions.

    They ensure that lighting remains safe, reliable, and long-lasting, even in rain, snow, high humidity, or dusty environments.

    Features

    Moisture protection – special sealing elements (rubber gaskets, clamping covers) prevent water from entering.

    Dust protection – hermetic design protects the lamp from dust, sand, or insects.

    Mechanical protection – housings are made of impact-resistant plastic or metal.

    Versatility – can be mounted on walls, ceilings, outdoors, or indoors.

    Durability – resistant to UV rays and temperature fluctuations.

    Applications

    For household users: in garages, basements, outdoor terraces, or garden houses.

    For engineers: when designing lighting systems requiring moisture protection (e.g., in logistics centers, industrial premises, warehouses).

    For electricians: when installing luminaires on building facades, street lighting, underground garages, or humid industrial spaces.

    For other specialists: construction companies, architects, interior designers – as a solution for both functional and decorative lighting.

    Advantages

    Ensures a high level of protection (usually IP65–IP68).

    Long-lasting and reliable – resistant to environmental effects.

    Wide design selection – from simple technical housings to aesthetic solutions for homes.

    Universal application – suitable for both household and industrial use.

    Disadvantages

    Installation may be more complex due to sealing elements.

    Hermetic lamp housings – an indispensable solution wherever lighting must be safe and durable under harsh conditions. They provide reliable protection against moisture, dust, and mechanical damage, making them relevant for household users, engineers, and electricians alike. It is an investment that guarantees safe and high-quality lighting for many years. 

    Read more
    Waterproof luminaire housing for LED tubes | 2× T8 150 cm | single-ended supply | 2x58W | 230V | 1560x115x90 mm | IP65 | without tubes | SW06258
    Code: SW06258

    Waterproof (IP65) surface-mounted luminaire housing for two 150 cm T8 LED tubes with single-ended supply. Supplied pre-wired, without tubes. Designed for garages, warehouses, basements and technical rooms.

    Price 14.90 € VAT incl.
    ( 12.31 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information