Products catalog

  • Axial wall fan | supply and exhaust airflow | D400 | 180 W | 3830 m³/h | 230 V | 540x540 mm | with flange | metal | black

    Code: 39509

    D400 axial wall fan with 540×540 mm plate and external rotor motor: 3830 m³/h, 130 Pa, 180 W, 1400 rpm. Suitable for supply and exhaust in warehouses, workshops, boiler rooms and farm buildings.

  • Axial wall fan | supply and exhaust airflow | D400 | 180 W | 3830 m³/h | 230 V | 540x540 mm | with flange | metal | black

    D400 axial wall fan with a square 540×540 mm mounting plate (flange) and an external rotor motor. It delivers up to 3830 m³/h of airflow at 130 Pa and can be used for either air supply or exhaust, depending on the mounting direction.

    Key point:
    A simple and reliable solution when heat, moisture or polluted air must be removed quickly from a warehouse, workshop, boiler room or technical room. The fan is mounted directly in the wall or ceiling on its plate, without a complex duct system.
    Airflow
    3830 m³/h
    Power / current
    180 W / 0.82 A
    Speed
    1400 rpm
    Plate
    540×540 mm, opening Ø430 mm

    We will help you set up speed and automatic control

    We will advise how to adjust this fan's speed and how to switch or control it automatically according to room conditions – humidity, temperature or CO₂ concentration. We will select a suitable speed controller, thermostat, humidity or CO₂ sensor and explain how to connect them.

    Contact us: tel. +370 658 01033 or e-mail info@elsprendimai.eu

    In your e-mail, briefly describe the situation: room purpose and size, fan model and what you want to control – speed, humidity, temperature or CO₂.

    Wholesale quantities: special prices for larger orders. State the required quantity in your e-mail and we will send you an individual offer.

    Operating principle

    The fan is fixed to a wall or ceiling through four Ø10 mm holes in the square plate (485 mm hole spacing) over a Ø430 mm opening. The external rotor motor is built directly into the impeller hub, so the design is compact – total depth is only 170 mm.

    The five-blade axial impeller rotates at 1400 rpm and moves air along its axis. Depending on the mounting direction, the fan works as a supply or exhaust unit. Axial fans are intended for low-pressure systems and perform best directly through a wall or with a short duct.

    Why choose the D400 fan?
    High airflow (3830 m³/h) at low electrical power (180 W) – efficient room ventilation and equipment cooling without an expensive ventilation system.

    Technical specifications

    Product type Axial wall fan with mounting plate
    Code 39509
    Size D400
    Airflow 3830 m³/h
    Pressure 130 Pa
    Power consumption 180 W
    Current 0.82 A
    Power supply Single-phase, 230 V AC
    Speed 1400 rpm
    Motor External rotor asynchronous
    Noise level 63 dB(A)
    Airflow direction Supply or exhaust (depending on mounting direction)
    Mounting plate (A) 540 × 540 mm
    Opening diameter (d) Ø430 mm
    Depth (C) 170 mm
    Fixing holes 4 × Ø10 mm, 485 mm spacing (X)
    Material Steel with black polymer coating
    Weight 8.1 kg

    Main functions

    • Supply or exhaust – one product for both modes – just choose the mounting direction.
    • External rotor motor – compact design and smooth impeller rotation.
    • Square plate with flange – quick fixing in a wall, ceiling or to a square duct.
    • Protective guard – prevents accidental contact with the impeller.
    • Polymer coating – resistant to moisture and environmental exposure.

    Where is it used?

    • Warehouses and logistics premises
    • Workshops, garages, car services
    • Boiler rooms and technical rooms
    • Farm buildings, barns, greenhouses
    • Cooling of compressors and condensing units
    • Commercial kitchens (general ventilation)
    • Heat removal from electrical and server rooms

    Use by need

    For farmers.
    Removes moisture and heat from barns, storage buildings or greenhouses at low power.
    For workshop or garage owners.
    Quickly clears dust, fumes and exhaust gases.
    For installers.
    Simple installation through the plate in a wall, without ductwork.

    Practical application

    If heat builds up in a 290 m³ warehouse in summer, a D400 fan installed as exhaust high on the wall removes up to 3830 m³ of air per hour – about 13 air changes per hour. With supply grilles installed lower on the opposite wall, the room is ventilated effectively.

    Pros

    • 3830 m³/h airflow at 180 W
    • Supply or exhaust mode
    • Compact – only 170 mm deep
    • Easy installation with square plate
    • Durable polymer coating
    • Protective guard included

    Cons / limitations

    • No built-in speed controller – external controller required
    • 63 dB(A) noise – not always suitable for living areas
    • Axial fan not suitable for long ducts with high resistance
    • Outdoor installation requires a rain hood or louvres

    Safety and installation notes

    • Disconnect power before installation and maintenance.
    • Protect the supply circuit with a circuit breaker.
    • Fix the plate to a solid base using all 4 bolts.
    • Check that the impeller rotates freely and does not touch anything.
    • Do not remove the guard in accessible locations.
    • When installed outdoors, protect the motor from direct rain.

    Quick selection guide

    D400
    3830 m³/h
    180 W | 230 V
    540×540 mm
    Suitable when you need:
    • to ventilate a warehouse, workshop or farm building
    • to cool compressors or condensing units
    • to install the fan directly in a wall
    Check before use:
    • whether a Ø430 mm opening can be made in the wall
    • that the supply voltage is 230 V
    • that the room has an air inlet
    • that the noise level is acceptable
    Important reminder: the fan has no backdraft damper – when stopped, air may flow back; if this matters, install it with louvres or a backdraft shutter.

    FAQ

    Can it be used for both supply and exhaust?
    Yes, the direction depends on which side the fan is mounted.
    What size opening is needed?
    About Ø430 mm; the plate is fixed with 4 bolts at 485 mm spacing.
    Can the speed be adjusted?
    There is no built-in controller; speed can be controlled with a suitable external controller.
    How much power does it use?
    About 180 W, current 0.82 A.
    How loud is it?
    About 63 dB(A), so it is better suited to technical and utility rooms.
    Can it be connected to a duct?
    Yes, to a short square duct with a matching flange.

    Axial wall fan D400 | 3830 m³/h | 180 W

    D400 axial wall fan with 540×540 mm plate and external rotor motor: 3830 m³/h, 130 Pa, 180 W, 1400 rpm. Suitable for supply and exhaust in warehouses, workshops, boiler rooms and farm buildings.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.