Products catalog

  • Deflector base D600 | galvanised steel | silver

    Code: 28124
    Barcode: 4772318701416

    Galvanised steel roof base D600 with a round spigot. Allows a D600 rotary deflector to be installed with a tight seal when the ventilation duct ends at roof level.

  • Galvanised steel deflector base D600

    The base is a roof plate with a round spigot onto which the rotary deflector is fitted. It is needed when the ventilation duct does not project above the roof or when the deflector needs a firm and sealed base.

    Key point

    The plate covers the opening in the roof, and the spigot forms a tight joint with the D600 deflector. Galvanised steel is coated with a zinc layer that protects the metal from corrosion in normal outdoor conditions. Choose a base and deflector of the same material – mixed metals corrode faster.

    Connection diameter
    D600 mm
    Material
    Galvanised steel
    Type
    Roof base
    Colour
    Silver

    ⚠ For ventilation only

    The deflector is intended for ventilation ducts only – to extract humid and warm air. Do not install it on flues of stoves, fireplaces, sauna heaters or boilers: hot flue gases and acidic condensate will damage it, and there is a risk of fire and carbon monoxide (CO) poisoning.

    How it works

    • The plate is placed over the roof opening and fixed with screws.
    • The joint with the roofing is sealed with sealant or a gasket.
    • A deflector of the same D is fitted onto the spigot.
    operating principle and estimated air extraction | elsprendimai.eu
    ☝ Click the diagram to open an enlarged version.

    Technical specifications

    Product type Deflector base (roof plate with round spigot)
    Connection diameter D600 mm
    Material Galvanised steel
    Colour Silver
    Fixing With screws (screws not included)
    Compatible with D600 rotary deflector
    Manufacturer Elsp Group

    Where it is used

    • Installing a rotary deflector on the roof
    • Ventilation duct outlets through the roof
    • Residential, agricultural and commercial buildings
    • Renovation of existing ventilation outlets

    Installation diagram: common mistakes and the correct way

    Galvanised steel deflector base D600 – installation diagram: wrong and right | elsprendimai.eu
    ☝ Click the diagram to open an enlarged version.
    ⚠ The diagram is for guidance only and may contain inaccuracies. Before installation, check it against the manufacturer's instructions and the roofing requirements.
    Responsibility for installation lies with the qualified specialist performing it. UAB „Elektrotechnikos sprendimai“ is not liable for installation or possible errors.
    ☝ Elsprendimai.eu recommends:

    ✓ Pros

    • Tight joint between the roof and the deflector
    • Firm base – the deflector does not wobble in the wind
    • Same material as the deflector – no galvanic corrosion
    • Suitable for new and renovated roofs

    → Limitations

    • Screws and sealant not included
    • The joint with the roofing must be additionally sealed

    ⚠ Installation and maintenance

    • The base D must match the deflector D.
    • Fix with screws suitable for the roofing; seal with a UV-resistant sealant.
    • Leave a slope at the joint for water to drain – water must not collect at the spigot.
    • Roof work is work at height: use fall protection equipment.

    FAQ

    When is a base needed?

    When the ventilation duct ends at roof level or the deflector needs a firm base.

    Can the base be used with a deflector of another material?

    Technically yes, if the D matches, but we recommend the same material – this avoids galvanic corrosion.

    Are screws included?

    No – choose screws and sealant according to the roofing.

    Is it suitable for all roofing types?

    The plate suits most roofing types; on profiled roofing, seal the joint additionally according to the roofing manufacturer's instructions.

    In short

    Galvanised steel base D600 – sealed and firm installation of a D600 rotary deflector on the roof. Choose together with a deflector of the same material. Unsure about the size or roofing? Send us the duct diameter and roof type – we will help you choose.

    Phone: +370 620 72733
    E-mail: info@elsprendimai.eu

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Duct silencer | for ventilation | air ventilation systems | D250 | 600mm | silver | galvanized steel | 250DUS60
    Code: 04938

    The duct silencer is designed for effective noise reduction in ventilation, heat recovery, and industrial air supply and exhaust systems. This noise attenuator is engineered to absorb turbulent air vortices and aerodynamic noise generated by fans in round air ducts, significantly reducing the overall sound emitted by the system.

    The silencer is intended for use in general ventilation systems with clean air, non-explosive environments, and airflows free of sticky or aggressive particles.

    Integrated connection flanges simplify installation into standard round air ducts.

    To achieve maximum noise reduction efficiency, it is recommended to install the silencer as close to the fan as possible. 

    Price 52.78 € VAT incl.
    ( 43.62 € VAT excl. )
    Flexible aluminum air duct | for ventilation | ventilation systems | D250mm | 3,15m | silver | LAO250U
    Code: 18723

    Flexible aluminum air duct - a reliable solution for various ventilation, air circulation and air extraction systems. Thanks to the 80 micron thick aluminum foil, the duct is durable, resistant to high temperature and maintains its shape even under demanding operating conditions.

    The lightweight, flexible and easy-to-install duct is suitable for connecting fans, heat recovery systems, air extraction ducts, kitchen hoods and other ventilation components. 

    Price 13.61 € VAT incl.
    ( 11.25 € VAT excl. )
  • privacy policy