Code: 91920113Price 0.64 € VAT incl.( 0.53 € VAT excl. )CYKY-L 2×1.5 (2×1.5 mm²) – 450/750 V copper power cable for single-phase 230 V circuits without a PE conductor. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. AB Lietkabelis, price per 1 m.
-
CYKY-L 2×1.5 mm² | Copper power cable | no PE core | 450/750 V | black | 1 m | Lietkabelis
CYKY-L 2×1.5 mm² is a copper power cable made by AB Lietkabelis with 2 solid cores, PVC insulation and a black PVC sheath. It is designed for supplying and distributing electrical power in dry and damp rooms, outdoors and in the ground. Cores: L and N (no PE).
Key point:
This is a two-core cable without a protective PE core – it is intended only for circuits where a PE conductor is not required or is run separately. The 1.5 mm² cross-section suits lighting and control circuits. Price is per 1 m.Cores
2 × 1.5 mm² Cu – L, N (no PE)Rated voltage
450/750 V (U0/U)Outer diameter
7.50 mm – for choosing the cable glandCurrent rating (approx.)
~19.5 A (method C, +30 °C)Fire class (CPR)
Eca (EN 50575)Installation
indoors, outdoors, in groundConstruction and operating principle
Each core is a solid annealed copper wire (class 1 to LST EN 60228) with TI1 type PVC insulation. The insulated cores are twisted together and covered with EPDM filler and a TM1 type PVC sheath, so the cable is round, robust and seals well in cable glands.
Core colours to LST HD 308: brown, blue. There is no PE core, so the cable is not used in circuits that require protective earthing.
Under normal conditions the conductor may reach +70 °C, and +160 °C during a short circuit. The permissible current depends on the installation method: in air, in conduit or in the ground the cable cools differently, so the same 1.5 mm² cross-section has a different current rating on different routes.
Why choose CYKY-L 2×1.5?
One cable type for the whole route – from the board indoors to a load outdoors or in another building, without joints when passing from inside into the ground. The 2×1.5 mm² configuration directly matches its purpose: single-phase 230 V circuits without a PE conductor.Technical specifications
Product type Copper power cable with PVC insulation and PVC sheath Manufacturer AB Lietkabelis (Lithuania) Model / designation CYKY-L 2×1.5 Number of cores and cross-section 2 × 1.5 mm² Core functions L and N (no PE) Core colours (LST HD 308) brown, blue Conductor Solid, annealed copper, class 1 (LST EN 60228) Conductor resistance at +20 °C, max. 12.1 Ω/km (LST EN 60228) Insulation TI1 type PVC (LST EN 50363-3) Filler EPDM Sheath TM1 type PVC (LST EN 50363-4-1), black Rated voltage U0/U 450/750 V Test voltage 2 kV Outer diameter (approx.) 7.50 mm Weight (approx.) 93 kg/km Minimum bending radius > 5 cable diameters (~38 mm) Max. conductor temperature +70 °C; short circuit +160 °C Thermal shock 1 h at +150 °C Installation temperature -5 °C to +40 °C Operating temperature -30 °C to +70 °C Approx. current rating 19.5 A (2 loaded cores); HD 60364-5-52, method C, +30 °C Flame propagation Test to LST EN 60332-1-2 Reaction to fire class (CPR) Eca (LST EN 50575), DoP LK-DoP 02/002/LT Compliance 2011/65/EU (RoHS), 2014/35/EU (LVD), Regulation (EU) No 305/2011 Installation Dry and damp rooms, outdoors, in the ground Sales unit 1 m Diameter and weight are the manufacturer’s approximate values. The current rating is indicative: the final value is recalculated for the installation method, cable grouping and ambient temperature.
Main features
- Solid class 1 copper cores – hold firmly in terminals and are easy to shape in boards.
- TM1 PVC sheath and EPDM filler – protect the cores and allow the cable to be laid in damp rooms, outdoors and in the ground.
- 450/750 V rated voltage – a higher margin than 300/500 V installation cables.
- Colour coding to HD 308 – clear identification of L and N, fewer wiring errors.
- Eca class under CPR – the cable has a declaration of performance required for construction products.
- Sold by the metre – you buy exactly the length the route needs.
Where is it used?
- Supplying Class II (double-insulated) equipment
- Low-voltage DC lines outdoors, e.g. 12/24 V lighting
- Yard, facade and path lighting lines
- Control circuits: sensors, push-buttons, gate and barrier automation
- Cable routes in the ground between buildings, in concrete, conduits and cable trunking
- Damp and wet rooms: basements, boiler rooms, garages, outbuildings
Use by need
For a country-house owner.
A simple way to bring 230 V to yard lighting or double-insulated equipment when no PE core is needed.For a lighting installer.
Solid cores are easy to terminate, and the cable can be laid in the ground up to the luminaires.For an automation installer.
Suits power and control lines between the board and outdoor drives or sensors.Practical application
If yard lighting located 30 m away needs a 230 V supply and the expected current is about 6 A, CYKY-L 2×1.5 can be laid in a trench directly in the ground. Approximate voltage drop: 2 × 6 A × 30 m × 12.1 Ω/km ≈ 4.4 V, i.e. about 1.9 % of 230 V (calculated with conductor resistance at +20 °C). The final cross-section and protective device are selected according to the design and installation conditions.Pros
- Suitable indoors, outdoors and in the ground – one cable for the whole route
- 450/750 V rated voltage
- Solid copper cores – reliable contact in terminals
- Made in Lithuania (AB Lietkabelis), declared Eca class
- Compact: ~7.50 mm diameter for a 2×1.5 mm² cable
- Sold by the metre
Cons / limitations
- No PE core – not suitable for circuits that require protective earthing; choose CYKY-L 3G instead.
- Solid cores are not suitable for moving equipment or frequent bending – use a flexible cable (e.g. H07RN-F) for that.
- PVC sheath: do not install below -5 °C.
- Eca class is not suitable where the design requires a higher CPR class or a halogen-free cable.
- The manufacturer does not declare UV resistance – use conduit or trunking for long-term direct sun exposure.
Safety and installation notes
- Before installation, isolate the circuit and verify that it is dead.
- Bending radius – at least 5 cable diameters (about 38 mm).
- Do not install below -5 °C – cold PVC may crack.
- When laying in the ground, follow installation rules: proper depth, sand bedding, warning tape, mechanical protection under roads and driveways.
- Select the protective device according to the cable’s permissible current under the actual installation conditions.
- Work must be carried out by a qualified electrician; measure insulation resistance after installation.
Quick selection guide
2×1.5 mm²450/750 VL and N (no PE)Ø ~7.50 mmEca (CPR)Suitable when you need:- Single-phase 230 V circuits without a PE conductor
- Yard, facade and path lighting lines
- To lay the cable in the ground or in a damp environment
Check before use:- Permissible current and protective device for the installation method
- Voltage drop on long runs
- Whether the design requires a higher CPR class
- Cable gland and seal size for the ~7.50 mm diameter
Important reminder: The cable does not replace calculation – cross-section, protection and installation method are confirmed by the electrical design or a qualified electrician.FAQ
What does the designation 2×1.5 mean?
2 cores of 1.5 mm², without a green/yellow PE core.Can CYKY-L 2×1.5 be laid in the ground?
Yes, the manufacturer states that the cable may be laid in the ground; in a trench follow installation rules for depth, warning tape and mechanical protection.What current can a 2×1.5 mm² cable carry?
Approximately 19.5 A (2 loaded cores) to HD 60364-5-52 (method C, +30 °C); in the ground, in groups or at higher ambient temperature the value is recalculated.How does CYKY-L differ from NYM-J?
NYM-J (300/500 V) is intended for installation inside buildings, while CYKY-L is a 450/750 V cable that can be laid both outdoors and in the ground.What are the cable diameter and weight?
According to the manufacturer – about 7.50 mm and 93 kg/km.At what temperature can it be installed?
Install from -5 °C to +40 °C; operate from -30 °C to +70 °C.CYKY-L 2×1.5 mm² | Copper power cable | no PE core | 450/750 V | black | 1 m | Lietkabelis
CYKY-L 2×1.5 is an AB Lietkabelis copper power cable, 2×1.5 mm², 450/750 V, with solid cores and a black PVC sheath, intended for single-phase 230 V circuits without a PE conductor. Suitable for laying indoors, outdoors and in the ground; Eca class, sold by the metre.
Published: 2026-11-13 · Data verified against the manufacturer’s datasheet: 2026-11-13
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerSingle-core wires are also called monolithic wires,
while multi-core wires are flexible wires.Wires usually have a single conductor covered with an insulating layer.
Cables have several insulated wires, covered with a common sheath.
Conductor properties of wires:
The resistance of copper conductors is lower (0.017Ω) than that of aluminum (0.028Ω),
but copper has better conductivity.
Copper has better electrical and thermal conductivity than aluminum.
Copper wires are more flexible, more resistant to corrosion, and more durable.
Aluminum wires quickly oxidize upon contact with air, forming a film that weakens the contact.
Copper wires carry higher currents than aluminum wires.
Copper conductors are denser than aluminum. Therefore, copper wire is heavier.The cross-sectional area of wires is chosen according to the power of specific equipment,
for example: for a 1kW load, a 1.57 mm² cross-sectional area of the conductor is required.
For aluminum wires: 5A per 1mm², and for copper wires: 8A per 1mm².The electrical supply cable is the main cable through which electricity is supplied from the ESO (Electricity Distribution Operator) meter cabinet to the internal electrical system of the consumer's building. This cable is a crucial link between the electrical network and the building's installation.
Key Features:
Connection to the ESO network – The supply cable connects the building's electrical system to the ESO distribution network. It is the first element of the electrical installation through which electricity enters the building.
Current capacity – The supply cable must be suited to transmit the required current strength according to the consumer's electrical needs (e.g., 25A, 32A, or more).
Environmental resistance – The cable is often installed outdoors or underground, so it must be resistant to mechanical impacts, UV rays, and moisture.
Number of conductors and cross-section – The most commonly used supply cables are 4 or 5 conductors (depending on grounding requirements), with conductors of 16 mm², 25 mm², or more, depending on the expected load.
Example: CYKY 4x16 or CYKY 5x16 – these are popular supply cables used for 3-phase power supply at 230/400V. They have four or five copper conductors designed for higher currents.
The supply cable is a vital link in the electricity supply, so it is important to ensure that it is correctly selected according to the consumer's electrical load and the environmental conditions in which it will be installed.We recommend choosing the CYKY supply cable. For single-phase supply, we recommend a 3-conductor cable (CYKY 3×4 mm², 3×6 mm²), and for three-phase supply, a 5-conductor cable (CYKY 5×4 mm², 5×6 mm²).
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Cable Cutting Scissors | 240mm² | TLK10-250 | 4606056165289Code: TLK10-250Professional cable cutting scissors designed for reliable cutting of copper and aluminum cables with a cross-section of up to 240 mm². These scissors are an essential tool for electrical installations, cable laying works, and for use in the industrial and energy sectors. The tool operates with a two-handed mechanism, ensuring greater safety and cutting precision. The high-quality construction allows operation under various environmental conditions.
Price 48.67 € VAT incl.( 40.23 € VAT excl. )Holder | fastening strap | 22 mm | black | UP-22 | 5901350805718Code: UP-22Holder – a fastening tie designed for securing and organizing cables, wires, and various components. This compact yet strong tie ensures reliable fixation, aesthetics, and safety in electrical installations as well as in household or industrial systems. Due to its simple installation and universal size, this holder is indispensable for both professionals and everyday users.
Price 0.09 € VAT incl.( 0.07 € VAT excl. )Cable sheath and wire stripper 0.2–4.0 mm² | ErgoStrip KNIPEXCode: 169501SBKNIPEX high-quality, ergonomically designed wire and cable stripping tool for fast, precise, and safe work. This stripping knife is highly favored by professional electricians for its versatility, durability, and practical design. Suitable for removing insulation from both signal and power wires, as well as for installation, data, and coaxial cables.
Perfectly suited for use on construction sites and in domestic installations, especially where wires need to be quickly and accurately prepared for connection in confined spaces.
Price 48.40 € VAT incl.( 40.00 € VAT excl. )