Products catalog

  • Sound-insulated mixed-flow duct fan | D100 | 250 m³/h | 50 W | 230 V | 2 speeds | 690×233×236 mm | IPX4 | black | ESLP23485

    Code: ESLP23485

    Sound-insulated mixed-flow duct fan ESLP23485: Ø100 mm, 2 speeds, 250 / 180 m³/h, 190 / 110 Pa, 25 / 19 dB(A), 50 W, 230 V, IPX4. Mounts in the duct in any position.

  • Sound-insulated mixed-flow duct fan | D100 | 250 m³/h | 50 W | 230 V | 2 speeds | 690×233×236 mm | IPX4 | black | ESLP23485

    Mixed-flow duct fan for Ø100 mm ducts, built into a sound-absorbing housing. Two speeds: up to 250 / 180 m³/h and up to 190 / 110 Pa, with a supplier-stated noise level of 25 / 19 dB(A).

    Key point:
    The mixed-flow impeller develops more pressure than an axial fan, while the sound insulation dampens impeller and air noise. This allows the fan to be installed close to bedrooms, offices or meeting rooms where ventilation should be barely audible.
    Air flow
    250 / 180 m³/h
    Pressure
    190 / 110 Pa
    Noise
    25 / 19 dB(A)
    Power / voltage
    50 W / 230 V

    How it works

    The fan is inserted directly into the Ø100 mm duct run – air moves in a straight line. It can be mounted in any position on a bracket; supply is 230 V AC, 50 Hz.

    The angled blade geometry accelerates air both axially and radially, so the fan holds higher pressure in longer runs with grilles or filters. The polypropylene housing with sound-absorbing lining reduces noise reaching the rooms.

    Speed is selected by an external switch or relay contact according to the wiring diagram: low for quiet everyday ventilation, high for boost mode.

    Why choose ESLP23485?
    Quiet duct ventilation with two operating modes and no separate speed controller: up to 250 m³/h and only 19 dB(A) at low speed.

    Technical specifications

    Product type Sound-insulated mixed-flow duct fan
    Product code ESLP23485
    Supply 230 V AC, 50 Hz
    Power 50 W
    Speeds 2 (high / low)
    Air flow 250 / 180 m³/h
    Pressure 190 / 110 Pa
    Noise (supplier data) 25 / 19 dB(A)
    Duct diameter Ø100 mm
    Dimensions (L × W × H) 690×233×236 mm
    Motor single-phase
    Housing polypropylene (PP) with sound-absorbing lining, black
    Protection rating IPX4
    Mounting any position, bracket
    Country of origin Turkey

    Main functions

    • Two speeds – quiet everyday and boost mode without an extra controller.
    • Mixed-flow impeller – up to 190 Pa, suitable for longer runs.
    • Sound-insulated housing – lower noise in living spaces.
    • Easy servicing – the motor unit is removed without taking the housing out of the run.
    • IPX4 – protected against water splashes.
    • Any mounting position – horizontal or vertical in the duct.

    How the models in this series differ

    • D100 · 250/180 m³/h – 190/110 Pa · 25/19 dB(A) · 690×233×236 mm – this model
    • D125 · 355/240 m³/h – 190/110 Pa · 23/17 dB(A) · 690×233×236 mm
    • D150 · 570/415 m³/h – 305/225 Pa · 27/22 dB(A) · 694×253×254 mm
    • D160 · 570/415 m³/h – 305/225 Pa · 26/22 dB(A) · 694×253×254 mm

    Where is it used?

    • Bedrooms and children’s rooms
    • Offices and meeting rooms
    • Supply or exhaust systems in flats and houses
    • Bathroom and WC extraction via duct
    • Hotel rooms
    • Medical consulting rooms
    • Classrooms

    Use by need

    For the designer.
    Flow, pressure and noise known for both speeds – easy to size for a Ø100 mm system.
    For the installer.
    Inserted directly in the duct in any position; the motor is serviced without removing the housing.
    For the homeowner.
    Quiet continuous ventilation in the bedroom and boost mode when needed.

    Practical use

    If several rooms need quiet ventilation through a Ø100 mm duct, the fan runs daily at low speed (180 m³/h, 19 dB(A)) and switches to high speed (250 m³/h) when bathing, cooking or when more people are present. The stated flows are without resistance – in a long run with grilles they are lower, so allow a capacity margin.

    Pros

    • Up to 250 m³/h, 2 speeds
    • Supplier-stated noise 25 / 19 dB(A)
    • Up to 190 Pa
    • Removable motor unit
    • IPX4, lightweight PP housing
    • Mounts in any position

    Cons / limitations

    • Flow drops as system resistance increases
    • The supplier does not state air temperature limits – not for hot air or process vapours
    • Not certified for smoke extraction
    • Long 690×233×236 mm housing – needs space in the run

    Safety and installation notes

    • Disconnect the supply and verify absence of voltage before installation and maintenance.
    • Provide overload and short-circuit protection in the supply circuit; protect bathroom circuits with a 30 mA residual current device (RCD).
    • IPX4 means splash protection: in damp rooms follow the HD 60364-7-701 zone requirements.
    • Fix the fan to a solid base with the bracket and connect the ducts airtight.
    • Inlet and outlet openings must not be blocked.
    • Connection must be carried out by a qualified electrician.

    Quick selection guide

    Ø100 mm
    250 / 180 m³/h
    190 / 110 Pa
    25 / 19 dB(A)
    50 W / 230 V
    IPX4
    Suitable when you need:
    • Quiet ventilation of living or working spaces
    • Supply or exhaust systems with Ø100 mm ducts
    • Two operating modes without a separate controller
    Check before use:
    • Whether the duct diameter is Ø100 mm
    • Whether the 690×233×236 mm housing fits in the run
    • Whether capacity is sufficient after duct resistance
    • How the speeds will be switched (switch or relay)
    Important reminder: The fan does not recover heat – it does not replace a heat recovery unit and works best when its capacity and pressure match the system resistance.

    FAQ

    How are the speeds switched?
    With an external two-position switch or relay contact; a timer, humidity or CO₂ sensor can control it.
    Can it be mounted vertically?
    Yes, the fan can operate in any position.
    Which duct does ESLP23485 fit?
    A Ø100 mm duct.
    Is it suitable for bathroom extraction?
    Yes, the housing is IPX4; protect the circuit with a 30 mA RCD.
    Do I need to remove the fan to service the motor?
    No, the motor unit is removed without dismantling the housing.
    Is it suitable for smoke extraction?
    No, the fan is not certified for that.

    Sound-insulated mixed-flow duct fan | D100 | 250 m³/h | 50 W | 230 V | 2 speeds | 690×233×236 mm | IPX4 | black | ESLP23485

    ESLP23485 is a sound-insulated mixed-flow duct fan for Ø100 mm: 2 speeds, 250 / 180 m³/h, 190 / 110 Pa, 25 / 19 dB(A), 50 W, 230 V, IPX4. For quiet ventilation of bedrooms, offices and meeting rooms.

    Published: 2026-11-13 · Data verified against the supplier specification: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Rotary deflector D100 | ball bearings | 300×100 mm | galvanised steel | silver
    Code: 19427

    Galvanised steel rotary deflector (wind turbine) D100 with ball bearings. Fits onto a D100 ventilation duct, extracts air without electricity and protects the duct from rain and snow.

    Price 78.89 € VAT incl.
    ( 65.20 € VAT excl. )
    Rotary deflector D160 | ball bearings | ABS plastic | blue
    Code: 04512

    ABS plastic rotary deflector D160 with ball bearings, blue. Fits onto a Ø160 mm pipe or ventilation outlet and extracts air without electricity.

    Price 95.59 € VAT incl.
    ( 79.00 € VAT excl. )
    Digital duct temperature and humidity sensor with LCD | 0–10 V DC / 4–20 mA
    Code: SKU#165278098976225941

    Digital duct sensor that measures air temperature and relative humidity in a duct, shows them on an LCD and sends them to a controller as a 0–10 V DC / 4–20 mA signal.

    Price 168.43 € VAT incl.
    ( 139.20 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information