Edge protection profile for enclosures | for 1–2 mm sheet metal | black | 1 m | ESLL
Code: SKU#158439739735445281Black edge protection for cut-outs and edges in 1–2 mm sheet metal of enclosures and metal housings. Pushed onto the edge, it protects wire and cable insulation from being cut. Price per 1 m, minimum quantity 10 m.
-
Edge protection profile for enclosures | for 1–2 mm sheet metal | black | 1 m | ESLL
This is a black edge protection profile for 1–2 mm sheet metal – the thickness most enclosures, distribution boxes and control cabinets are made of. The profile is pushed onto the edge of the cut-out and covers the sharp edge. Cables passing through the opening rest on the profile, not on the metal.
Key point:
Openings in an enclosure are most often cut on site – when replacing equipment or adding a new cable. In that case a few metres of profile are enough, not a whole roll. This product can be bought from 10 m, and the 1–2 mm thickness range lets you check in advance whether it fits your sheet.Sheet thickness
1–2 mmColour
BlackSales unit
1 mMin. quantity
10 mHow it works
Check that the sheet thickness is 1–2 mm and cut the profile to the perimeter of the cut-out.
The profile is pushed onto the cleaned edge and holds on it.
The sharp edge is covered – cables, wires and hands do not touch the metal.
What does this edge protection give you?
The stated 1–2 mm sheet thickness matches most enclosures, so selection is simple. The low minimum quantity (10 m) suits repairs and single sites, and the black colour does not stand out in dark enclosures or on galvanised sheet.Technical specifications
Product type Edge protection profile Code ESLL Purpose Protection of sheet-metal cut-outs and edges in enclosures and housings Suitable sheet thickness 1–2 mm Colour Black Sales unit 1 m Minimum quantity 10 m Main functions
- Fits 1–2 mm sheet – most enclosure and box housings
- Covers the sharp edge – cable insulation is not cut
- Fitted without tools – no glue or rivets needed
- Cut to length – suits round and rectangular cut-outs
- Sold from 10 m – no need to buy a large quantity for one site
Where is it used?
- New cable entry openings in existing enclosures
- Metal distribution and terminal boxes
- Door cut-outs for devices in control cabinets
- Cut-outs in cable trays and trunking
- Sheet-metal edges of equipment housings and frames
- Fan and grille cut-outs in housings
- Reconstruction and upgrading of enclosures
Use by need
For electricians modifying an enclosure.
After adding a cable and cutting an opening, the edge can be finished the same day – a few metres are enough.For automation panel builders.
The clear thickness range (1–2 mm) allows one profile to be standardised for most housings.For facility managers.
If an inspection finds cables rubbing against a sheet edge, the defect can be fixed at low cost.Practical application
If you have drilled a round hole for a new cable in an existing enclosure made of 1.5 mm sheet, remove the swarf and burrs, cut the profile to the perimeter of the hole and push it on – the cable insulation will no longer rub against the sharp edge.Pros
- Clear suitability range – 1–2 mm sheet
- Low minimum quantity – 10 m
- Fitting without tools or glue
- Black colour suits dark and galvanised housings
- Protects both cables and the installer's hands
Cons / limitations
- Not suitable for sheet thinner than 1 mm or thicker than 2 mm
- Does not seal the opening – against moisture and dust use a gland (e.g. VET, MET) or a cable entry plate (e.g. HTC-50)
- Does not secure the cable against pull-out – fix the cable inside the enclosure
- For white enclosures the white edge protection EM-1010-04-01 (min. 100 m) may suit better
Safety and installation notes
- Make cut-outs in the enclosure only with the voltage disconnected and verified absent
- Remove swarf after drilling – it can cause a short circuit
- Deburr the edge so that the profile is not pierced from inside
- Fit the profile along the whole perimeter; place the joint where cable load is lowest
- Measure the sheet thickness with a caliper before ordering
Quick selection guide
Sheet: 1–2 mmColour: blackUnit: 1 mMin. quantity: 10 mSuitable when you need:- to protect cables in cut-outs in 1–2 mm sheet
- a small quantity of profile for a repair or a single site
- dark-coloured edge protection
Check before use:- whether the sheet thickness is 1–2 mm
- whether the cut-out edge is free of burrs and swarf
- whether the opening needs additional sealing
Important reminder: Edge protection only protects against a sharp edge. It does not seal the opening, does not replace a cable gland or cable entry plate and is not a fire barrier.FAQ
What sheet thickness does it fit?
This edge protection is intended for 1–2 mm metal.What is the minimum quantity?
The minimum quantity is 10 m; the price is per 1 m.Is it suitable for round holes?
Yes, the profile is cut to the perimeter of the hole and pushed on around the edge.Is glue needed?
No, the profile is pushed onto a clean edge without glue.Does the profile protect against moisture?
No, to seal the opening use a cable gland or a membrane cable entry plate.Are other colours available?
The range includes the white edge protection EM-1010-04-01, sold from 100 m.Black edge protection for 1–2 mm sheet
Black edge protection for cut-outs in 1–2 mm sheet metal of enclosures and housings protects cable insulation from sharp edges. Price per 1 m, sold from 10 m.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products