Products catalog

  • Fan motor switch-off timer | 2-10 min | 1.5A | VTR-1-V2

    Code: VTR-1-V2

    Fan motor shutdown timer designed for controlling an exhaust fan in a bathroom, toilet, utility room, or other ventilated premises. This timer allows the fan to operate not only when the lighting is switched on, but also for a certain period after the light has been switched off.

    When the lighting is switched on, the exhaust fan is activated simultaneously. After the light is switched off, the fan continues operating for a preset period of time – from 2 to 10 minutes – ensuring more effective removal of moisture, odors, and stagnant air from the room. 

  • Technical Specifications

    Product type: fan motor switch-off timer
    Purpose: delayed operation of an exhaust fan after the lighting is switched off
    Supply voltage: 230 VAC ±10%
    Frequency: 50–60 Hz
    Fan output: 230 VAC ±10%
    Maximum load current: 1.5 A
    Minimum load current: 0.04 A
    Time adjustment range: 2–10 min.
    Protection class: IP20
    Operating temperature: -10 °C to +40 °C
    Relative humidity: 5–85% RH
    Connection: via standard terminals
    Installation: compact, easily integrated into electrical installations
    Application area: indoor premises

    Functions

    Fan activation together with lighting – when the light is switched on in a bathroom, toilet, or other room, the timer activates the exhaust fan
    Automatic switch-off delay – when the lighting is switched off, the fan continues running for the set time and then stops automatically
    Adjustable operating time – the delay time can be adjusted from 2 to 10 minutes according to room size and ventilation requirements
    Improved moisture and odor removal – additional fan operating time helps remove steam, moisture, and unpleasant odors more effectively
    Simple terminal connection – wires are connected to standard terminals, making installation clear and convenient
    230V AC fan control – the timer is designed for standard 230V AC exhaust fans
    Supports loads up to 1.5 A – suitable for low and medium-power domestic exhaust fans
    Automatic ventilation comfort – the user does not need to switch the fan on or off separately, as operation is linked to lighting
    Indoor ventilation automation – suitable for bathrooms, toilets, utility rooms, small sanitary facilities, and commercial indoor spaces

    Applications

    For homeowners: This timer is useful if you want your bathroom or toilet fan to operate automatically without a separate switch. It helps reduce moisture buildup, improves air quality, and increases everyday comfort.

    For electricians: A simple solution for standard residential ventilation systems. Easy terminal wiring allows quick integration into lighting and fan control circuits.

    For engineers or designers: Suitable for designing simple automatic ventilation systems in residential, administrative, or utility premises. The adjustable 2–10 minute delay allows adaptation to room purpose and ventilation requirements.

    For building maintenance specialists: Useful when modernizing older premises where the fan should operate automatically together with lighting. It is an economical way to improve ventilation without complex automation systems.

    For commercial premises: Can be used for ventilation control in offices, small sanitary facilities, changing rooms, utility rooms, and other indoor spaces.

    Advantages

    Automatically controls the exhaust fan based on lighting operation
    Adjustable delay time from 2 to 10 minutes
    Helps remove moisture and odors more effectively
    The fan continues operating after the light is switched off

    Disadvantages

    IP20 protection class is not suitable for direct exposure to moisture or outdoor areas without additional protection
    Not suitable for powerful fans with a current exceeding 1.5 A

    FAQ
    Does this timer switch on the fan together with the light?

    Yes. The timer is designed to switch on the fan together with the lighting. When you turn on the light in a bathroom or toilet, the exhaust fan also starts operating.

    What happens when the lighting is switched off?

    When the lighting is switched off, the fan continues operating for the set time – from 2 to 10 minutes. After this period, the fan switches off automatically.

    Can the fan operating time be adjusted?

    Yes. The fan switch-off delay can be adjusted from 2 to 10 minutes.

    Where can this timer be used?

    It is most commonly used in bathrooms, toilets, utility rooms, small commercial spaces, and other locations where automatic exhaust fan control is required.

    Is this timer suitable for outdoor use?

    No. The device has an IP20 protection class and is intended only for indoor use or installation inside an additionally protected electrical enclosure. 

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.