Products catalog

  • Industrial Dehumidifier | Moisture Collector | 850W | 230V | 60L/24h | 850m³/h | 400x370x700mm | White

    Code: ES-DC-601E

    Mobile industrial dehumidifier is designed to reduce excess humidity in warehouses, production areas, workshops, basements, laboratories and other larger indoor spaces. The maximum stated dehumidification capacity is 60 litres per dayat an ambient temperature of 30 °C and a relative humidity of 80%.

    The unit is microprocessor-controlled and features a digital humidity display, an adjustable target humidity level, automatic defrosting, a 10-litre water tank and a connection for continuous condensate drainage.

    The high airflow of up to 850 m³/h helps circulate air in larger rooms, while the castors allow the dehumidifier to be moved conveniently between work areas. 

  • Industrial dehumidifier – up to 60 l/day, 850 m³/h, 10 l tank, 850 W, 230 V, for 60–120 m² rooms

    Mobile industrial dehumidifier is designed to reduce excess humidity in warehouses, production areas, workshops, basements, laboratories and other larger indoor spaces. The maximum stated dehumidification capacity is 60 litres per dayat an ambient temperature of 30 °C and a relative humidity of 80%.

    The unit is microprocessor-controlled and features a digital humidity display, an adjustable target humidity level, automatic defrosting, a 10-litre water tank and a connection for continuous condensate drainage.

    The high airflow of up to 850 m³/h helps circulate air in larger rooms, while the castors allow the dehumidifier to be moved conveniently between work areas.

    Important information about the 60 l/day capacity:
    The maximum dehumidification capacity is specified at 30 °C and 80% relative humidity. At lower temperatures, lower humidity levels or with weaker air circulation, the actual amount of water collected will be lower.
    Important information about the recommended area:
    The stated 60–120 m² coverage area is calculated for a room with a ceiling height of approximately 3 m. The suitable area depends on the initial humidity, temperature, room airtightness, moisture sources, air exchange and the desired result.
    Important information about protection functions:
    The general information supplied mentions various protection functions and fault indications, but not all of them are clearly associated with this 230 V single-phase model. Before publishing specific protection functions, they should be verified against the model's instruction manual.
    Dehumidification capacity
    Up to 60 l/day
    Airflow
    850 m³/h
    Recommended area
    60–120 m²
    Maximum input power
    850 W
    Water tank
    10 l
    Operating temperature
    +5…+38 °C
    Power supply
    230 V AC, 50 Hz
    Weight
    35 kg

    Operating principle

    The dehumidifier uses a fan to draw humid room air through the front air inlet and pre-filter. The air is directed across a cold heat exchanger, where moisture condenses into water.

    The resulting condensate can be collected in the integrated 10-litre tank or continuously discharged through a hose connected to the Ø14 mm drain connection. The dehumidified air is reheated and returned to the room through the side air outlet.

    As this process repeats, the relative humidity decreases, helping protect rooms, stored materials and equipment against condensation, mould and other problems caused by excess moisture.

    Air direction:
    Humid air is drawn in through the front air inlet, while dehumidified air is discharged through the side air outlet. Sufficient free space must be left around both openings for air circulation.

    Automatic humidity control

    The integrated temperature and humidity sensor monitors room conditions, while the microprocessor controller regulates dehumidifier operation according to the selected target humidity level.

    The liquid-crystal display shows the current relative humidity. The supplied information specifies a humidity display range of 30–90% RH .

    The user can select the desired humidity level, and the dehumidifier switches on or off automatically to maintain the set conditions. The control board retains the settings in the event of a power failure.

    Main control functions:
    • display of the current relative humidity;
    • setting of the desired humidity level;
    • automatic operating control;
    • retention of settings after a power failure;
    • sensor fault indication;
    • full water tank warning and automatic shut-off.

    Automatic defrosting

    At lower ambient temperatures, frost or ice may form on the cold heat exchanger. The microprocessor controller monitors operating conditions and activates the automatic defrost mode when required.

    The defrost function helps protect the heat exchanger and maintain more stable dehumidifier operation at lower temperatures. The stated operating range of the unit is from +5 to +38 °C.

    Operation at low temperatures:
    Automatic defrosting allows the unit to be used in cooler rooms, but at temperatures close to +5 °C the dehumidification capacity will be significantly lower than at 30 °C.

    Two condensate drainage methods

    Collection in the water tank

    • integrated tank capacity – 10 l;
    • no permanent drain pipe is required;
    • suitable for temporary or mobile use;
    • a warning is activated when the tank is full;
    • the dehumidifier stops automatically to prevent water from overflowing.

    Continuous drainage

    • uses a Ø14 mm drain connection;
    • condensate is discharged through the connected hose;
    • the water tank does not need to be emptied regularly;
    • suitable for long-term and continuous operation;
    • the hose must run downwards without kinks or blockages.
    Drainage note:
    If condensate is removed through a gravity-drain hose, its outlet point must be below the dehumidifier's drain connection. The hose must not form loops in which water could collect.

    High airflow of 850 m³/h

    The centrifugal fan generates an airflow of up to 850 m³/h . The high air volume helps circulate humid air through the dehumidifier's heat exchanger more quickly and distribute the dehumidified air more evenly throughout the room.

    The supplied information states that the fan design is intended to reduce air resistance and noise while ensuring a long service life.

    For best results, the unit should be positioned in an open area without obstructing the front air inlet or side outlet.

    Compressor and heat exchanger

    The moisture-condensation system consists of a compressor, heat exchanger, fan and refrigerant circuit. The supplied information specifies a low-noise reciprocating compressor designed for stable and reliable operation.

    A compact heat exchanger with an internally threaded copper tube and aluminium fins is used. This design is intended to increase the heat-transfer surface and condense moisture from the air more efficiently.

    The refrigeration system uses R410A refrigerant. The refrigerant circuit may only be inspected, repaired or recharged by a suitably qualified specialist.

    Refrigeration system safety:
    Do not dismantle the compressor or refrigerant circuit. If the system is damaged, refrigerant may leak, and incorrect repairs may damage the unit or create a hazard.

    Durable metal housing

    The housing is made of reinforced sheet metal. Its surface has a spray-applied anti-corrosion coating designed to protect the metal against oxidation and the effects of everyday use.

    The robust cabinet-style construction is suitable for commercial and industrial use. Castors fitted underneath allow the 35 kg dehumidifier to be moved, while castor locks help keep it stable in the selected position.

    Transport note:
    After the compressor dehumidifier has been transported or laid on its side, place it upright and wait for the period specified in the instructions before switching it on, allowing the compressor oil to stabilise.

    Pre-filter

    The pre-filter installed at the air inlet helps capture larger airborne dust particles and protects the heat exchanger and internal components against rapid contamination.

    The filter should be inspected and cleaned regularly. A blocked filter reduces airflow and dehumidifier efficiency and may increase the load on the compressor and fan.

    Filter maintenance:
    • switch off the dehumidifier before removing the filter;
    • remove dust using a vacuum cleaner or soft brush;
    • if the filter is washed, allow it to dry completely before reinstalling it;
    • do not use aggressive solvents;
    • do not operate the dehumidifier without the filter installed correctly.

    Technical specifications

    Product type Industrial mobile condensation dehumidifier
    Maximum dehumidification capacity 60 l/day at 30 °C and 80% RH
    Recommended room area 60–120 m² with a ceiling height of approximately 3 m
    Airflow 850 m³/h
    Supply voltage 230 V AC
    Frequency 50 Hz
    Maximum input power 850 W
    Refrigerant R410A
    Operating temperature +5…+38 °C
    Humidity display range 30–90% RH
    Humidity control Microprocessor-controlled, adjustable
    Display Liquid-crystal display
    Automatic defrosting Yes
    Water tank capacity 10 l
    Outside diameter of drain connection Ø14 mm
    Condensate removal Into the tank or continuously through a drain hose
    Air intake Front
    Air outlet Side
    Filter High-density pre-filter
    Fan type Centrifugal
    Compressor protection after switch-on 3-minute start delay
    Mobility Castors with locks
    Dimensions 400×370×700 mm
    Weight 35 kg

    Main features

    • Dehumidification capacity up to 60 l/day – at 30 °C and 80% RH.
    • 850 m³/h airflow – for larger rooms.
    • Recommended area of 60–120 m² – with a ceiling height of approximately 3 m.
    • Automatic humidity control – according to the set RH level.
    • LCD display – for displaying current humidity and operating status.
    • Automatic defrosting – for operation in cooler rooms.
    • 10 l water tank – with a full-tank warning.
    • Continuous drainage – through a Ø14 mm hose.
    • Pre-filter – for capturing dust.
    • 3-minute compressor protection – after switch-on.
    • Metal housing with anti-corrosion coating.
    • Castors with locks – for convenient movement.

    Where can it be used?

    • In warehouses – to protect goods and packaging against moisture.
    • In production areas – to reduce process-related humidity.
    • In workshops and garages – to reduce condensation and the risk of corrosion.
    • In basements – to control elevated air humidity.
    • At construction and renovation sites – to accelerate room drying.
    • In archives and paper warehouses – to protect documents and raw materials.
    • In printing facilities – to control paper storage conditions.
    • In pharmaceutical and laboratory areas – where a specified humidity level must be maintained.
    • In tobacco, textile or timber warehouses – to regulate humidity conditions.
    • In greenhouses and technical rooms – where the conditions are within the unit's operating limits.

    Operating procedure

    1. Position the dehumidifier upright. Choose a level and stable surface.
    2. Lock the castors. The unit must not move by itself during operation.
    3. Leave space for air circulation. Do not obstruct the front air inlet or side outlet.
    4. Check the filter and water tank. They must be installed correctly.
    5. Choose the condensate removal method. Use the water tank or connect a drain hose.
    6. Connect the unit to a 230 V mains supply. The electrical socket must be earthed and suitable for the unit's load.
    7. Set the desired humidity. Select an RH value suitable for the intended use of the room.
    8. Allow the compressor to start. A protective delay of up to 3 minutes may operate after switch-on.
    9. Monitor the display. Check the humidity reading, water tank and any fault indications.
    10. Carry out regular maintenance. Clean the filter and water tank and inspect the drain hose.

    Usage and safety notes

    • Use only with a 230 V AC, 50 Hz mains supply.
    • The unit must be connected to an earthed socket.
    • Do not use outdoors or in locations exposed to rainunless an appropriate IP protection rating is specified.
    • Do not use below +5 °C or above +38 °C.
    • Do not obstruct the air inlet or outlet.
    • Do not move the unit while the compressor is operating.
    • Disconnect the power before cleaning or maintenance.
    • Do not operate without the air filter.
    • Do not allow water to reach electrical components.
    • Do not bend or pinch the drain hose.
    • Do not dismantle the refrigerant system yourself.
    • Repairs must be carried out by a qualified specialist.

    Maintenance

    • Clean the air filter regularly, especially in dusty rooms.
    • Empty and wash the water tankto prevent dirt and odours from developing.
    • Check the drain hose – it must not be blocked or kinked.
    • Clean the housing with a damp, soft cloth.
    • Do not use petrol, acetone or aggressive solvents.
    • Listen for changes in the sound of the compressor and fan. Unusual noise may indicate a fault.
    • If the dehumidifier will not be used for a long period, store it clean, dry and upright.

    FAQ – frequently asked questions

    Will the dehumidifier always collect 60 litres per day?
    No. The 60 l/day capacity is specified at 30 °C and 80% relative humidity. Under other conditions, the amount collected will be lower.
    What size room is it intended for?
    The stated recommended area is 60–120 m² with a room height of approximately 3 m. Actual suitability depends on the humidity level and room conditions.
    Can the desired humidity level be set?
    Yes. The microprocessor controller allows the desired humidity level to be set and controls dehumidifier operation automatically.
    Does the unit have automatic defrosting?
    Yes. The system automatically detects frost formation and activates defrost mode when required.
    Can the condensate be drained directly into the wastewater system?
    Yes, using a suitable hose connected to the Ø14 mm drain connection, provided that the water can flow downwards by gravity.
    What happens when the water tank is full?
    A full-tank warning is activated and the dehumidifier stops automatically to prevent condensate from overflowing.
    Can it be used in an unheated warehouse during winter?
    Only if the ambient temperature does not fall below the specified +5 °C limit. Dehumidification capacity decreases at low temperatures.
    Is the dehumidifier easy to move?
    Castors with locks are fitted underneath, but the unit weighs 35 kg, so several people may be required when lifting it.
    Why does the compressor not start immediately?
    The unit includes an approximately 3-minute compressor start protection delay, which reduces damage caused by excessively frequent switching.
    Does the filter need to be replaced?
    The supplied information specifies a pre-filter. Its cleaning or replacement interval should be determined according to contamination and the operating instructions.
    Can it be used to dry rooms after renovation?
    Yes, provided that the room temperature and conditions meet the unit's requirements, but the dehumidifier does not replace suitable heating and ventilation.

    Industrial 60 l/day dehumidifier for larger rooms

    The mobile condensation dehumidifier is designed to control humidity in warehouses, production areas, workshops, basements and other indoor spaces of 60–120 m².

    A dehumidification capacity of up to 60 l/day and an airflow of 850 m³/h allow a large volume of air to be processed, while microprocessor control automatically maintains the set relative humidity.

    Condensate can be collected in the 10-litre tank or continuously discharged through a Ø14 mm drain hose. The full-tank warning, automatic shut-off and defrost function simplify everyday operation.

    The reinforced metal housing, pre-filter, centrifugal fan and lockable castors are designed for more intensive commercial and industrial use.

    The maximum capacity of 60 l/day is achieved only at 30 °C and 80% RH. When selecting a dehumidifier for a specific room, its volume, temperature, initial humidity, air exchange and continuous moisture sources must be considered.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.