Industrial modular socket panel | 2×CEE 16 A 5P 400 V + 4×230 V | space for 11 modules of protection | IP54 | Scame ENERBOX 633D.11WW
Code: ENERBOX 633.D11WW 2x16A+4x230VPrice 51.00 € VAT incl.( 42.15 € VAT excl. )Scame ENERBOX 633D.11WW – a sealed industrial panel with sockets (2×CEE 16 A 5P 400 V + 4×230 V) and space for 11 modules of protective devices. Degree of protection: IP54, mounting – wall-mounted (surface).
-
Industrial modular socket panel | 2×CEE 16 A 5P 400 V + 4×230 V | space for 11 modules of protection | IP54 | Scame ENERBOX 633D.11WW
Scame ENERBOX 633D.11WW – a sealed industrial panel with sockets (2×CEE 16 A 5P 400 V + 4×230 V) and space for 11 modules of protective devices. Degree of protection: IP54, mounting – wall-mounted (surface).
Key idea:
A compact solution for a garage or workshop: a 3-phase CEE 16 A socket for a machine or compressor and 230 V sockets for ordinary tools in one sealed enclosure. The space for 11 modules lets you protect the sockets directly in the panel.Sockets
2×CEE 16 A 5P 400 V + 4×230 VModules
11 mod. space for protectionDegree of protection
IP54Voltage
230/400 VHow it works
The panel is fixed to a wall and supplied with a 3-phase 230/400 V cable (3 phases, N, PE). The sockets are factory-installed in the enclosure.
Circuit breakers and an RCD are fitted in the modular space (11 mod.) – so each socket or socket group gets its own protection against overload, short circuit and residual current.
The result is a sealed IP54 distribution point where equipment is connected via industrial CEE and 230 V sockets, with the protection right there – visible and easy to reach.
Why choose Scame ENERBOX 633D.11WW?
Sockets and space for protection in one enclosure: no need to assemble a box, sockets and a modular panel separately. You can choose the protection exactly to suit the connected equipment.Technical specifications
Product type Modular panel with sockets Manufacturer / model Scame ENERBOX 633D.11WW Code ENERBOX 633.D11WW 2x16A+4x230V 3-phase sockets 2× CEE 16 A 5P 400 V Single-phase sockets 4× 230 V Modular space 11 modules Protective devices not installed; space for 11 modules of protective devices Degree of protection IP54 Network 230/400 V, 50 Hz Mounting wall-mounted (surface) Main functions
- 3-phase CEE sockets (2×16 A) – for machines, compressors.
- 4 single-phase 230 V sockets – for hand tools, chargers, lighting.
- Space for 11 modules – for circuit breakers and an RCD directly in the panel.
- IP54 protection – suitable for damp and dusty rooms.
- Wall mounting – a fixed, tidy socket point.
Where is it used?
- Garages and home workshops
- Wood and metal workshops
- Farm buildings
- Technical rooms
- Small production units
- Utility zones of commercial premises
Use by need
For the garage owner.
A 3-phase socket for a compressor or machine and ordinary sockets in one place.For the electrician.
A pre-assembled enclosure with sockets and 11 modules of space for protection shortens installation.For a small business.
A tidy, sealed socket point in a technical room.Practical application
If 3-phase machines or a compressor with a CEE 16 A plug have to be connected in a garage with ordinary tools used nearby, the panel is wall-mounted, circuit breakers and an RCD are fitted in the modular space, and all equipment is connected in one place.Pros
- Sockets and space for protection in one enclosure
- IP54 protection
- Space for 11 modules
- 3-phase and single-phase sockets together
- Protection can be chosen for the specific equipment
Cons / limitations
- Protective devices are not installed – they must be purchased and fitted separately
- No 32 A socket for heavy 3-phase equipment
- Does not replace the main distribution or metering board
- Installation must be carried out by a qualified electrician
Safety and installation notes
- Connection and installation of protection must be carried out by a qualified electrician.
- Protect each socket or socket group with a circuit breaker and the socket circuits with an RCD (30 mA).
- Select the supply cable cross-section for the total load and line length.
- IP54 sealing is ensured only with the lids closed and sealed cable glands used.
- Mount with the sockets facing down or sideways so that water does not enter the plugs.
Quick selection guide
230/400 V2×CEE 16 A4×230 V11 mod.IP54Suitable when you need:- 3-phase and single-phase sockets in one place
- Protection right next to the sockets
- A sealed IP54 solution
Check before use:- Which circuit breaker ratings and RCD you need
- That the equipment plugs match the CEE 16 A sockets
- That the supply cable matches the total load
Important reminder: The panel is supplied without protective devices – it must not be used without circuit breakers and an RCD.FAQ
Does the panel have circuit breakers?
No, there is space for 11 modules of protective devices.Which sockets are installed?
2×CEE 16 A 5P 400 V + 4×230 V.What is the degree of protection?
IP54.Can a welder be connected?
Only if its plug is CEE 16 A 5P and its current does not exceed 16 A.Where is the panel mounted?
On a wall or structure, surface-mounted.Who should install it?
A qualified electrician, who also fits the protection.Industrial modular socket panel | 2×CEE 16 A 5P 400 V + 4×230 V | space for 11 modules of protection | IP54 | Scame ENERBOX 633D.11WW
Scame ENERBOX 633D.11WW – an industrial IP54 panel with 2×CEE 16 A 5P 400 V + 4×230 V sockets and space for 11 modules of protection – for garages, workshops, farms and technical rooms.
Published: 2026-11-15 · Data verified against the manufacturer / supplier specification: 2026-11-15
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThe IP protection class indicates the device's resistance to environmental factors.

The first digit indicates protection against dust and solid objects.
The second digit indicates protection against moisture.First digit values:
X — Untested;
0 — No protection;
1 — Protected against solid objects larger than 50 mm;
2 — Protected against solid objects larger than 12.5 mm;
3 — Protected against solid objects larger than 1 mm;
4 — Protected against solid objects larger than 1 mm;
5 — Dust protected;
6 — Totally dustproof.
Second digit values:X — Untested;
0 — No protection;
1 — Protected against vertically falling water drops;
2 — Protected against water drops falling at a 15º angle;
3 — Protected against rain falling at a 60º angle;
4 — Protected against water splashes;
5 — Protected against water jets;
6 — Protected against large amounts of water;
7 — Protected against short-term immersion in water up to 1 meter deep;
8 — Protected against long-term immersion in water up to 3 meters deep.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review