Products catalog

  • Industrial socket box | 1×16 A 5P 400 V + 2×Schuko 230 V | IP54 | SEZ ROSP 1631/S

    Code: 05462
    Barcode: 8584128105462

    SEZ socket box with 1×CEE 16 A 5P + 2×Schuko outlets, IP54. No MCBs or RCD inside – protection is installed in the supply board.

  • Industrial socket box | 1×16 A 5P 400 V + 2×Schuko 230 V | IP54 | SEZ ROSP 1631/S

    SEZ ROSP 1631/S – SEZ socket box with 1×CEE 16 A 5P 400 V and 2×Schuko 230 V 16 A. Enclosure protection – IP54.

    Key point:
    One box gives you a three-phase outlet for heavier equipment and 230 V domestic outlets for hand tools, lighting or chargers. There are no MCBs or RCD in the box, so all protection must be in the supply board.
    Outlets
    1×CEE 16 A 5P + 2×Schuko
    Protection
    IP54
    Current
    16 A
    Protective devices
    none

    How it works

    Supply: a 5-core cable (L1, L2, L3, N, PE) is brought in through a TVM 16 gland and connected inside the box. A cable with plug is not listed in the manufacturer data – the installer selects it.

    Outlets: the CEE 16 A 5P outlet receives all three phases, N and PE (400 V), while the 2×Schuko outlets get one phase, N and PE (230 V).

    Protection: the box is unprotected (no MCBs or RCD). An MCB (not above 16 A) and a 30 mA RCD are installed in the supply board; IP54 applies only with the outlet lids closed.

    Why choose SEZ ROSP 1631/S?
    One three-phase cable gives you both 400 V and 230 V outlets without a separate board. All outlets are 16 A, which makes line protection simple to select.

    Technical specifications

    Product type Socket box
    Manufacturer / model SEZ DK a.s. (Slovakia) / ROSP 1631/S
    Series Mikro: ROSP – IP54, ROSPG – IP67
    400 V outlets 1× CEE 16 A 5P (3P+N+PE), 400 V, 6h
    230 V outlets 2× Schuko 16 A 230 V
    Rated voltage 400 V~ / 250 V~, 50 Hz
    Protective devices None (unprotected version, no MCBs or RCD)
    Switch None
    Degree of protection IP54 (with lids closed)
    Impact resistance IK10 (empty enclosure)
    Enclosure Plastic
    Supply connection TVM 16 gland, terminals inside
    Dimensions approx. 190 × 148 mm (per manufacturer drawing)
    Ambient temperature −25…+40 °C (catalogue data)
    Standards EN 61439-3; CEE outlets to EN 60309-2
    Total load not above the line breaker (≤16 A)

    Main functions

    • 1× CEE 16 A 5P 400 V – for three-phase tools, compressors, mixers, heaters
    • 2× Schuko outlets – for hand tools, lighting, chargers
    • IP54 enclosure – protection against dust and splashing water
    • IK10 – impact resistance of the empty enclosure
    • TVM 16 gland – sealed supply cable entry
    • No modules – simple design, protection stays in the supply board

    How does it differ from similar products?

    SEZ ROSP 1631 D/S (577) 1×16 A 5P + 2×Schuko, IP54, with holder – a smaller portable option.
    SEZ ROSPG 1631 D (2236) 1×16 A 5P + 2×230 V 16 A, IP67, with holder – for wet and dirty locations.
    Scame 686D.122 (4490) Another maker's 16 A 5P + 230 V box, IP54 – similar purpose, different enclosure.
    SEZ ROS 4/V-12 (573) 1×16 A 5P + 2×230 V 16 A with 0–1 switch, IP44 – when outlets must be switched off locally.

    Where is it used?

    • Garages and car service shops
    • Workshops and production areas
    • Farm buildings and barns
    • Temporary power for repairs and events
    • Construction work – fed from a site board
    • Outdoor work under cover

    Use by need

    Beginner.
    The box comes fully fitted – it needs a suitable cable and connection to a protected board. It is not an extension lead with breakers: leave the connection to an electrician.
    Experienced installer.
    Use a flexible rubber 5-core cable (e.g. H07RN-F) sized to the line; check phase sequence at the CEE outlets and PE continuity.
    Power engineer / designer.
    The box is an end point without internal protection: overload and short-circuit protection (not above 16 A) and a 30 mA RCD are designed into the supply board. For sites – HD 60364-7-704.

    Practical use

    In a car service shop the box is installed at the workstation: a three-phase compressor plugs into the CEE outlet, a lamp and grinder into the 230 V outlets. It is fed from the board through a 16 A MCB and a 30 mA RCD.

    Pros / advantages

    • Three-phase and domestic outlets in one enclosure
    • All outlets 16 A – protection is simple to select
    • Simple design without modules
    • IP54 enclosure and IK10
    • TVM 16 gland for cable entry

    Cons / limitations

    • No MCBs or RCD – protection must be in the supply board
    • No switch – for local switching choose SEZ ROS 4/V-12 (16 A) or ROS 4/V-10 (32 A)
    • Total load of all outlets is limited by the line breaker (up to 16 A), as the outlets have no separate protection
    • IP54 – not for water jets; for such conditions choose SEZ ROSPG 1631 D (IP67)

    Safety and installation notes

    • ⚡ Connection and testing must be done by a qualified electrician, with the supply switched off.
    • ⚡ There are no MCBs or RCD in the box: protect the supply line with an MCB sized to the cable, not above 16 A, and a 30 mA RCD. The total load of all outlets must not exceed the line breaker.
    • If the supply line is single-phase, the CEE 400 V outlet must not be used – it will not have 400 V; feed the box from a three-phase 5-core line.
    • The PE conductor of the Schuko outlets must be connected – check PE continuity to every outlet and phase sequence at the CEE outlet.
    • On construction sites feed the box only from a site distribution board (HD 60364-7-704).
    • IP54 applies only with the outlet lids closed and the cable entry tightened (TVM 16).

    Quick selection guide

    1×CEE 16 A 5P 400 V
    2×Schuko 16 A 230 V
    IP54 / IK10
    No MCBs or RCD
    Suitable when you need:
    • 400 V and 230 V outlets from one cable
    • A simple outlet point without modules
    • Work indoors or under cover
    Check before choosing:
    • Is there a ≤16 A MCB and a 30 mA RCD in the supply board
    • Is the cable 5-core and does it fit the cable entry
    • Do the loads have CEE 16 A 5P and Schuko plugs
    • Is a total load of 16 A enough
    Important reminder: The box does not replace a protective board: it has no MCBs or RCD. All protection must be in the supply board.
    ☝ Elsprendimai.eu recommends:

    FAQ

    Does the box contain MCBs or an RCD?
    No. The manufacturer lists it as an unprotected version, so an MCB (not above 16 A) and a 30 mA RCD must be in the supply board.
    Which supply cable should I use?
    A 5-core (L1, L2, L3, N, PE) flexible rubber cable, e.g. H07RN-F; the electrician selects the cross-section by protection and length. Check that its diameter fits the TVM 16 gland.
    Can it be fed from a single-phase line?
    No. The 230 V outlets would work, but there would be no 400 V at the CEE 5P outlet. The box is intended for three-phase supply.
    How does the D version differ?
    The D version has a holder for portable use; this version has no holder.
    What does /S mean?
    In SEZ designations the letter S marks Schuko-type 230 V outlets.
    Can it be used outdoors or on a construction site?
    IP54 protects against dust and splashes, but not against water jets. On sites – only when fed from a site board with an RCD (HD 60364-7-704).

    Sources: SEZ DK a.s. product page (https://www.sez.sk/produkty/rosp-1631/); catalogue K1.1 "Zásuvkové rozvodnice a bubny" (2017). Checked 2026-10-20.

    SEZ ROSP 1631/S – socket box 1×CEE 16 A 5P + 2×Schuko, IP54

    SEZ ROSP 1631/S – socket box (1×16 A 5P 400 V + 2×Schuko 230 V), IP54, no MCBs or RCD. Suitable for garages, workshops and temporary power supply.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals