Products catalog

  • Industrial switch-disconnector | 3P | 630A | FMD5 frame | ~690 V | IP20 | manual operation | Promfactor Baltic | FMD50630

    Code: FMD50630
    Barcode: 4772151002535

    FMD50630 – Promfactor Baltic industrial switch-disconnector 3P 630 A, ~690 V, IP20, in the FMD5 frame with FMC5 accessories, for safe isolation of panels and lines.

  • Industrial switch-disconnector | 3P | 630A | FMD5 frame | ~690 V | IP20 | manual operation | Promfactor Baltic | FMD50630

    FMD50630 – a Promfactor Baltic industrial three-pole switch-disconnector in the FMD5 frame with a rated current of 630 A. It is designed for manually switching on, switching off and isolating a three-phase circuit in distribution and incoming panels. The switch-disconnector has no thermal or electromagnetic release – it does not protect against overload and short circuit, so the circuit must be protected by a circuit breaker or fuses installed upstream. Insulation voltage Ui 800 V, rated voltage Un ~690 V, impulse voltage Uimp 8000 V, 50/60 Hz; degree of protection IP20, weight 6.70 kg. Compatible Promfactor FMC5/3U (FMD) accessories: auxiliary contact F/AX5R (right-hand) or F/AX5L (left-hand), 1NO+1NC; shunt trip F/SH5230R, 230 V, right-hand.

    Key idea:
    A switch-disconnector is a clear and reliable isolation point: a single handle simultaneously disconnects all three phases up to 630 A, so the control panel, line or equipment is isolated from the supply before repair or maintenance. Since FMD5 uses the same accessories as FMC5 circuit breakers, the switch-disconnector and circuit breaker are configured in the control panel using the same logic.
    Rated current
    630 A
    Number of poles
    3P
    Voltage
    Un ~690 V, Ui 800 V, Uimp 8000 V
    Housing / protection
    FMD5, IP20, 6.70 kg

    Operating principle

    The FMD50630 switch-disconnector is mounted in the panel on a mounting plate; supply cables or busbars are connected to the three input terminals and the load to the three output terminals. A protective device must be installed upstream of the switch-disconnector – a circuit breaker (e.g. FMC53U0630 of the same current) or fuses selected according to the cable and load parameters.

    When the handle is turned or switched, the contacts simultaneously connect or disconnect all three phases up to a rated current of 630 A. The position status can be transmitted to a controller or control room via the F/AX5R auxiliary contact, and with the F/SH5230R shunt trip release it can be switched off by a remote 230 V signal. The switch-disconnector is designed for ~690 V (50/60 Hz) networks, insulation voltage Ui 800 V, impulse withstand voltage Uimp 8000 V; FMD5 frame endurance – 1,000 electrical and 4,000 mechanical on/off cycles.

    Result – a clear isolation point for a three-phase circuit up to 630 A, enabling safe repair or maintenance and the use of common FMC5/FMD5 accessories in the control panel.

    Benefits FMD50630?
    630 A three-pole switch-disconnector in the FMD5 frame with shared FMC5/3U (FMD) accessories – uniform panel equipment for circuit breakers and switch-disconnectors, with the option to signal position and trip the circuit remotely.

    Technical specifications

    Product type Industrial switch-disconnector (load switch-isolator)
    Manufacturer / code Promfactor Baltic / FMD50630
    Series / frame FMD5 (FMD50400 … FMD50630)
    Number of poles 3P
    Rated current 630 A
    Barcode (EAN) 4772151002535
    Standard (according to the e-shop product page) IEC/EN 60947-2
    Operating frequency 50/60 Hz
    Insulation voltage (Ui) 800 V
    Rated voltage (Un) ~690 V
    Impulse voltage (Uimp) 8000 V
    Electrical strength 1 000 switching (on/off) cycles
    Mechanical endurance 4 000 switching (on/off) cycles
    Degree of protection IP20
    Ambient operating temperature -25…+55 °C
    Storage temperature -25…+70 °C
    Weight 6.70 kg
    Control manual, handle on the housing
    Overload / short-circuit protection none (a protective device upstream of the switch-disconnector is required)
    Auxiliary contact F/AX5R (right-hand) or F/AX5L (left-hand), 1NO+1NC
    Shunt trip release F/SH5230R, 230 V, right-hand
    Circuit breaker of the same current rating FMC53U0630 (FMC5/3U, 50 kA)

    Main functions

    • Three-pole isolation – a single handle simultaneously connects or disconnects all three phases up to 630 A.
    • Manual control – status and isolation are handled by the installer directly in the control panel, without additional control circuits.
    • For networks up to ~690 V – Ui 800 V and Uimp 8000 V – suitable for 400 V and 690 V industrial networks.
    • Isolation for repair – the line or control panel section is isolated from the supply before maintenance or equipment replacement.
    • Position signalling – auxiliary contact F/AX5R (right-hand) or F/AX5L (left-hand), 1NO+1NC transmits the status to a controller or control room.
    • Remote tripping – the F/SH5230R shunt trip release switches off the switch-disconnector with a 230 V signal – suitable for emergency disconnection.
    • Shared accessories with FMC5 – the same FMC5/3U (FMD) accessories also fit the FMC53U0630 circuit breaker – smaller stock.

    Where is it used?

    • Main distribution boards
    • 0.4 kV incomers and lines of transformer substations
    • Incoming panels of large buildings
    • Power control panels in industrial plants
    • Logistics and warehouse centres
    • Backup power (generator) circuits
    • Compensation equipment circuits

    On-demand operation

    For transformer substation installers.
    The 630 A switch-disconnector suits a 0.4 kV side incomer or outgoing power lines.
    For manufacturers of main panels for large buildings.
    630 A – the highest current of the FMD5 frame, covering most medium-sized building incomers.
    For installers of generators and backup power systems.
    A 630 A circuit can be isolated remotely by a 230 V signal via an F/SH5230R shunt trip.

    Practical application

    If the panel needs a separate three-phase isolation point for a line whose operating current does not exceed 630 A, then FMD50630 is installed downstream of the protective circuit breaker (e.g. FMC53U0630), all three phases are isolated with a single handle before repairs, and its position is transmitted to the controller via F/AX5R.

    Application guide: how it is used in practice

    FMD50630 adapts to different sites – only what is connected and which accessories are used changes:

    Site What is connected Result Installer's note
    Incoming control panel Incoming cable via a protective circuit breaker → FMD50630 → distribution busbars The whole control panel is isolated with a single handle The switch-disconnector does not protect – select the protective device according to the cable
    Line or equipment group Circuit supply up to 630 A via FMD50630 The circuit is isolated for repair without affecting other circuits Mark the isolated position and attach a warning sign
    Remotely monitored site F/AX5R contacts → PLC / BMS input Switch-disconnector position visible remotely Match the contact side (left / right) to the control panel layout
    Emergency disconnection Emergency button → F/SH5230R (230 V) The switch-disconnector is tripped by a remote signal Take the shunt trip supply from a reliable 230 V source

    How to select the current and frame of an FMD switch-disconnector

    Rated current / frame Recommended model
    100 A, FMD3 frame FMD30100 (smaller incomers, building panels)
    125 A, FMD3 frame FMD30125 (distribution boards, small incomers)
    160 A, FMD3 frame FMD30160 (building and workshop incomers)
    200 A, FMD3 frame FMD30200 (power panels, pumping stations)
    225 A, FMD3 frame FMD30225 (intermediate size between 200 and 250 A)
    250 A, FMD3 frame FMD30250 (highest current of the FMD3 frame)
    250 A, FMD4 frame FMD40250 (250 A in the FMD4 frame with FMC4 accessories)
    315 A, FMD4 frame FMD40315 (0.4 kV substation lines, workshop incomers)
    400 A, FMD4 frame FMD40400 (highest current of the FMD4 frame)
    400 A, FMD5 frame FMD50400 (400 A in the FMD5 frame with FMC5 accessories)
    500 A, FMD5 frame FMD50500 (main distribution boards)
    630 A, FMD5 frame FMD50630 (highest current of the FMD5 frame) ← this model
    800 A, FMD6 frame FMD60800 (main incomers, transformer substations)
    Rule: the rated current of the switch-disconnector must be no lower than the rating of the upstream protective device and the operating current of the circuit. Where the same current is available in two frames (250 A – FMD3 or FMD4; 400 A – FMD4 or FMD5), the smaller frame saves space, while the larger one allows the current to be increased later within the same frame and the use of larger-frame accessories. The switch-disconnector does not provide protection – protection is always provided by a circuit breaker or fuses.
    When to choose another solution: other currents in the same FMD5 frame – FMD50400, FMD50500; for protection at the same current – circuit breaker FMC53U0630; for modular circuits up to 125 A – FSD3 series modular switch-disconnectors (e.g. FSD34125); accessories – auxiliary contact F/AX5R (right-hand) or F/AX5L (left-hand), 1NO+1NC; shunt trip release F/SH5230R, 230 V, right-hand.

    Pros

    • Three-pole isolation up to 630 A with a single handle
    • Shared FMC5/3U (FMD) accessories with FMC5 circuit breakers
    • Position contact F/AX5R (right-hand) or F/AX5L (left-hand), 1NO+1NC
    • Remote tripping with the F/SH5230R release
    • Clear isolation point for repair and maintenance
    • Un ~690 V, Ui 800 V, Uimp 8000 V; 1,000 electrical / 4,000 mechanical cycles

    Cons / limitations

    • Does not protect against overload and short circuit – a circuit breaker or fuses are required upstream of the switch-disconnector
    • Auxiliary contacts, releases and control units are ordered separately
    • IP20 – install only in a closed panel or cabinet; operating temperature -25…+55 °C
    • The price list has no remote control unit for the FMD5 frame – for remote control choose FMD4 (MROM34) or FMD3 (MROM33)
    • The price list has no separate alarm contact for the FMD5 frame – use F/AX5R for status indication

    Safety and installation notes

    • Installation and connection must be carried out by a qualified electrician after disconnecting the supply and verifying the absence of voltage.
    • A switch-disconnector is not a protective device – the circuit must be protected by a circuit breaker or fuses selected according to the cable and load.
    • Tighten the terminal screws to the torque specified by the manufacturer and use cables or busbars with a cross-section matching the current.
    • Before starting work, lock the isolated switch-disconnector or mark it with a warning sign and verify the absence of voltage on the output side.
    • Install accessories (contacts, releases, control units) only after the switch-disconnector and its circuits have been de-energised.

    Quick selection guide

    3P
    630 A
    ~690 V
    IP20
    FMD5
    Manual control
    FMC5 accessories
    Suitable when you need:
    • isolate a three-phase circuit or control panel with an operating current of up to 630 A;
    • create a clear isolation point for repair and maintenance;
    • configure the control panel with FMC5 circuit breakers and common accessories.
    Check before use:
    • whether the operating current of the circuit and the rating of the protective device upstream of the switch-disconnector do not exceed 630 A;
    • whether the circuit is protected by a circuit breaker or fuses;
    • which accessories are required: position contact, release.
    Important reminder: FMD50630 is a switch-disconnector, not a circuit breaker – it does not protect against overload and short circuit, and accessories are ordered separately.

    FAQ

    Does FMD50630 protect against short circuits?
    No, FMD50630 has no protective releases, so a circuit breaker or fuses must be installed upstream of it.
    What is the rated current of FMD50630?
    The rated current of FMD50630 is 630 A, the rated voltage is ~690 V, and the switch-disconnector isolates three poles.
    Which auxiliary contacts are suitable?
    F/AX5R (right-hand) or F/AX5L (left-hand), 1NO+1NC are suitable.
    Can the switch-disconnector be switched off remotely?
    Yes, with the F/SH5230R shunt trip release, 230 V, right-hand.
    How does FMD differ from FMC?
    FMC5 is a circuit breaker with overcurrent protection, while FMD5 is a switch-disconnector of the same frame series without protection, using shared accessories.
    How many operations can the switch-disconnector withstand?
    The FMD5 frame switch-disconnector withstands 1 000 electrical and 4 000 mechanical switching (on/off) cycles.

    Industrial switch-disconnector | 3P | 630A | FMD5 frame | ~690 V | IP20 | manual operation | Promfactor Baltic | FMD50630

    Promfactor Baltic FMD50630 – industrial three-pole switch-disconnector 630 A in an FMD5 frame with manual operation, compatible with FMC5/3U (FMD) accessories: auxiliary contacts, shunt trip release – for isolating incoming and distribution control panels, lines and equipment groups.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information