Products catalog

  • Industrial Ultrasonic Air Humidifier | 300W | 230V | 3kg/h | 680x320x470mm | White

    Code: ES-MCH-03

    Mobile industrial ultrasonic air humidifier is designed to increase relative air humidity in greenhouses, mushroom-growing rooms, printing facilities, warehouses, production areas and other larger indoor spaces. The high-frequency ultrasonic atomiser breaks water into fine droplets smaller than 5 μm and produces a cool mist.

    The humidification capacity reaches 3 kg of water per hour. The integrated digital control system, LCD display and humidity sensor allow ambient conditions to be monitored, the desired humidity level to be set and either automatic or manual operating mode to be selected.

    The unit is powered from a 230 V AC, 50 Hz mains supply and has a power consumption of 300 W. Mist is discharged through one Ø110 mm connection, to which a suitable mist-distribution duct can be connected. 

  • Industrial ultrasonic air humidifier – 3 kg/h, 300 W, 230 V, automatic humidity control, Ø110 mm mist outlet

    Mobile industrial ultrasonic air humidifier is designed to increase relative air humidity in greenhouses, mushroom-growing rooms, printing facilities, warehouses, production areas and other larger indoor spaces. The high-frequency ultrasonic atomiser breaks water into fine droplets smaller than 5 μm and produces a cool mist.

    The humidification capacity reaches 3 kg of water per hour. The integrated digital control system, LCD display and humidity sensor allow ambient conditions to be monitored, the desired humidity level to be set and either automatic or manual operating mode to be selected.

    The unit is powered from a 230 V AC, 50 Hz mains supply and has a power consumption of 300 W. Mist is discharged through one Ø110 mm connection, to which a suitable mist-distribution duct can be connected.

    Humidification capacity
    3 kg/h
    Water droplet size
    Less than 5 μm
    Power consumption
    300 W
    Power supply
    230 V AC, 50 Hz
    Humidity range
    10–90% RH
    Sensor accuracy
    ±3% RH
    Mist outlet
    1 × Ø110 mm
    Control
    Automatic or manual

    Ultrasonic humidification principle

    The unit uses a high-frequency ultrasonic atomiser. Vibrations on the water surface create very fine droplets, which are discharged into the room together with the airflow as a cool mist.

    The particle size is less than 5 μm. Fine droplets disperse more easily through the air and, under suitable room conditions, evaporate without leaving large water droplets on surrounding surfaces.

    Ultrasonic humidification does not heat the water, so the discharged mist is cool. The unit is not designed to heat the room or generate high-temperature steam.

    Distribution of fine droplets:
    Although droplets smaller than 5 μm help distribute moisture more evenly, the final result depends on room air circulation, ventilation, temperature, mist outlet location and the layout of the ducting used.

    Humidification capacity of 3 kg/h

    The maximum stated humidification capacity is 3 kg of water per hour. Since 1 kg of water is approximately equal to 1 litre, this means that at maximum output the unit can atomise up to approximately 3 litres of water per hour.

    The actual amount of moisture entering and evaporating into the room air depends on temperature, initial relative humidity, ventilation, airflow and control settings.

    Excessive humidification may cause condensation on walls, ceilings, pipes, plants or equipment, so the humidity level must be set according to the requirements of the specific process and room.

    Automatic and manual control

    The humidifier can operate in automatic or manual mode. In automatic mode, the integrated humidity sensor monitors the ambient relative humidity, while the controller regulates humidification according to the value set by the user.

    When the relative humidity is below the set value, the unit begins producing mist. Once the selected level is reached, humidification stops or is reduced according to the control algorithm.

    Manual mode allows humidification to be switched on directly, independently of automatic humidity maintenance. This mode can be used during start-up, testing or short-term intensive humidification.

    Control functions:
    • automatic humidity maintenance;
    • manual humidification mode;
    • setting the desired humidity level;
    • displaying the current humidity;
    • timer setting function;
    • LCD display and control buttons.

    High-accuracy humidity sensor

    The integrated humidity sensor is designed to measure ambient relative humidity and control the automatic humidification process. The stated sensor accuracy is ±3% RH.

    Sensor readings may be affected by the mist flow, direct exposure to water, condensation, air temperature and an unsuitable installation location. The humidity sensor should not be installed directly in the mist outlet zone.

    Sensor reading note:
    Where particularly accurate and documented humidity control is required, an additional calibrated independent hygrometer is recommended.

    One Ø110 mm mist outlet

    The humidifier has one Ø110 mm mist outlet connection. A pipe or duct of a suitable diameter can be connected to it to direct the mist towards the required area of the room.

    Ducting can be used to distribute the mist higher above plants, into a process area or farther away from the unit itself. The duct should be as short as possible, without unnecessary bends or places where condensate could collect.

    Duct installation note:
    A long, narrow duct or one with many bends may reduce mist flow. Condensate formed inside the duct must be drained safely so that it cannot flow back into the electrical parts of the unit.

    Mobile housing with castors

    The humidifier has universal castors, allowing it to be moved between different areas of the room. The front castors are fitted with brakes, enabling the unit to be secured in the selected position.

    Before moving the unit, it is recommended to switch it off, disconnect it from the mains and check that water cannot spill. The unit must be used on a level and stable surface.

    Technical specifications

    Product type Industrial ultrasonic air humidifier
    Humidification capacity 3 kg/h
    Humidification technology High-frequency ultrasonic atomisation
    Atomised droplet size Less than 5 μm
    Supply voltage 230 V AC
    Frequency 50 Hz
    Power consumption 300 W
    Control method Automatic or manual
    Control display LCD display and control panel
    Specified humidity range 10–90% RH
    Humidity sensor accuracy ±3% RH
    Timer setting Timer setting function specified
    Number of mist outlets 1
    Mist outlet diameter Ø110 mm
    Mobility Universal castors, front castors with brakes
    Dimensions 680×320×470 mm

    Main features

    • 3 kg/h humidification capacity – for industrial and agricultural premises.
    • Ultrasonic technology – for generating a cool mist flow.
    • Droplets smaller than 5 μm – for more even distribution.
    • Automatic humidity control.
    • Manual operating mode.
    • Specified range of 10–90% RH.
    • Sensor accuracy of ±3% RH.
    • LCD display and control panel.
    • Timer setting function.
    • One Ø110 mm mist outlet.
    • 300 W power consumption.
    • Castors with brakes – for convenient movement and secure positioning.

    Where can it be used?

    • In greenhouses – to maintain the relative humidity required by plants.
    • In mushroom-growing rooms – to create a humid microclimate.
    • In nurseries – for young plants and seedlings.
    • In agricultural buildings – for automatic humidity control.
    • In printing facilities – to regulate the humidity of paper and the production environment.
    • In textile production – to reduce electrostatic charge and dry air.
    • In woodworking facilities – to maintain the required process microclimate.
    • In warehouses – where stored materials require higher humidity.
    • In electronics and production areas – to reduce dry air and static electricity.
    • In other industrial premises – where automatic cool-mist humidification is required.

    Operating procedure

    1. Position the unit securely. Use a level, dry and firm surface.
    2. Lock the front castors. The unit must not move during operation.
    3. Prepare the water supply. Use clean water that meets the unit's requirements.
    4. Connect the mist duct. If a pipe is used, it must fit the Ø110 mm outlet.
    5. Keep the humidity sensor away from direct mist. This helps obtain more representative room humidity readings.
    6. Connect the unit to a 230 V mains supply. Use an earthed socket suitable for the required load.
    7. Select the control mode. Choose automatic or manual operation.
    8. Set the desired humidity. Select the value according to the needs of the plants, products or process.
    9. Set the timer if required. Use the timer function provided on the control panel.
    10. Monitor operation. Check mist distribution, condensation formation and humidity readings.

    Water quality and hygiene

    An ultrasonic humidifier can release minerals, impurities and microorganisms contained in the water into the air together with the water droplets. It is therefore very important to use clean water and clean the water system regularly.

    When hard water is used, white mineral dust may form on surrounding surfaces and limescale may accumulate on the ultrasonic elements. This may reduce humidification capacity and shorten the service life of the unit.

    Water quality recommendation:
    Use clean, filtered or demineralised water. Do not use contaminated, salty, chemically aggressive or biologically unsafe water.

    Usage and safety notes

    • Use only with a 230 V AC, 50 Hz mains supply.
    • The unit must be connected to an earthed socket.
    • Protect the control and electrical parts against direct exposure to water.
    • Do not use contaminated water or water with an unsuitable chemical composition.
    • Do not direct mist straight at electrical equipment, walls or ceilings.
    • Do not allow condensation to form in the room.
    • Do not obstruct the mist outlet.
    • Do not use a duct that is too narrow or blocked.
    • Disconnect the unit from the mains before cleaning.
    • Do not dismantle the ultrasonic generator or control electronics.
    • Repairs must be carried out by a qualified specialist.

    Maintenance

    • Replace or top up the water regularlyand do not allow it to stand for long periods.
    • Clean the water tank and pipeworkto prevent deposits from accumulating.
    • Remove limescale from the ultrasonic elements in accordance with the operating instructions.
    • Check the Ø110 mm mist outlet and duct – they must not be blocked.
    • Clean the humidity sensorwhile protecting it against mechanical damage.
    • Clean the housing with a soft, slightly damp cloth.
    • Do not use petrol, acetone or aggressive solvents.
    • If the unit will not be used for a long period, empty, clean and dry it completely.

    FAQ – frequently asked questions

    Does the humidifier produce hot steam?
    No. The ultrasonic system generates a cool mist without heating the water to boiling point.
    What size are the mist droplets?
    They are smaller than 5 μm.
    Can the desired humidity be set?
    Yes. The unit has automatic digital control and a humidity setting function.
    Can it be operated manually?
    Yes. Automatic and manual modes can be selected.
    What is the accuracy of the humidity sensor?
    The accuracy is ±3% relative humidity.
    Can a mist-distribution duct be connected?
    Yes. The unit has one Ø110 mm mist outlet to which a suitable duct can be connected.
    Can ordinary tap water be used?
    It depends on its hardness. Hard water may cause limescale deposits and white mineral dust, so filtered or demineralised water is safer to use.
    Is the unit easy to move?
    Yes. It has universal castors, and the front castors are fitted with brakes.

    Industrial 3 kg/h ultrasonic air humidifier

    The ultrasonic air humidifier is designed for greenhouses, mushroom-growing facilities, printing, textile, production and other premises where automatic maintenance of relative humidity is required.

    The high-frequency atomiser produces cool-mist droplets smaller than 5 μm, while the maximum stated humidification capacity is 3 kg of water per hour.

    The LCD display, humidity sensor with ±3% RH accuracy, and automatic and manual modes allow the humidification process to be monitored and adjusted.

    One Ø110 mm mist outlet allows a distribution duct to be connected, while universal castors and front brakes make the unit easier to move and position securely.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals

    privacy policy