    Weidmüller RCI424T30 is an interface relay with a 230 V AC coil and 2CO changeover contacts rated 8 A. It receives a weak control signal and switches another circuit through a galvanically isolated contact.

    Key point:
    A relay with a 230 V AC coil takes its control signal straight from a mains circuit – a programmer, thermostat, timer or switch. It is the simplest way to multiply contacts or isolate circuits in residential and commercial panels.
    Contacts
    2CO
    Rated current
    8 A / 240 V AC
    Coil voltage
    230 V AC (0.75 VA)
    Indication
    red LED

    Operating principle

    The relay plugs into a suitable socket on a DIN rail (or is soldered to a PCB). The control voltage is applied to coil terminals A1–A2.

    When current flows through the coil, the electromagnet pulls the armature and switches the contacts: the common contact (COM) leaves NC and closes to NO. When the control voltage drops, a spring returns the contacts to their initial position.

    Coil and contact circuits are galvanically isolated, so a weak control signal safely controls a circuit at another voltage.

    Why choose Weidmüller RCI424T30?
    Weidmüller RCI424T30 – a 2CO 8 A relay with a 230 V AC coil, red LED and AgNi contacts. Coil power is only 0.75 VA.

    Technical specifications

    Product type Interface (control) relay
    Manufacturer / code Weidmüller RCI424T30 (8870230000)
    Series Weidmüller RIDERSERIES RCI
    Coil voltage 230 V AC
    Coil power 0.75 VA; 3.2 mA
    Contacts 2CO
    Contact material AgNi 90/10
    Rated current 8 A (inrush current 15 A / 4 s)
    Max. switching voltage 240 V AC (max. 400 V AC)
    Rated load AC1 2000 VA
    DC1 breaking capacity 192 W / 24 V DC
    Insulation coil–contacts 5 kV; ≥8 mm
    Operate / release time ≤10 ms / ≤6 ms
    Operating temperature −40…+70 °C
    Dimensions 13 × 29 × 25.6 mm
    Mounting plug-in (socket) or PCB
    Indication red LED
    Standards / approvals IEC 61810-1, UL 508, cURus, CSA

    Main functions

    • Galvanic isolation – the control circuit is protected from load circuit disturbances.
    • 2CO contacts – one signal can control a load and return a status signal.
    • Signal amplification – a weak PLC or controller output switches a 8 A load.
    • Plug-in mounting – fast replacement without disconnecting wires.
    • Voltage conversion – control at one voltage, load at another (e.g. 24 V → 230 V).

    Where is it used?

    • Control from a 230 V programmer, thermostat or timer
    • Contact multiplication in residential and commercial panels
    • Contactor coil control
    • Control of lighting and ventilation groups
    • Interlocks between circuits
    • Control of pumps and heating equipment
    • Alarm and signalling circuits

    Use by need

    Electrician.
    Contact multiplication and circuit isolation without a separate control supply.
    Building manager.
    Control lighting, ventilation or pumps from an existing programmer.
    Panel assembler.
    Standard plug-in relay with widely available sockets.

    Practical application

    If a 230 V timer has to switch two separate circuits at once (e.g. ventilation and lighting), the timer output connects to the 230 V AC relay coil, and both circuits go through separate relay contacts that are galvanically isolated from each other.

    Pros

    • Galvanic isolation of control and load circuits
    • Plug-in mounting – fast replacement
    • Standard contact numbering
    • Wide choice of sockets and accessories
    • Red LED status indicator
    • Low coil power – 0.75 VA

    Cons / limitations

    • No test button
    • Not a protective device – does not protect against overload or short circuit
    • Inductive loads need a suppression circuit (diode, RC or varistor)
    • Use a contactor for motors and large loads

    Safety and installation notes

    • Disconnect the supply before installation and verify absence of voltage.
    • Check coil voltage and type (AC/DC) – a wrong coil will not operate or will burn out.
    • Suppress inductive loads (coils, valves) with a diode (DC) or RC circuit / varistor (AC).
    • Protect the contact circuit with a circuit breaker or fuse.
    • Do not exceed rated current and voltage; in DC circuits allow for the lower breaking current.

    Quick selection guide

    2CO
    8 A / 240 V AC
    230 V AC
    red LED
    Suitable when you need:
    • control from a 230 V programmer, thermostat or timer
    • to multiply contacts in a residential panel
    • to build interlocks between circuits
    Check before use:
    • coil voltage and type (AC or DC)
    • load type and current (resistive, inductive, LED)
    • that you have a compatible socket: Weidmüller RIDERSERIES sockets (confirm compatibility by relay code)
    Important reminder: an interface relay is not a protective device. It does not protect against overload or short circuit, and motors and large loads require a contactor.

    FAQ

    Do I need a socket?
    Yes, a plug-in relay needs a socket for DIN rail mounting; compatible: Weidmüller RIDERSERIES sockets (confirm compatibility by relay code).
    Can the coil be powered at another voltage?
    No, the coil must match the control voltage and type – 230 V AC.
    Is it suitable for driving a contactor coil?
    Yes, that is one of the most common uses; a suppression circuit is recommended.
    Can a motor be connected directly?
    No, connect the motor through a contactor with thermal protection; the relay drives the contactor coil.
    What does 2CO mean?
    It is the number of changeover contact sets; each has COM, NC and NO.
    Do you help with selection?
    Yes, send us a diagram or equipment list – we will select relays, sockets and contactors.

    Interface relay | 2CO | 8 A | coil 230 V AC | plug-in / PCB | Weidmüller RCI424T30

    Weidmüller RCI424T30 – interface relay with 230 V AC coil and 2CO contacts 8 A, for signal isolation, contact multiplication and control of contactors and valves in automation and electrical panels.

    Published: 2026-11-05 · Data verified against the manufacturer datasheet: 2026-11-05

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • privacy policy

    Information