Products catalog

  • Relay socket | Finder 55.32 / 55.34 | 10 A | 250 V | DIN 35 mm | Finder 94.04SPA

    Code: 94.04SPA

    Finder 94.04SPA – socket for Finder 55.32 / 55.34 relays, mounted on DIN rail. Screw terminals; the relay can be replaced without disconnecting wires.

  • Relay socket | Finder 55.32 / 55.34 | 10 A | 250 V | DIN 35 mm | Finder 94.04SPA

    Finder 94.04SPA is a socket for Finder 55.32 / 55.34 relays. The relay plugs into the socket and the wires connect to the socket screw terminals, so the relay can be replaced without disturbing the wiring.

    Key point:
    A plug-in relay cannot be connected without a socket. A socket with screw terminals lets you mount the relay on a DIN rail and replace a faulty relay in seconds without disconnecting wires.
    Compatible relays
    Finder 55.32 / 55.34
    Rated current
    10 A / 250 V
    Number of pins
    14 (4CO)
    Retaining clip
    094.91.3

    Operating principle

    The socket snaps onto a 35 mm DIN rail. Coil (A1–A2) and contact wires connect to the screw terminals according to the diagram marked on the socket.

    The relay is plugged in and secured with the clip so it does not fall out due to vibration.

    When needed, the relay can be pulled out and replaced without disconnecting a single wire.

    Why choose Finder 94.04SPA?
    Finder 94.04SPA – a socket for 55.32 / 55.34 relays and 85 series timers, supplied with the 094.91.3 plastic clip. Terminals accept up to 6 mm² solid wire.

    Technical specifications

    Product type Relay socket for DIN rail mounting
    Manufacturer / code Finder 94.04SPA
    Compatible relays Finder 55.32, 55.34; timers 85.02/85.03/85.04
    Number of pins 14 (4CO)
    Rated current 10 A
    Max. switching voltage 250 V
    Terminals screw (box clamp)
    Wire cross-section solid 1 × 6 / 2 × 2.5 mm²; stranded 1 × 4 / 2 × 2.5 mm²
    Tightening torque 0.5 Nm
    Insulation coil–contacts 2 kV AC
    Operating temperature −40…+70 °C
    Protection class IP20
    Mounting 35 mm DIN rail or screw mounting
    Retaining clip 094.91.3 (plastic, included)
    Accessories 99.02, 86.30, 094.06

    Main functions

    • Screw terminals – reliable wire connection in the panel.
    • DIN rail – mounting next to other modular devices.
    • Fast relay replacement – wires stay connected.
    • Marked terminals – clear coil and contact numbering.
    • Retaining clip – the relay does not fall out due to vibration.

    Where is it used?

    • Automation and control panels
    • PLC input/output interfaces
    • Industrial machinery control cabinets
    • Building automation panels
    • HVAC control panels
    • Repair and replacement of faulty relays

    Use by need

    Panel builder.
    Neat relay mounting on DIN rail with clear terminal numbering.
    Maintenance technician.
    Replace the relay without disconnecting wires – shorter downtime.
    Automation integrator.
    A standard socket that fits the whole relay series.

    Practical application

    If an interface relay fails in the panel, it is simply pulled out of the socket and a new one plugged in – the wires stay on the socket terminals, the circuit does not change and downtime is a few minutes.

    Pros

    • DIN rail mounting
    • Relay replacement without disconnecting wires
    • Clearly marked terminals
    • 094.91.3 clip included
    • 99.02 modules and 86.30 timer modules

    Cons / limitations

    • With an 85.04 timer the circuit is limited to 7 A
    • Fits only the specified relay series
    • Socket current is also limited by the relay ratings – the lower value applies

    Safety and installation notes

    • Install and replace relays only with the supply disconnected.
    • Tighten wires to the recommended torque; do not exceed the terminal cross-section.
    • Use only compatible relays and retaining clips.
    • Protect the socket circuit with a circuit breaker or fuse.

    Quick selection guide

    55.32 / 55.34
    10 A / 250 V
    IP20
    094.91.3
    Suitable when you need:
    • to mount a plug-in relay on DIN rail
    • to replace relays without disconnecting wires
    • to assemble an automation panel neatly
    Check before use:
    • that the relay series fits this socket
    • wire cross-section and terminal type
    • space in the panel (width, height under the cover)
    Important reminder: a socket is not a protective device – the circuit must be protected by a circuit breaker or fuse.

    FAQ

    Which relays fit?
    This socket is designed for Finder 55.32 / 55.34 relays.
    Is the relay included?
    No, the relay is sold separately.
    How is it mounted?
    It snaps onto a 35 mm DIN rail.
    Can the relay be replaced without disconnecting wires?
    Yes, that is the main advantage of a socket.
    Does the socket protect the circuit?
    No, the circuit must be protected by a circuit breaker or fuse.
    Do you help with selection?
    Yes, send us the relay code – we will select a suitable socket and accessories.

    Relay socket | Finder 55.32 / 55.34 | 10 A | 250 V | DIN 35 mm | Finder 94.04SPA

    Finder 94.04SPA – socket for Finder 55.32 / 55.34 relays, DIN rail mounting, with screw terminals for fast relay replacement in automation panels.

    Published: 2026-11-05 · Data verified against the manufacturer datasheet: 2026-11-05

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Interface relay | 2CO | 8 A | coil 24 V DC | plug-in | Schneider Electric RSB2A080BD
    Code: RSB 2A080BD

    Schneider Electric RSB2A080BD – interface relay with 2CO contacts (8 A) and 24 V DC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.

    Price 2.94 € VAT incl.
    ( 2.43 € VAT excl. )
  • privacy policy