Relay socket | Finder 55.32 / 55.34 | 10 A | 250 V | DIN 35 mm | Finder 94.04SPA
Code: 94.04SPAPrice 3.03 € VAT incl.( 2.50 € VAT excl. )Finder 94.04SPA – socket for Finder 55.32 / 55.34 relays, mounted on DIN rail. Screw terminals; the relay can be replaced without disconnecting wires.
-
Relay socket | Finder 55.32 / 55.34 | 10 A | 250 V | DIN 35 mm | Finder 94.04SPA
Finder 94.04SPA is a socket for Finder 55.32 / 55.34 relays. The relay plugs into the socket and the wires connect to the socket screw terminals, so the relay can be replaced without disturbing the wiring.
Key point:
A plug-in relay cannot be connected without a socket. A socket with screw terminals lets you mount the relay on a DIN rail and replace a faulty relay in seconds without disconnecting wires.Compatible relays
Finder 55.32 / 55.34Rated current
10 A / 250 VNumber of pins
14 (4CO)Retaining clip
094.91.3Operating principle
The socket snaps onto a 35 mm DIN rail. Coil (A1–A2) and contact wires connect to the screw terminals according to the diagram marked on the socket.
The relay is plugged in and secured with the clip so it does not fall out due to vibration.
When needed, the relay can be pulled out and replaced without disconnecting a single wire.
Why choose Finder 94.04SPA?
Finder 94.04SPA – a socket for 55.32 / 55.34 relays and 85 series timers, supplied with the 094.91.3 plastic clip. Terminals accept up to 6 mm² solid wire.Technical specifications
Product type Relay socket for DIN rail mounting Manufacturer / code Finder 94.04SPA Compatible relays Finder 55.32, 55.34; timers 85.02/85.03/85.04 Number of pins 14 (4CO) Rated current 10 A Max. switching voltage 250 V Terminals screw (box clamp) Wire cross-section solid 1 × 6 / 2 × 2.5 mm²; stranded 1 × 4 / 2 × 2.5 mm² Tightening torque 0.5 Nm Insulation coil–contacts 2 kV AC Operating temperature −40…+70 °C Protection class IP20 Mounting 35 mm DIN rail or screw mounting Retaining clip 094.91.3 (plastic, included) Accessories 99.02, 86.30, 094.06 Main functions
- Screw terminals – reliable wire connection in the panel.
- DIN rail – mounting next to other modular devices.
- Fast relay replacement – wires stay connected.
- Marked terminals – clear coil and contact numbering.
- Retaining clip – the relay does not fall out due to vibration.
Where is it used?
- Automation and control panels
- PLC input/output interfaces
- Industrial machinery control cabinets
- Building automation panels
- HVAC control panels
- Repair and replacement of faulty relays
Use by need
Panel builder.
Neat relay mounting on DIN rail with clear terminal numbering.Maintenance technician.
Replace the relay without disconnecting wires – shorter downtime.Automation integrator.
A standard socket that fits the whole relay series.Practical application
If an interface relay fails in the panel, it is simply pulled out of the socket and a new one plugged in – the wires stay on the socket terminals, the circuit does not change and downtime is a few minutes.Pros
- DIN rail mounting
- Relay replacement without disconnecting wires
- Clearly marked terminals
- 094.91.3 clip included
- 99.02 modules and 86.30 timer modules
Cons / limitations
- With an 85.04 timer the circuit is limited to 7 A
- Fits only the specified relay series
- Socket current is also limited by the relay ratings – the lower value applies
Safety and installation notes
- Install and replace relays only with the supply disconnected.
- Tighten wires to the recommended torque; do not exceed the terminal cross-section.
- Use only compatible relays and retaining clips.
- Protect the socket circuit with a circuit breaker or fuse.
Quick selection guide
55.32 / 55.3410 A / 250 VIP20094.91.3Suitable when you need:- to mount a plug-in relay on DIN rail
- to replace relays without disconnecting wires
- to assemble an automation panel neatly
Check before use:- that the relay series fits this socket
- wire cross-section and terminal type
- space in the panel (width, height under the cover)
Important reminder: a socket is not a protective device – the circuit must be protected by a circuit breaker or fuse.FAQ
Which relays fit?
This socket is designed for Finder 55.32 / 55.34 relays.Is the relay included?
No, the relay is sold separately.How is it mounted?
It snaps onto a 35 mm DIN rail.Can the relay be replaced without disconnecting wires?
Yes, that is the main advantage of a socket.Does the socket protect the circuit?
No, the circuit must be protected by a circuit breaker or fuse.Do you help with selection?
Yes, send us the relay code – we will select a suitable socket and accessories.Relay socket | Finder 55.32 / 55.34 | 10 A | 250 V | DIN 35 mm | Finder 94.04SPA
Finder 94.04SPA – socket for Finder 55.32 / 55.34 relays, DIN rail mounting, with screw terminals for fast relay replacement in automation panels.
Published: 2026-11-05 · Data verified against the manufacturer datasheet: 2026-11-05
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Interface relay | 2CO | 8 A | coil 24 V DC | plug-in | Schneider Electric RSB2A080BDCode: RSB 2A080BDSchneider Electric RSB2A080BD – interface relay with 2CO contacts (8 A) and 24 V DC coil. For control signal isolation, contact multiplication and control of contactor and valve coils in automation panels.
Price 2.94 € VAT incl.( 2.43 € VAT excl. )