Products catalog

  • Power switch-disconnector with handle | 3P | 100A | AC420/690V | 50/60Hz | for installation in an electrical panel

    Code: ES-EADS-2

    Power switch-disconnector designed for switching on, switching off and safely disconnecting three-phase electrical circuits from the power source. This device is used in industrial electrical panels, distribution cabinets, equipment control systems and other applications where reliable manual circuit disconnection is required.

    With a rated current of 100A and a rated voltage of AC420/690V, this load isolating switch is suitable for various three-phase electrical systems where clearly visible, mechanical and reliable contact switching is important. The switch-disconnector type construction allows the load to be quickly disconnected during maintenance, repair or emergency situations. 

  • Technical Specifications

    Product type: Load break switch with handle
    Number of poles: 3P
    Rated current: 100A
    Rated voltage: AC420/690V
    Frequency: 50Hz / 60Hz
    Application area: industry, electrical distribution systems, control cabinets
    Purpose: load disconnection, circuit isolation, manual switching
    Installation: inside an electrical panel / cabinet
    Material: PC plastic
    Application: for three-phase AC circuits
    Control: manual mechanical control
    Working environment: electrical panels, distribution boxes, industrial control cabinets

    Functions

    Disconnection of a three-phase circuit – disconnects 3 phases simultaneously in a three-phase electrical system
    Load isolation – allows the electrical circuit to be safely separated from the power supply during maintenance or repair
    Manual switching on and off – the switch is operated mechanically, allowing clear control of the circuit status
    Use in electrical panels – designed for installation in electrical distribution or control cabinets
    Main disconnector function – can be used as the main manual disconnection point for a specific circuit or device
    Increased service safety – helps reduce risks during electrical equipment maintenance
    Power control of industrial equipment – suitable for disconnecting three-phase motors, equipment, lines or distribution circuits
    Clear contact position – the knife-switch construction makes it easier to understand whether the circuit is switched on or disconnected
    Operation in 50/60Hz networks – can be used in different alternating current networks
    Suitable for AC420/690V systems – designed for three-phase industrial alternating current circuits

    Use

    For household users: Can be relevant in garages, workshops or utility buildings where three-phase equipment is used and manual circuit disconnection is required.
    For electricians: Suitable for installing electrical panels where a clear 3-phase load disconnection point is required.
    For engineers / designers: Can be included in electrical distribution diagrams as a manual load isolation switch.
    For industrial companies: Used for disconnecting production lines, three-phase equipment, motors or electrical distribution circuits.
    For maintenance specialists: Helps safely disconnect equipment before repair, inspection or service work.

    Advantages

    100A rated current – suitable for higher-power three-phase circuits
    3P construction – all three phases are disconnected simultaneously
    Suitable for AC420/690V systems – can be used in industrial three-phase systems
    Clear mechanical control – easy to understand the switch status
    Suitable for installation in electrical panels – designed for distribution and control cabinets
    Convenient for maintenance – allows safe circuit disconnection during service work
    Universal application – can be used in industry, commercial facilities, workshops and technical rooms

    Disadvantages

    No automatic protection function – this is not an automatic circuit breaker with short-circuit or overload protection
    Manual control – no remote or automatic switching function

    Is this switch suitable for a three-phase system?

    Yes. The switch is 3P, therefore it is designed for three-phase electrical circuits where three phases need to be disconnected simultaneously.

    Can it be used as the main disconnector of an electrical panel?

    Yes, it can be used as the main manual disconnector, but the specific electrical installation diagram, load, protection devices and applicable requirements must be assessed.

    Does this switch protect against overload?

    No, the switch does not replace a circuit breaker or fuses. Dedicated protection devices must be used for overload and short-circuit protection.

    Where is this switch installed?

    It is installed inside an electrical panel, distribution cabinet or control cabinet for disconnecting a three-phase circuit. 

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information