LC1K contactor | 3P | 6A | 115VAC coil | 3NO auxiliary contacts | for electric motors and control circuits
Code: LC1K0610FE7Contactor designed for switching on and off electric motors, lighting, heating, ventilation, automation systems, and other electrical circuits. The contactor has 3 poles, a rated current of 6A, a 115VAC control coil, and 3 normally open power contacts.-
LC1K Contactor – 3P, 6A, 115VAC Coil, 3NO Power Contacts, for Electric Motors and Control Circuits
The LC1K Contactor 3P 6A 115VAC 3NO is a compact electromagnetic contactor designed for switching electric motors, lighting, heating, ventilation, automation, and other electrical circuits on and off. The contactor features 3 poles, a 6A rated current, a 115VAC control coil, and 3 normally open power contacts.
Main Idea:
This LC1K-type contactor is intended for compact and reliable electrical circuit control when remote switching of three-phase loads is required. The 115VAC coil allows the contactor to be operated from an appropriate control circuit, and the 3NO contact configuration is suitable for typical three-phase load switching.Type
Electromagnetic ContactorNumber of Poles
3PControl Coil
115VACContacts
3NOOperating Principle
The contactor operates on an electromagnetic principle. When voltage is applied to the 115VAC control coil, the coil creates a magnetic field that attracts the contactor mechanism and closes the main power contacts. This turns on the connected load – for example, an electric motor, fan, pump, or other electrical equipment.
When the control voltage is disconnected from the coil, the magnetic field vanishes, the contactor mechanism returns to its original position, and the main contacts open. This allows for safe and convenient control of loads via buttons, relays, controllers, automation systems, or safety devices.
What are the benefits of the LC1K contactor?
The LC1K contactor is a compact solution for control panels and automation systems when reliable switching of low-power three-phase loads is required. It is frequently used in conjunction with control buttons, thermal relays, timers, relay controllers, or PLC systems.Technical Parameters
Series / Type LC1K Product Type Electromagnetic Contactor Number of Poles 3P Rated Current 6A Control Coil Voltage 115VAC Main Contact Configuration 3NO – 3 Normally Open Contacts Purpose Control of motors, fans, pumps, lighting, heating, and automation circuits Control Type Electromagnetic Usage Control panels, automation systems, equipment control circuits Mounting Location Electrical cabinet, control panel, automation box Circuit Type Power and control circuits Compatibility With appropriate control circuits, safety devices, and additional accessories per specific diagram Where is it used?
- Motor control – for low-power motors, pumps, fans, or actuators.
- Automation panels – as an actuator controlled by a relay, controller, or pushbuttons.
- Lighting circuits – when lighting groups need to be switched on or off via a control circuit.
- Heating and ventilation systems – for controlling fans, heating elements, or other equipment based on an automation signal.
- Industrial equipment – for switching technological components, auxiliary mechanisms, and control circuits.
Practical Installation Example
For instance, the contactor is installed in a control panel and used to start a small three-phase motor. The control circuit may include START/STOP buttons, a protective thermal relay, or an automation controller. Upon pressing the START button or receiving a control signal, 115VAC voltage is applied to the coil, the contactor engages, and starts the motor.
When the control signal is lost, protection triggers, or the STOP button is pressed, the contactor disengages and disconnects the load from the power circuit.
Usage by Need
For Electricians: A convenient choice when assembling control panels, motor starting circuits, automation nodes, or control circuits for low-power loads.
For Automation Specialists: The contactor can be used as an actuator controlled by a relay, timer, programmable controller, or other automation equipment.
For Engineers/Designers: A suitable component when designing systems requiring three-pole power circuit switching and 115VAC control voltage.
For Maintenance Specialists: Can be used when replacing or upgrading existing contactors, provided the coil voltage, contact configuration, current, and mounting requirements match.
Pros
- Compact LC1K type contactor – convenient for installation in control panels.
- 3P construction – suitable for switching three-phase loads.
- 3NO contacts – most commonly used contactor configuration for motor and load control.
- 115VAC coil – suitable for systems using this specific control voltage.
- 6A rated current – suitable for low-power loads.
- Compatible with automation systems – control via relays, controllers, buttons, or timers.
- Clear operating principle – easy for diagnostics and maintenance.
Cons / Limitations
- 6A current – not suitable for high-power loads without additional assessment.
- 115VAC coil – will not work in systems with 24VDC, 230VAC, or other control voltages.
- Check load category – permissible currents may differ for motors, lighting, and other loads.
- Proper protection required – the contactor does not replace an automatic circuit breaker, fuse, or thermal protection.
- Not for direct use without an enclosure – must be installed in a suitable electrical equipment environment.
Safety and Installation Notes
The contactor is an electrical circuit control device; therefore, before installation, it is essential to assess the load type, rated current, coil voltage, contact configuration, protection devices, and the specific control circuit.
- Installation must be performed by a qualified electrician in accordance with electrical safety regulations.
- Ensure power is disconnected before working and verify the circuit is de-energized.
- Coil voltage must match the control circuit – this contactor requires 115VAC control voltage.
- Do not exceed rated parameters – the load must match the contactor's permissible current and utilization category.
- Use protection in motor circuits – such as a circuit breaker, fuses, and a thermal relay if necessary.
- Verify circuit compatibility with the specific motor, equipment, controller, or automation system.
Quick Selection Guide
The LC1K 3P 6A 115VAC 3NO contactor is suitable when a compact contactor is needed to control low-power three-phase loads in a system utilizing 115VAC control voltage. It can be used in control systems for motors, fans, pumps, lighting, or other equipment.
Poles
3PCurrent
6ACoil
115VACContacts
3NOSuitable when you need:- a compact 3-pole contactor;
- 6A current load control;
- a 115VAC control coil;
- a 3NO contact configuration;
- a solution for a control panel, automation, or low-power motor control.
Check before purchasing:- whether your control circuit is indeed 115VAC;
- whether 6A current is sufficient for your specific load;
- whether additional auxiliary contacts are required;
- whether a thermal relay is needed for motor protection;
- whether the 3NO contact configuration matches your circuit diagram.
Important Reminder:
The contactor is only a load switching device. It does not replace short-circuit, overload, or residual current protection. Appropriate protection devices must be used in the electrical circuit according to the load and installation conditions.FAQ – Frequently Asked Questions
What is the LC1K contactor for?
It is used for switching electrical circuits on and off via a control signal. It is most commonly used in motor, fan, pump, lighting, or automation circuits.What does 3P mean?
3P means the contactor has 3 main poles, allowing it to switch a three-phase electrical circuit.What does 3NO mean?
3NO means 3 normally open contacts. They close when the contactor coil receives control voltage.Is this contactor suitable for a 230VAC control circuit?
No, if the coil is specified as 115VAC, it must be operated with 115VAC voltage. For 230VAC control, a contactor with a 230VAC coil is required.Does the contactor protect the motor from overload?
No. The contactor only switches the load on and off. A thermal relay or another appropriate protection device is typically used for motor overload protection.Can it be used in an automation system?
Yes, the contactor can be controlled via relays, timers, controllers, or other automation elements, provided their output is compatible with 115VAC coil control.Compact Contactor for Control Panels, Automation, and Low-Power Loads
The LC1K 3P 6A 115VAC 3NO contactor is a practical solution when reliable switching of three-phase loads via a 115VAC control circuit is required. It is suitable for controlling motors, fans, pumps, lighting, and other electrical equipment.
Due to its 3-pole design, 3NO contacts, 6A rated current, and compact LC1K format, this contactor can be used in control panels, automation systems, and maintenance tasks where a clear, reliable, and easily integrated electrical circuit control component is required.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Marker cable ties | 2.5x110 mm | white | nylon PA66 | 100 pcs | 4772124000407Code: 4772124000407Price 2.42 € VAT incl.( 2.00 € VAT excl. )Terminal | connector paste for contacts | reduces oxidation | 35.3g | WAGO | ALU PLUS | 249-130 | for connecting aluminium and copper wiresCode: 4017332133890Price 2.83 € VAT incl.( 2.34 € VAT excl. )