Products catalog

  • LC1K mini contactor | 3P | 16A | 7.5kW | 24VAC coil | 1NO auxiliary contact | for electric motor and control circuits

    Code: LC1K1610B7
    Mini contactor designed for controlling electric motors, fans, pumps, lighting, heating and automation circuits. The contactor has 3 poles, a rated current of 16A, power of 7.5kW, a 24VAC control coil and 1 normally open auxiliary contact. Due to its compact size, it is convenient to use in control cabinets, smaller automation panels and equipment control circuits. 
  • LC1K mini contactor 3P 16A – 7.5kW, 24VAC coil, 1NO auxiliary contact

    Mini contactor designed for the control of electric motors, fans, pumps, lighting, heating, and automation circuits. The contactor features 3 poles, 16A rated current, 7.5kW power, 24VAC control coil, and 1 normally open (NO) auxiliary contact. Due to its compact size, it is convenient for use in control cabinets, smaller automation panels, and equipment control circuits.

    Main idea:
    This mini contactor is designed for switching three-phase electrical circuits on and off when a compact, reliable, and easy-to-install solution is required in a control cabinet. The 24VAC coil allows the contactor to be controlled by standard control voltage, while the 1NO auxiliary contact can be used for signaling, interlocking, or automation circuit logic.
    Number of poles
    3P
    Rated current
    16 A
    Control coil
    24VAC
    Power
    7.5 kW

    Operating principle

    The contactor operates on an electromagnetic principle. When voltage is applied to the 24VAC control coil, the coil generates a magnetic field that pulls in the contactor mechanism and closes the main power contacts. This switches on the connected load – for example, an electric motor, fan, pump, or other electrical circuit.

    When the control voltage is removed from the coil, the contactor mechanism returns to its original position, and the power contacts open. The additional 1NO contact can be used for contactor status indication, interlocking of automation circuits, signal control, or auxiliary logic within the control scheme.

    What is the benefit of the LC1K mini contactor?
    The LC1K series mini contactor is a compact solution for when space is limited in a control cabinet but reliable control of a three-phase load is needed. It is suitable for small to medium power motors, automation assemblies, ventilation, lighting, or auxiliary control systems.

    Technical parameters

    Product type Mini contactor
    Product code LC1K1610B7
    Series / model LC1K
    Number of poles 3P
    Rated current 16 A
    Power 7.5 kW
    Control coil voltage 24VAC
    Main power contacts 3 main contacts for three-phase circuit
    Auxiliary contact 1NO – 1 normally open contact
    Contactor application Control of electric motors, lighting, heating, ventilation, and automation circuits
    Mounting location Electrical panels, control cabinets, automation boxes, and equipment control systems
    Design Compact mini contactor housing
    Weight 0.179 kg

    Where is it used?

    • Electric motor control – switching small to medium power three-phase motors on and off.
    • Ventilation systems – control of fans, air supply, or extraction equipment.
    • Pump control circuits – switching on water, circulation, or process pumps.
    • Lighting and heating systems – when the load needs to be controlled via an automation signal.
    • Automation and control cabinets – as a compact actuator element in circuits controlled by PLCs, relays, or switches.

    Practical installation example

    For example, the contactor is mounted in a control cabinet and used to control a three-phase fan or pump. A control button, relay, timer, pressure switch, or automation controller provides a 24VAC signal to the contactor coil, and the contactor switches on the main power circuit.

    The 1NO auxiliary contact can be used for an indicator light, working status signal, interlocking circuit, or for a controller input so that the system can see when the contactor is energized.

    Usage according to needs

    For an electrician: A convenient contactor for installation in electrical panels, automation boxes, and equipment control circuits. The compact housing allows for space saving in the control cabinet.

    For an engineer/designer: A suitable choice when designing low-power motor, ventilation, heating, lighting, or automation control circuits that require a 3P contactor with a 24VAC control coil.

    For maintenance personnel: Can be used as a replaceable control element in devices requiring a compact three-phase load contactor with an auxiliary contact for signaling or interlocking.

    Pros

    • Compact mini contactor size – convenient for installation in limited space.
    • 3P power contacts – suitable for controlling three-phase circuits.
    • 16A rated current – suitable for many small-power control tasks.
    • 7.5kW power – practical solution for electric motor control.
    • 1NO auxiliary contact – can be used for signaling, indication, or interlocking.
    • Low weight (0.179 kg) – convenient for assembly and installation in panels.
    • Suitable for automation systems – can be controlled via buttons, relay contacts, or controllers.

    Cons / limitations

    • Not suitable for large loads – essential not to exceed 16A and 7.5kW parameters.
    • Does not protect the motor itself – additional protection, such as a motor circuit breaker or thermal overload relay, is required to protect the motor.
    • Requires a proper circuit design – essential to evaluate load type, inrush currents, control voltage, and protection.
    • Must be installed in an electrical panel or a suitable protective enclosure depending on environmental conditions.

    Safety and installation notes

    The contactor is an electrical control device; therefore, before installation, it is essential to evaluate load current, control voltage, motor power, protective devices, wire cross-section, and the installation environment.

    • Installation must be performed by a qualified electrician in accordance with electrical safety requirements.
    • Before installation, disconnect power and ensure the circuit is de-energized.
    • Do not exceed rated current and power – the load must match the contactor specifications.
    • Control coil voltage must be 24VAC – improper coil voltage can damage the contactor.
    • Motor overload and short-circuit protection is recommended.
    • The contactor must be installed in a suitable electrical panel or enclosure matching the environmental conditions.

    Quick selection guide

    This mini contactor is suitable when you need a compact 3-pole contactor with 16A current, 7.5kW power, 24VAC control coil, and 1NO auxiliary contact. It is a practical solution for automation cabinets, motor control, ventilation, pumps, lighting, or heating circuits.

    Code
    LC1K1610B7
    Contacts
    3P + 1NO
    Coil
    24VAC
    Current / Power
    16A / 7.5kW
    Suitable when you need:
    • a compact mini contactor for a control cabinet;
    • a 3-pole contactor for a three-phase circuit;
    • a 24VAC control coil;
    • a 16A and 7.5kW contactor;
    • a 1NO auxiliary contact for indication or interlocking.
    Check before purchasing:
    • if a 24VAC coil is required;
    • if the load current does not exceed 16A;
    • if 7.5kW power meets your motor or equipment requirements;
    • if a 1NO auxiliary contact is needed;
    • if the control scheme is compatible with this contactor.
    Important reminder:
    The contactor is just a control element. It does not replace a circuit breaker, fuse, or motor protection device. In the final circuit, it is essential to provide proper protection against short-circuit, overload, and other faults.

    FAQ – Frequently asked questions

    What is this mini contactor for?
    It is designed for switching electric motors, pumps, fans, lighting, heating, and automation circuits on and off.
    What is the control coil voltage?
    The coil voltage for this contactor is 24VAC. Before installation, ensure that your control circuit uses this specific voltage.
    Is the contactor suitable for a three-phase motor?
    Yes, the contactor has 3 poles and can be used for three-phase circuits, provided the motor power, current, starting conditions, and protection are within limits.
    What does 1NO mean?
    1NO stands for one normally open auxiliary contact. It can be used for indication, signaling, interlocking, or automation control logic.
    Does the contactor protect the motor from overload?
    No. The contactor only switches the circuit on and off. For motor protection, a separate motor protection device, thermal overload relay, or circuit breaker must be used.
    Where is this contactor mounted?
    It is usually mounted in electrical panels, control cabinets, automation boxes, or equipment control systems.

    Compact 3P mini contactor for motor and automation circuits

    The mini contactor is a practical choice when you need a compact 3-pole contactor with 16A rated current, 7.5kW power, 24VAC control coil, and 1NO auxiliary contact.

    Due to its small size, easy installation, and wide range of applications, this contactor is suitable for control cabinets, automation systems, ventilation, pumps, lighting, heating, and electric motor control circuits where reliable switching is essential.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals

    privacy policy

    Information