LC1K mini contactor | 3P | 16A | 7.5kW | 24VAC coil | 1NO auxiliary contact | for electric motor and control circuits
Code: LC1K1610B7Mini contactor designed for controlling electric motors, fans, pumps, lighting, heating and automation circuits. The contactor has 3 poles, a rated current of 16A, power of 7.5kW, a 24VAC control coil and 1 normally open auxiliary contact. Due to its compact size, it is convenient to use in control cabinets, smaller automation panels and equipment control circuits.-
LC1K mini contactor 3P 16A – 7.5kW, 24VAC coil, 1NO auxiliary contact
Mini contactor designed for the control of electric motors, fans, pumps, lighting, heating, and automation circuits. The contactor features 3 poles, 16A rated current, 7.5kW power, 24VAC control coil, and 1 normally open (NO) auxiliary contact. Due to its compact size, it is convenient for use in control cabinets, smaller automation panels, and equipment control circuits.
Main idea:
This mini contactor is designed for switching three-phase electrical circuits on and off when a compact, reliable, and easy-to-install solution is required in a control cabinet. The 24VAC coil allows the contactor to be controlled by standard control voltage, while the 1NO auxiliary contact can be used for signaling, interlocking, or automation circuit logic.Number of poles
3PRated current
16 AControl coil
24VACPower
7.5 kWOperating principle
The contactor operates on an electromagnetic principle. When voltage is applied to the 24VAC control coil, the coil generates a magnetic field that pulls in the contactor mechanism and closes the main power contacts. This switches on the connected load – for example, an electric motor, fan, pump, or other electrical circuit.
When the control voltage is removed from the coil, the contactor mechanism returns to its original position, and the power contacts open. The additional 1NO contact can be used for contactor status indication, interlocking of automation circuits, signal control, or auxiliary logic within the control scheme.
What is the benefit of the LC1K mini contactor?
The LC1K series mini contactor is a compact solution for when space is limited in a control cabinet but reliable control of a three-phase load is needed. It is suitable for small to medium power motors, automation assemblies, ventilation, lighting, or auxiliary control systems.Technical parameters
Product type Mini contactor Product code LC1K1610B7 Series / model LC1K Number of poles 3P Rated current 16 A Power 7.5 kW Control coil voltage 24VAC Main power contacts 3 main contacts for three-phase circuit Auxiliary contact 1NO – 1 normally open contact Contactor application Control of electric motors, lighting, heating, ventilation, and automation circuits Mounting location Electrical panels, control cabinets, automation boxes, and equipment control systems Design Compact mini contactor housing Weight 0.179 kg Where is it used?
- Electric motor control – switching small to medium power three-phase motors on and off.
- Ventilation systems – control of fans, air supply, or extraction equipment.
- Pump control circuits – switching on water, circulation, or process pumps.
- Lighting and heating systems – when the load needs to be controlled via an automation signal.
- Automation and control cabinets – as a compact actuator element in circuits controlled by PLCs, relays, or switches.
Practical installation example
For example, the contactor is mounted in a control cabinet and used to control a three-phase fan or pump. A control button, relay, timer, pressure switch, or automation controller provides a 24VAC signal to the contactor coil, and the contactor switches on the main power circuit.
The 1NO auxiliary contact can be used for an indicator light, working status signal, interlocking circuit, or for a controller input so that the system can see when the contactor is energized.
Usage according to needs
For an electrician: A convenient contactor for installation in electrical panels, automation boxes, and equipment control circuits. The compact housing allows for space saving in the control cabinet.
For an engineer/designer: A suitable choice when designing low-power motor, ventilation, heating, lighting, or automation control circuits that require a 3P contactor with a 24VAC control coil.
For maintenance personnel: Can be used as a replaceable control element in devices requiring a compact three-phase load contactor with an auxiliary contact for signaling or interlocking.
Pros
- Compact mini contactor size – convenient for installation in limited space.
- 3P power contacts – suitable for controlling three-phase circuits.
- 16A rated current – suitable for many small-power control tasks.
- 7.5kW power – practical solution for electric motor control.
- 1NO auxiliary contact – can be used for signaling, indication, or interlocking.
- Low weight (0.179 kg) – convenient for assembly and installation in panels.
- Suitable for automation systems – can be controlled via buttons, relay contacts, or controllers.
Cons / limitations
- Not suitable for large loads – essential not to exceed 16A and 7.5kW parameters.
- Does not protect the motor itself – additional protection, such as a motor circuit breaker or thermal overload relay, is required to protect the motor.
- Requires a proper circuit design – essential to evaluate load type, inrush currents, control voltage, and protection.
- Must be installed in an electrical panel or a suitable protective enclosure depending on environmental conditions.
Safety and installation notes
The contactor is an electrical control device; therefore, before installation, it is essential to evaluate load current, control voltage, motor power, protective devices, wire cross-section, and the installation environment.
- Installation must be performed by a qualified electrician in accordance with electrical safety requirements.
- Before installation, disconnect power and ensure the circuit is de-energized.
- Do not exceed rated current and power – the load must match the contactor specifications.
- Control coil voltage must be 24VAC – improper coil voltage can damage the contactor.
- Motor overload and short-circuit protection is recommended.
- The contactor must be installed in a suitable electrical panel or enclosure matching the environmental conditions.
Quick selection guide
This mini contactor is suitable when you need a compact 3-pole contactor with 16A current, 7.5kW power, 24VAC control coil, and 1NO auxiliary contact. It is a practical solution for automation cabinets, motor control, ventilation, pumps, lighting, or heating circuits.
Code
LC1K1610B7Contacts
3P + 1NOCoil
24VACCurrent / Power
16A / 7.5kWSuitable when you need:- a compact mini contactor for a control cabinet;
- a 3-pole contactor for a three-phase circuit;
- a 24VAC control coil;
- a 16A and 7.5kW contactor;
- a 1NO auxiliary contact for indication or interlocking.
Check before purchasing:- if a 24VAC coil is required;
- if the load current does not exceed 16A;
- if 7.5kW power meets your motor or equipment requirements;
- if a 1NO auxiliary contact is needed;
- if the control scheme is compatible with this contactor.
Important reminder:
The contactor is just a control element. It does not replace a circuit breaker, fuse, or motor protection device. In the final circuit, it is essential to provide proper protection against short-circuit, overload, and other faults.FAQ – Frequently asked questions
What is this mini contactor for?
It is designed for switching electric motors, pumps, fans, lighting, heating, and automation circuits on and off.What is the control coil voltage?
The coil voltage for this contactor is 24VAC. Before installation, ensure that your control circuit uses this specific voltage.Is the contactor suitable for a three-phase motor?
Yes, the contactor has 3 poles and can be used for three-phase circuits, provided the motor power, current, starting conditions, and protection are within limits.What does 1NO mean?
1NO stands for one normally open auxiliary contact. It can be used for indication, signaling, interlocking, or automation control logic.Does the contactor protect the motor from overload?
No. The contactor only switches the circuit on and off. For motor protection, a separate motor protection device, thermal overload relay, or circuit breaker must be used.Where is this contactor mounted?
It is usually mounted in electrical panels, control cabinets, automation boxes, or equipment control systems.Compact 3P mini contactor for motor and automation circuits
The mini contactor is a practical choice when you need a compact 3-pole contactor with 16A rated current, 7.5kW power, 24VAC control coil, and 1NO auxiliary contact.
Due to its small size, easy installation, and wide range of applications, this contactor is suitable for control cabinets, automation systems, ventilation, pumps, lighting, heating, and electric motor control circuits where reliable switching is essential.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Terminal | connector paste for contacts | reduces oxidation | 35.3g | WAGO | ALU PLUS | 249-130 | for connecting aluminium and copper wiresCode: 4017332133890Price 2.83 € VAT incl.( 2.34 € VAT excl. )Marker cable ties | 2.5x110 mm | white | nylon PA66 | 100 pcs | 4772124000407Code: 4772124000407Price 2.42 € VAT incl.( 2.00 € VAT excl. )