Products catalog

  • LC2K reversing contactor | 3P | 6A | 230VAC coil | 3NO auxiliary contacts | for electric motors and control circuits

    Code: LC2K0601P7
    Compact Schneider Electric TeSys K series reversing contactor designed to change the direction of rotation of three-phase electric motors. The device consists of two contactors with mechanical interlocking and factory-configured reversing wiring, enabling safe forward and reverse motor control. The contactor has 3 poles, a 6 A AC-3 rated current, and a 230 V AC 50/60 Hz control coil. 
  • Reversing Contactor – 3P, 6A, AC-3, 230VAC Coil, 3NO Auxiliary Contacts

    A compact Schneider Electric TeSys K series reversing contactor, designed for changing the rotation direction of three-phase electric motors. The device consists of two contactors with mechanical interlocking and factory-pre-wired reversing connections, helping to safely control motor rotation in both forward and reverse directions. The contactor features 3 poles, 6 A AC-3 rated current, and a 230 V AC 50/60 Hz control coil.

    Core Concept:
    A reversing contactor is used when it is necessary to electrically change the rotation direction of a three-phase motor. It is designed for controlling smaller motors, such as those in conveyors, gate mechanisms, lifting equipment, fans, machine tools, or other devices that require forward and reverse operation.
    Main Poles
    3P / 3NO
    Rated Current
    6 A, AC-3
    Control Coil
    230 VAC, 50/60 Hz
    Application
    Reversing Motor Direction

    Operating Principle

    A reversing contactor works by swapping the phases of a three-phase motor. When one part of the contactor is energized, the motor rotates in one direction; when the other part is energized, the phase sequence is changed, and the motor rotates in the opposite direction.

    The included mechanical interlock prevents both contactors from being energized simultaneously. This helps prevent short circuits and protects the motor and electrical installation from incorrect switching.

    Why use a reversing contactor?
    A standard contactor only switches a motor on or off, whereas a reversing contactor additionally allows for changing the motor's rotation direction. This is essential for mechanisms that need to move forward and backward, lift and lower, open and close, or change transportation direction.

    Technical Parameters

    Manufacturer Schneider Electric
    Series TeSys K
    Model / Code LC2K0601P7
    Product Type Reversing Contactor
    Number of Poles 3P
    Main Contact Configuration 3NO / 3 Normally Open Contacts
    Rated Operational Current 6 A, AC-3 Category
    Operating Voltage AC-3 Mode Up to 440 VAC
    Nominal Motor Power at 400 VAC, AC-3 Up to 2.2 kW
    Nominal Motor Power at 230 VAC, AC-3 Up to 1.5 kW
    Control Coil Voltage 230 VAC
    Control Coil Frequency 50/60 Hz
    Mechanical Interlocking Yes
    Reversing Power Connections Factory Pre-wired
    Terminal Type Screw Clamps
    Mounting DIN Rail or Mounting Plate
    Protection Class IP20
    Operating Temperature -25°C ... +50°C
    Approximate Dimensions 90 x 58 x 57 mm
    Weight 0.361 kg

    Where is it used?

    • Conveyors – for changing transport direction.
    • Gates and Barriers – for opening and closing functions.
    • Lifting Mechanisms – for controlling upward and downward movement.
    • Ventilation and Air Supply Systems – when motor direction reversal is required.
    • Machine Tools and Workshops – for reversing smaller three-phase motors.
    • Automation Panels – for motor control schemes and technological lines.

    Practical Installation Example

    For example, a reversing contactor can be used in automatic gate systems or a small conveyor control panel. One control signal switches the motor to run forward, and another signal switches it to run in reverse.

    The mechanical interlock ensures that the forward and reverse contactors will not be activated at the same time. Additionally, the control scheme usually employs electrical interlocking contacts, motor protection, control buttons, emergency stop circuits, and other safety elements.

    Professional Use

    Electrician: A convenient solution for smaller motor reversing control schemes. Factory-pre-wired connections and mechanical interlocking help assemble and organize the equipment in the electrical cabinet more efficiently.

    Automation Engineer: A suitable component for drive control systems that require forward/reverse functionality. The contactor can be used in conjunction with pushbuttons, switches, PLC controllers, timer relays, limit switches, and motor protection devices.

    Maintenance Specialist: Suitable for replacing an existing reversing contactor or modernizing a small-power motor control system, provided the coil voltage, motor power, contact load, and control scheme compatibility have been verified.

    Pros

    • Reversing Operation – allows changing the rotation direction of a three-phase motor.
    • 3P and 6A AC-3 – suitable for controlling smaller three-phase motors.
    • 230 VAC Control Coil – convenient for standard 230V control circuits.
    • Mechanical Interlocking – helps prevent simultaneous engagement of both directions.
    • Factory Pre-wired – fewer cables and simpler panel assembly.
    • Compact Dimensions – an ideal solution for smaller electrical cabinets.
    • DIN Rail or Plate Mounting – flexible installation options.
    • Schneider Electric TeSys K Series – a well-known industrial automation brand.

    Cons / Limitations

    • 6 A Rated Current – not suitable for high-power motors.
    • IP20 Protection Class – must be installed in a protected electrical cabinet or enclosure.
    • 230 VAC Coil – not suitable for 24V, 48V, or other control voltages without additional solutions.
    • Proper Control Scheme Required – mechanical interlocking alone is not enough for total motor protection.
    • Motor Protection Necessary – it is recommended to use properly selected thermal or electronic motor protection.

    Safety and Installation Notes

    The reversing contactor is used in three-phase motor control circuits; therefore, incorrect wiring can lead to equipment failure, short circuits, or hazards to personnel. Installation and connection should only be performed by a qualified electrician.

    • Disconnect power before installation and ensure there is no voltage in the circuit.
    • Check the control coil voltage – this model requires 230 VAC.
    • Do not exceed 6 A AC-3 rated current and consider actual motor power and inrush currents.
    • Use appropriate motor protection against overloads and short circuits.
    • Install the IP20 contactor in a closed cabinet, protected from dust, moisture, and accidental contact.
    • Use electrical interlocking in the reversing scheme, proper logic for control signals, and time delays between direction changes if necessary.

    Quick Selection Guide

    This is a suitable choice when a reversing contactor is needed for a smaller three-phase motor using a 230 VAC control circuit. This model is ideal for motors up to 2.2 kW at 400 VAC AC-3 operation when direction reversal is required.

    Motor Control
    Forward / Reverse
    AC-3 Current
    6 A
    Coil
    230 VAC
    Motor Power at 400 V
    Up to 2.2 kW
    Suitable when you need:
    • to change the direction of a small three-phase motor;
    • forward and reverse motor control;
    • a compact reversing contactor for an electrical panel;
    • a 230 VAC control coil;
    • mechanical interlocking and factory-pre-wired connections.
    Check before ordering:
    • if your motor's rated current does not exceed 6 A AC-3;
    • if the motor power does not exceed 2.2 kW at 400 VAC;
    • if the control circuit uses 230 VAC;
    • if additional auxiliary contacts, thermal relays, or motor protection are needed;
    • if there is enough space in the electrical cabinet for the contactor and additional components.
    Important Reminder:
    A reversing contactor is not a complete motor protection system. To safely operate the motor, it is mandatory to provide appropriate protection against overloads, short circuits, emergency stop functionality, and a correct electrical interlocking scheme.

    FAQ – Frequently Asked Questions

    What is this reversing contactor for?
    It is designed to change the rotation direction of three-phase motors. It can control motor operation in both forward and reverse directions.
    What is the control coil voltage?
    This model uses a 230 VAC, 50/60 Hz control coil.
    What power motor is it suitable for?
    At 400 VAC and AC-3 duty, the contactor is suitable for motors up to 2.2 kW, but final selection should always be based on the actual motor rated current, duty cycle, and starting conditions.
    Can it be mounted on a DIN rail?
    Yes, the contactor can be mounted on a DIN rail or a mounting plate in an electrical cabinet.
    Does it have protection against simultaneous activation?
    Yes, the design uses mechanical interlocking, which prevents both contactors in the reversing pair from being energized at the same time. However, electrical interlocking is also recommended in the control scheme.
    Is this a complete motor protection system?
    No. The contactor is intended for switching the motor on, off, and changing direction. For protection against overload and short circuits, you must additionally use properly selected protection devices.

    A Compact Reversing Contactor for Reliable Control of Small Three-Phase Motors

    This is an essential solution for changing motor direction in automatic gates, conveyors, ventilation units, lifting mechanisms, machine tools, and other systems.

    With a 3-pole design, 6 A AC-3 rated current, 230 VAC coil, mechanical interlock, factory-pre-wired reversing connections, and DIN rail mounting capability, this contactor is easy to integrate into professional motor control schemes.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals

    privacy policy

    Information