Products catalog

  • LC2K Reversing Mini Contactor | 3P | 16A | 7.5kW | 230VAC Coil | 1NO Auxiliary Contact | For Electric Motors and Control Circuits

    Code: LC2K1610P7
    Reversing mini contactor designed for changing the rotation direction of three-phase electric motors, as well as for control and automation circuits. The device consists of two interconnected contactors that allow the motor phases to be safely switched, enabling forward or reverse motor rotation. The contactor has 3 poles, a rated current of 16 A, a power rating of 7.5 kW, a 230 VAC control coil, and 1 normally open auxiliary contact. 
  • LC2K Reversing Mini Contactor – 3P, 16A, 7.5kW, 230VAC Coil, 1NO Auxiliary Contact

    Reversing mini contactor, designed to change the rotation direction of three-phase electric motors, for control and automation circuits. The device consists of two interconnected contactors that allow for safely switching the motor phases and selecting forward or reverse motor rotation. The contactor features 3 poles, 16A rated current, 7.5kW power, a 230VAC control coil, and 1 normally open auxiliary contact.

    Main Idea:
    A reversing contactor is used when it is necessary not only to turn a three-phase motor on or off but also to change its direction of rotation. It is suitable for conveyors, gates, lifting mechanisms, fans, pumps, machine tools, and other automation systems where motor operation in both forward and reverse directions is required.
    Number of Poles
    3P
    Rated Current
    16A
    Motor Power
    7.5kW
    Control Coil
    230VAC

    Operating Principle

    A reversing contactor consists of two contactors: one designed for operating the motor in one direction, and the other for the opposite direction. By changing the phase sequence, the rotation direction of the three-phase electric motor is changed.

    The contactors in a reversing system must be controlled so that both are not switched on at the same time. Therefore, mechanical and/or electrical interlocking is used in reversing contactors, which helps prevent short circuits between phases and protects the motor control circuit.

    When is a reversing contactor needed?
    It is needed when the motor must operate in both directions: for example, to raise and lower a mechanism, open and close gates, change the moving direction of a conveyor, or control a reversible fan or machine tool mechanism.

    Technical Parameters

    Product Type Reversing mini contactor
    Series LC2K
    Product Code LC2K1610P7 
    Number of Main Poles 3P
    Rated Current 16A
    Nominal Motor Power 7.5kW
    Control Coil Voltage 230VAC
    Auxiliary Contact 1NO, normally open
    Purpose For reversible control of three-phase motors
    Weight 0.39 kg

    Main Functions

    • Changing motor rotation direction – allows switching the three-phase motor to run in forward or reverse directions.
    • Three-phase motor control – designed for 3-phase electric motor control circuits.
    • 230VAC control coil – suitable for control schemes utilizing 230V AC voltage.
    • 1NO auxiliary contact – can be used for signaling, a self-holding circuit, a PLC input, or other automation functions.
    • Compact format – convenient for smaller control cabinets, automation panels, and equipment control systems.

    Where is it used?

    • In automatic gates and barriers – for controlling opening and closing mechanisms.
    • In conveyors – to change the direction of movement according to the production process needs.
    • In lifting and lowering mechanisms – in hoists, winches, platforms, and other equipment.
    • In machine tools and workshops – for mechanisms requiring reversing operation.
    • In pump and fan control systems – where a change of direction is technologically required.
    • In industrial control cabinets – for motor and automation circuits.

    Practical Installation Example

    For example, a reversing mini contactor can be used in a three-phase motor control cabinet for a small conveyor. One control button turns on the forward operation of the motor, while another turns it in reverse. The contactor interlocking system prevents both directions from being switched on simultaneously.

    The additional 1NO contact can be used for an indicator light, a PLC input, or a self-holding circuit that keeps the contactor engaged after the control button is released.

    Usage based on needs

    For the electrician/installer: a compact reversing contactor suitable for installation in control cabinets and equipment automation schemes. It is important to correctly connect the phase sequence, control coil, interlocking circuit, and motor protection.

    For the engineer / designer: a suitable solution when designing lower-power reversible motor control systems. When selecting a contactor, it is necessary to evaluate the motor power, operating current, starting conditions, load category, and control voltage.

    For the industrial and maintenance specialist: can be used for reversing control of production equipment, gates, conveyors, hoists, fans, and other mechanisms, as well as for repairing existing contactor systems.

    Pros (Advantages)

    • Reversible control – the motor's direction can be changed forward and backward.
    • 3-pole design – intended for three-phase motor control.
    • 16A rated current – suitable for various smaller motor control circuits.
    • 7.5kW nominal power – a practical solution for many industrial mechanisms.
    • 1NO auxiliary contact – suitable for signaling and automation functions.
    • Compact size – convenient to use in smaller control cabinets.
    • Lightweight – only 0.39 kg.

    Cons / Limitations

    • Designed only for reversing control – for simple motor switching, a single contactor is sufficient.
    • Requires a proper control circuit – it is essential to ensure that both directions are not switched on simultaneously.
    • Requires motor protection – the contactor does not replace a thermal relay, motor protection switch, or circuit breaker.
    • Power depends on operating conditions – before installation, it is necessary to check the specific motor parameters and load type.

    Safety and Installation Notes

    The reversing contactor must be installed and connected according to the electrical diagram, manufacturer documentation, and applicable electrical safety requirements. An incorrectly connected reversing circuit can cause a short circuit, motor damage, or equipment failure.

    • Installation must be performed by a qualified electrician.
    • Before installation work, it is mandatory to disconnect the power supply and verify that there is no voltage in the circuit.
    • Proper mechanical or electrical interlocking must be used so that both contactors are not switched on simultaneously.
    • Appropriate protection against overload and short circuits must be provided in the motor circuit.
    • Before selecting the contactor, you must verify the motor's rated current, power, mains voltage, and load category.
    • The control coil must be connected only to a 230VAC control voltage.

    Quick Selection Guide

    A reversing mini contactor is suitable when you need to reversibly control a three-phase electric motor and the control scheme uses a 230VAC coil. This is a practical solution for smaller motors, gate mechanisms, conveyors, lifting equipment, and various automation systems.

    Control
    Reversing
    Poles
    3P
    Control Coil
    230VAC
    Auxiliary Contact
    1NO
    Suitable when you need to:
    • change the rotation direction of a three-phase motor;
    • control the motor in forward and reverse directions;
    • use a 230VAC control voltage;
    • control circuits up to 16A rated current;
    • use an additional 1NO contact for signaling or automation.
    Check before ordering:
    • whether the motor's rated current and power match the contactor's parameters;
    • whether a 230VAC coil is specifically needed;
    • whether a 1NO auxiliary contact is required;
    • whether motor protection is provided in the control cabinet;
    • whether the reversing circuit requires additional control buttons, relays, or indicator lights.
    Important reminder:
    The reversing contactor must be wired according to a correct reversible motor control diagram. Incorrect phase wiring or interlocking circuit connection can damage the contactor, motor, or the entire control system.

    FAQ – Frequently Asked Questions

    What is a reversing contactor?
    It is a contactor or an assembly of contactors designed to change the rotation direction of a three-phase electric motor. It allows the motor to run in forward and reverse directions.
    What does 3P mean?
    3P means that the contactor has three main poles and is designed for controlling three-phase electrical circuits and three-phase motors.
    What does 1NO mean?
    1NO means one normally open auxiliary contact. It can be used for signaling, self-holding circuits, indication, or as an input for automation equipment.
    Is this contactor suitable for simply turning a motor on?
    Yes, but if the motor does not need to change its rotation direction, it is usually more economical and simpler to use a single standard contactor with appropriate motor protection.
    Does the contactor protect the motor from overload?
    No. The contactor is intended for turning the motor on, off, and reversing control. For overload protection, an appropriate thermal relay, motor protection switch, or other protective equipment must be used.

    Compact Reversing Contactor for Three-Phase Motor Control

    The reversing mini contactor is a practical choice for motor control systems where the rotation direction needs to be changed. It is suitable for gates, conveyors, hoists, machine tools, fans, and other industrial equipment.

    Thanks to its 3-pole design, 16A rated current, 7.5kW power, 230VAC coil, and 1NO auxiliary contact, this model can be easily integrated into automation, electric motor, and control cabinet systems.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Subscribtion to new arrivals

    privacy policy

    Information