  • LC7K contactor | 3P | 12A | 230VAC coil | 4NO auxiliary contacts | for electric motors and control circuits

    Code: LC7K09004M7
    LC7K series 4-pole contactor with 4 normally open (4NO) power contacts, designed for AC-1 category circuits. The contactor has a 230VAC control coil and is suitable for loads up to 440VAC and 20A in AC-1 operation. It can be used in various automation, control, heating, lighting and other electrical circuits. 
  • LC7K Contactor – 4P, 4NO, 20A, AC-1, 230VAC coil

    K-series 4-pole contactor with 4 normally open (4NO) power contacts, designed for AC-1 category circuits. The contactor features a 230VAC control coil, is rated for loads up to 440VAC and 20A in AC-1 mode, and can be used in various automation, control, heating, lighting, and other electrical circuits.

    Key concept:
    4-pole contactor with 4NO contacts, designed for switching AC-1 category loads. It is suitable for applications where four separate circuits or four conductors need to be controlled simultaneously using a 220–230VAC control voltage.
    Number of poles
    4P
    Contact configuration
    4NO
    Control coil
    230VAC
    Utilization category
    AC-1

    Operating principle

    The contactor operates on an electromagnetic principle. When a 220–230VAC voltage is applied to the control coil, the contactor's electromagnet attracts the mechanism, closing the four normally open power contacts. This energizes the electrical circuit or load connected to the contactor.

    When the control voltage is disconnected, the coil no longer attracts the mechanism, the contacts return to their initial position, and the circuit is disconnected. This operating principle allows the contactor to be used for automatic load control, remote switching, and in systems managed by timers, relays, switches, or controllers.

    Why is the 4P 4NO contact configuration important?
    4P 4NO means the contactor has four normally open power contacts. When the coil is energized, all four contacts close simultaneously. This is convenient when you need to switch several independent circuits with a single control signal or control a multi-conductor load at once.

    Technical specifications

    Manufacturer Schneider Electric
    Series LC7K  
    Model / Code LC7K09004M7
    Product type Electromagnetic contactor
    Number of poles 4P
    Contact configuration 4NO – 4 normally open contacts
    Utilization category AC-1
    Rated operational current AC-1 20 A
    Rated operational voltage AC-1 Up to 440VAC
    Control coil voltage 230VAC
    Control coil frequency 50 / 60 Hz
    Coil type AC coil, silent version
    Mounting type DIN rail or screw mounting, depending on the mounting solution
    Terminal type Screw terminals
    Weight 0.178 kg

    Where is it used?

    • Lighting control circuits – for group switching of light fixtures, lighting zones, or advertising signs.
    • Heating systems – for controlling electric heaters, heating sections, or other resistive loads.
    • Automation panels – for switching loads based on a signal from a relay, timer, PLC, or another controller.
    • Commercial and industrial facilities – when multiple separate circuits need to be switched simultaneously.
    • Building engineering systems – in ventilation, alarm, control, and other auxiliary electrical circuits, considering the load category.

    Practical usage example

    For example, the contactor can be mounted in an automation panel where a 220–230VAC control signal from a timer, thermostat, switch, or controller activates the contactor's coil. Once the coil is energized, the four 4NO contacts close, simultaneously supplying power to four separate AC-1 category circuits.

    This solution can be used for heating circuits, lighting zones, auxiliary loads, or other systems where centralized and automatic control of multiple circuits is required.

    Usage by professionals

    Electrician: A compact contactor suitable for installation in control panels, DIN rails, or other electrical distribution solutions. The four NO contacts allow for convenient control of several circuits with a single coil control signal.

    Designer / Engineer: Suitable for systems requiring a 4-pole AC-1 contactor with a 220–230VAC coil. Before selection, it is essential to evaluate the load type, current, voltage, switching frequency, and the specific circuit's utilization category.

    Maintenance Technician: Can be used to replace an identical code or equivalent parameter contactor in automation and control systems. When replacing, it is recommended to verify the contact configuration, coil voltage, and load category.

    Pros

    • 4P 4NO contact configuration – ability to control four circuits simultaneously.
    • 20A in AC-1 category – suitable for resistive and other AC-1 loads according to technical specifications.
    • TeSys K series – compact Schneider Electric contactor for automation systems.
    • Silent operation coil – reduced operating noise compared to standard solutions.
    • Screw terminals – convenient wire connection for panel mounting.
    • Compact weight – approx. 0.178 kg.

    Cons / Limitations

    • Designed for AC-1 category – before using for motors, AC-3 category and specific load parameters must be evaluated.
    • 4NO contacts – the contactor does not have NC power contacts.
    • Additional protection required – the circuit must include properly selected circuit breakers, fuses, relays, or other protective components.
    • Not a full motor starter – for motor protection, additional thermal relays, motor circuit breakers, or other components may be needed.

    Safety and installation notes

    The contactor is an electrical control device; therefore, its selection and installation must be performed after evaluating the specific system load, utilization category, control voltage, and required protective measures.

    • Installation must be performed by a qualified electrician.
    • Before installation, disconnect power and check that there is no voltage in the circuit.
    • Check the control coil voltage – this version is intended for 230VAC.
    • Do not exceed rated parameters – up to 20A in AC-1 category and up to 440VAC according to specified operating conditions.
    • For motor loads, it is necessary to separately evaluate AC-3 category, inrush currents, and motor protection.
    • Use appropriate wire cross-sections, protective devices, and follow electrical installation requirements.

    Quick selection guide

    This is a suitable choice when four normally open power contacts and a 220–230VAC coil are needed for controlling AC-1 category circuits. It is particularly practical in automation panels, lighting, heating, and other resistive load control systems.

    Contacts
    4NO
    Poles
    4P
    Coil
    230VAC
    Load
    20A AC-1
    Suitable when you need:
    • four normally open contacts in one contactor;
    • a 230VAC control coil;
    • control of AC-1 category loads;
    • a compact contactor for an automation panel;
    • switching four circuits with a single control signal.
    Check before ordering:
    • whether the control coil voltage must be 230VAC;
    • whether the load falls under the AC-1 utilization category;
    • whether the 20A rated current is sufficient for your specific system;
    • whether additional protection and auxiliary contacts are needed.
    Important reminder:
    Before replacing an old component, it is necessary to check its contact count, control voltage, utilization category, and load parameters.

    FAQ – Frequently Asked Questions

    Is this a 3-pole contactor?
    No, this is a 4-pole contactor with 4 normally open (4NO) contacts.
    What is the coil voltage of this contactor?
    The control coil of this model is designed for 220–230VAC, 50/60 Hz frequency.
    What does 4NO mean?
    4NO means four normally open contacts. When the coil is de-energized, the contacts are open; when voltage is applied to the coil, all four contacts close.
    Is the contactor suitable for controlling a motor?
    This model is rated for AC-1 category. Before using for motors, it is essential to evaluate motor power, AC-3 category, inrush currents, and necessary protection measures.
    Can the contactor be mounted on a DIN rail?
    The contactor can be mounted on a DIN rail or fixed with screws, depending on the electrical panel design and mounting requirements.
    Is the contactor alone sufficient to protect the entire system?
    No. The contactor is intended for switching circuits. For protection against short circuits, overloads, or other faults, properly selected circuit breakers, fuses, relays, or other protective apparatus must be used.

    Compact 4P contactor for automation and AC-1 load control

    This is a 4-pole 4NO contactor with a 230VAC coil, designed for reliable switching of multiple circuits in automation, lighting, heating, and other electrical control solutions.

    With 4NO contacts, a 20A AC-1 current rating, a compact housing, and a silent operation coil, this contactor is a practical choice for professional electrical panels requiring multi-load control with a single signal.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.