    FAP06C20030AC – Promfactor Baltic ECO FAP6-AC series circuit breaker with residual current protection (RCBO): 2P (1P+N), curve C 20 A, residual current 30 mA, type AC, breaking capacity 6 kA. Overload, short-circuit and residual current protection in one device – for one single-phase ~230 V circuit where each circuit needs its own residual current protection.

    Key idea:
    The RCBO protects the 20 A circuit cable against overload and short circuit, and the 30 mA residual module protects people against electric shock. Type AC responds to sinusoidal AC leakage currents – suitable for lighting, heating and ordinary socket circuits. In case of leakage only this circuit trips, the others keep working.
    Rated current / curve
    C20 (20 A)
    Residual current
    30 mA (0.03 A), type AC
    Breaking capacity
    6 kA
    Poles / voltage
    2P (1P+N) / ~230 V

    Operating principle

    The breaker is mounted in the panel on a DIN rail and connected to one single-phase circuit: phase and neutral pass through the device, the PE conductor does not.

    The thermal release responds to sustained overload above 20 A, the electromagnetic release to short-circuit current according to curve C (C – 5–10 In, for circuits with higher inrush currents). The residual module compares phase and neutral currents and disconnects both poles at 30 mA.

    Result – each circuit has its own residual current protection: a fault in one circuit does not switch off the whole house or apartment, and the fault is easier to locate.

    Why choose FAP06C20030AC?
    One modular device instead of a separate circuit breaker and RCD – a clearer panel layout and selective residual current protection for each circuit; breaking capacity 6 kA.

    Technical specifications

    Product typeCircuit breaker with residual current protection (RCBO)
    Manufacturer / codePromfactor Baltic / FAP06C20030AC
    SeriesECO FAP6-AC
    Number of poles2P (1P+N)
    Rated current (In)20 A
    Tripping curveC
    Rated residual current (IΔn)30 mA (0.03 A)
    Residual current typeAC
    Ultimate breaking capacity (Icu)6 kA (6 000 A)
    Rated voltage (Ue)~230 V
    Mounting35 mm DIN rail

    Main functions

    • Overload protection – the 20 A circuit cable does not overheat.
    • Short-circuit protection C – withstands higher inrush currents of motors, transformers and LED drivers.
    • Residual current protection 30 mA – additional protection of people against electric shock.
    • Type AC – detects sinusoidal AC leakage currents.
    • Breaking capacity 6 kA – sufficient for most residential panels; check the prospective short-circuit current before installation.
    • Separate protection for each circuit – in case of leakage only one circuit trips.

    Where is it used?

    • Apartment and house panels with per-circuit residual current protection
    • Socket circuits
    • Bathroom and wet room circuits
    • Kitchen appliance circuits
    • Outdoor sockets and lighting
    • Office workstation circuits
    • Panel upgrades where there is no space for a separate RCD

    Use by need

    For the apartment or house owner.
    A fault in one circuit does not switch off the whole home – lighting and other appliances stay on.
    For the installing electrician.
    One device instead of two – faster installation and fewer connections in the panel.
    For the designer.
    The ECO FAP6-AC series offers curves B and C – easy to match to the load.

    Practical application

    If in an apartment the kitchen sockets are supplied by a separate 20 A circuit and a leakage there should not switch off the whole apartment, protect this circuit with FAP06C20030AC: overload, short circuit and 30 mA leakage will disconnect only the kitchen sockets.

    Advantages

    • Overload, short-circuit and residual current protection in one device
    • 30 mA additional protection of people
    • Breaking capacity 6 kA
    • Curve C 20 A
    • Selective protection – only one circuit trips
    • "T" button for periodic testing

    Disadvantages / limitations

    • Type AC is not suitable for circuits with inverters, frequency converters or EV charging
    • Intended for single-phase circuits only
    • More expensive than one shared RCD for several breakers
    • Curve and current must match the cable cross-section

    Safety and installation notes

    • Installation by a qualified electrician after disconnecting the supply and verifying absence of voltage
    • The circuit cable cross-section must match 20 A protection
    • Connect phase and neutral according to the device marking; do not route PE through it
    • Do not interconnect the neutrals of different RCBOs
    • Check that the prospective short-circuit current does not exceed 6 kA
    • After installation, test with the "T" button and an RCD tester

    Quick selection guide

    2P (1P+N)
    C20
    30 mA
    type AC
    6 kA
    ~230 V
    Suitable when you need:
    • separate residual current protection for one circuit
    • protection of a 20 A circuit
    • overload, short-circuit and residual current protection in one device
    Check before use:
    • whether the cable suits 20 A protection
    • whether curve C suits the load
    • whether type AC suits the connected equipment
    • whether the prospective short-circuit current is ≤ 6 kA
    Important reminder: An RCBO does not replace protective earthing or periodic inspection of the electrical installation.

    FAQ

    Does FAP06C20030AC protect against short circuit?
    Yes – it contains a curve C circuit breaker and 30 mA residual current protection.
    What is the difference between curves B and C?
    B trips at 3–5 In, C at 5–10 In; C suits higher inrush currents.
    Is it suitable for inverters or frequency converters?
    No – choose type A, F or B for such circuits.
    What does 6 kA mean?
    It is the ultimate breaking capacity – the device safely interrupts short-circuit current up to 6000 A.
    Can it protect several circuits?
    One circuit per RCBO is recommended – that keeps selectivity.
    How often should the "T" button be pressed?
    Periodically, for example every few months, and after work in the panel.

    Modular circuit breaker with residual current device | 2P | 20A | C | 6kA | 0.03A | type AC | DIN | ECO FAP6-AC | Promfactor Baltic | FAP06C20030AC | 4779040153767

    Promfactor Baltic FAP06C20030AC – circuit breaker with residual current protection ECO FAP6-AC 2P C20 30 mA type AC, 6 kA, DIN – protection of a single-phase circuit against overload, short circuit and residual currents.

    Published: 2026-11-07 · Parameters according to the supplier's specification: 2026-11-06

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information