Products catalog

  • Modular DC miniature circuit breaker for solar PV | 2P | 25A | 1000VDC | 6kA | C | DIN | Elsp Group | ES-TXL7-25PV

    Code: ES-TXL7-25PV

    Two-pole DC circuit breaker for PV strings and battery circuits: 25 A, C characteristic, up to 1000 V DC, Icu 6 kA, 2 DIN modules. Protects against overload and short circuit and breaks “+” and “−” simultaneously.

  • Modular DC miniature circuit breaker for solar PV | 2P | 25A | 1000VDC | 6kA | C | DIN | Elsp Group | ES-TXL7-25PV

    ES-TXL7-25PV is a two-pole direct current (DC) miniature circuit breaker for protecting PV strings, inverter inputs and battery circuits. One pole is wired into the “+” conductor and the other into the “−” conductor, so switching off interrupts both wires. The breaker trips on overload (thermal release) and on short circuit (magnetic release).

    Key point:
    A DC arc does not extinguish by itself the way an AC arc does, so a standard AC breaker is not suitable for DC circuits. ES-TXL7-25PV is designed specifically for DC circuits up to 1000 V, and the 25 A rating with C characteristic suits PV strings, combiner boxes and small battery systems. One module protects the whole DC circuit and lets you isolate it manually.
    Rated current
    25 A, C characteristic
    Operating voltage
    up to 1000 V DC (2P)
    Breaking capacity
    Icu 6 kA
    Width
    36 mm – 2 modules

    How it works

    The breaker mounts on a 35 mm DIN rail in a DC distribution board or PV combiner box. The source (PV string or battery) is connected to the top terminals 1 and 3, the load (inverter, charge controller) to the bottom terminals 2 and 4: one pole for the “+” circuit, the other for the “−” circuit.

    On a sustained overload the thermal release trips; on a short circuit the magnetic release trips. Both poles are mechanically linked and open together. The arc formed when breaking DC current is extinguished in the arc chute.

    The result is a protected DC cable run and a handle that lets you safely isolate a string or battery during maintenance, after the load has been switched off.

    Why choose ES-TXL7-25PV?
    A single 36 mm module combines DC overload and short-circuit protection with manual two-pole isolation up to 1000 V DC – no separate fuse holders needed in PV circuits up to 25 A.

    Technical specifications

    Product type Modular DC miniature circuit breaker (MCB) for solar PV and DC circuits
    Manufacturer Elsp Group
    Product code ES-TXL7-25PV
    Number of poles 2P (separate poles for “+” and “−” circuits)
    Rated current (In) 25 A
    Operating voltage (Ue) 12–1000 V DC (2P)
    Ultimate breaking capacity (Icu) 6 kA
    Tripping characteristic C
    Releases thermal (overload) and magnetic (short circuit)
    Current type direct current (DC) only
    Terminal marking and wiring 1–2 and 3–4; source at the top (1, 3), load at the bottom (2, 4)
    Width 36 mm (2 modules)
    Mounting 35 mm DIN rail
    Degree of protection IP20 (install in a board or enclosure)
    Operating temperature −25…+70 °C
    Standard IEC/EN 60947-2

    Main functions

    • Overload protection – the thermal release opens the circuit when current stays above 25 A, protecting the DC cable from overheating.
    • Short-circuit protection – the magnetic release quickly interrupts fault currents up to 6 kA.
    • Two-pole isolation – “+” and “−” are broken simultaneously – no single pole is left connected after switching off.
    • DC arc quenching – designed for direct current up to 1000 V, where the arc does not break by itself.
    • Manual isolation – the handle disconnects a string or battery for maintenance or inverter replacement.
    • Compact size – 36 mm width saves space on the DIN rail and in the PV combiner box.

    Where is it used?

    • PV string isolation and reverse-current protection upstream of a grid inverter
    • Solar combiner boxes
    • PV input protection of hybrid inverters
    • Input and output circuits of MPPT charge controllers
    • Battery circuits in cottages, camper vans and off-grid systems
    • DC power distribution for telecom and automation
    • DC distribution boards in commercial and industrial buildings

    Use by need

    For PV installers.
    One module per string – a clear isolation point at the inverter and cable protection against reverse current from parallel strings or a battery.
    For cottage or off-grid system owners.
    Lets you safely disconnect the solar panels from the charge controller or battery before cleaning, maintenance or equipment replacement.
    For panel builders.
    A standard 36 mm DIN module that is easy to plan into a DC board or combiner box layout.

    Practical example

    If a country house has an approx. 8 kW system with two strings of 10 modules each, and each string has a short-circuit current of about 14 A, then a separate ES-TXL7-25PV is installed for each string at the hybrid inverter: the “+” wire goes to one pole, the “−” wire to the other, string at the top, inverter at the bottom. Before replacing the inverter or checking connections, switch the inverter off first, then isolate the strings with the breaker handle. In such a single-string circuit the breaker serves mainly as an isolation point: it will not trip on the string’s own short-circuit current (about 14 A, below the 25 A rating); its protective function acts against reverse current fed back from parallel strings, the inverter or a battery.

    Pros

    • Designed for direct current up to 1000 V DC
    • Isolates both poles in one movement
    • Overload and short-circuit protection in one module
    • Icu 6 kA breaking capacity
    • C characteristic – suitable for DC cable protection
    • Compact – 36 mm, standard DIN mounting
    • Wide operating temperature range −25…+70 °C

    Cons / limitations

    • DC circuits only – for alternating current (AC) choose an AC circuit breaker
    • No polarity marks (+/−) on the housing – follow the direction: source at the top, load at the bottom, and check the label of the actual unit
    • Icu 6 kA – large lithium battery systems with higher short-circuit current need a DC fuse with higher breaking capacity
    • IP20 – outdoors only inside a sealed enclosure
    • Does not replace a separate DC disconnector or emergency shutdown device where the design or fire-safety requirements call for one

    Safety and installation notes

    • In daylight PV string conductors are always live – before installation disconnect the string at its connectors or cover the modules.
    • Do not disconnect PV connectors (MC4) or the breaker under load while the inverter is running – switch the inverter off first.
    • Follow the wiring direction: source to terminals 1 and 3 (top), load to terminals 2 and 4 (bottom); wire the “+” and “−” circuits through different poles.
    • Before switching on, check string polarity and voltage with a multimeter – open-circuit voltage on a cold day must not exceed 1000 V.
    • Tighten the terminals firmly and recheck after the first weeks of operation – a loose DC contact heats up and can cause an arc.
    • Select the cable cross-section according to the design and the 25 A rating; use PV cable and ferrules.
    • Installation and connection must be carried out by a qualified electrician.

    Quick selection guide

    2P
    25 A
    1000 V DC
    Icu 6 kA
    C characteristic
    DIN 36 mm
    Suitable when you need to:
    • protect and isolate a PV string up to 1000 V DC
    • protect a DC cable with an operating current below 25 A
    • disconnect solar panels from an MPPT controller or inverter
    • protect a small battery circuit whose short-circuit current does not exceed 6 kA
    Check before use:
    • string Voc at the lowest temperature ≤ 1000 V
    • string Isc and design margin match the 25 A rating
    • cable current-carrying capacity not less than 25 A
    • prospective battery short-circuit current ≤ 6 kA
    • wiring direction – source at the top, load at the bottom
    Important reminder: ES-TXL7-25PV does not replace a surge protective device (SPD), PV string fuses where parallel strings require them, or a separate DC disconnector where the design requires one. It is not suitable for AC circuits.

    FAQ

    Can this breaker be used in an AC circuit?
    No, it is intended for direct current circuits only – for AC choose an AC circuit breaker.
    How do I connect the “+” and “−” wires?
    Connect the source to the top terminals 1 and 3 and the load to the bottom terminals 2 and 4, with the “+” circuit through one pole and the “−” circuit through the other.
    Is it suitable for a 1000 V PV string?
    Yes, provided the string open-circuit voltage at the lowest local temperature does not exceed 1000 V.
    Is 25 A right for my string?
    The rating must be higher than the string short-circuit current Isc with the design margin and must not exceed the cable current-carrying capacity.
    Can it protect a battery?
    Yes, if the battery short-circuit current does not exceed 6 kA; large lithium systems require a DC fuse with higher breaking capacity.
    Does it replace a DC isolator or firefighter switch?
    No – if the design or fire-safety requirements call for a separate DC disconnector or emergency shutdown, it must be installed in addition.

    Modular DC miniature circuit breaker for solar PV | 2P | 25A | 1000VDC | 6kA | C | DIN | Elsp Group | ES-TXL7-25PV

    Two-pole DC miniature circuit breaker ES-TXL7-25PV (Elsp Group) – 25 A, C characteristic, up to 1000 V DC, Icu 6 kA, 36 mm DIN module. Designed for overload and short-circuit protection of PV strings, inverters, MPPT controllers and battery circuits, and for safe isolation of both poles.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Rear L-type panel bracket for solar modules | 30mm | Goomax End clamp (BLK)
    Code: GM-EC-30H

    Goomax GM-EC-30H is a high-quality L-type end clamp designed for mounting 30 mm thick solar panels to mounting rails. This component is made of durable aluminum alloy with a corrosion-resistant black anodized coating (BLK), ensuring long-lasting performance even in extreme outdoor conditions. Used as the end fixing point in the module mounting system, this clamp is compatible with most standard Goomax and other mounting systems. 

    Price 2.29 € VAT incl.
    ( 1.89 € VAT excl. )
    Solar PV cable | H1Z2Z2-K | 1x4 mm² | black | 1.5 kV DC | EN 50618 | Dca | IEMMEQU HAR
    Code: H1Z2Z2K

    The cable is designed for connecting photovoltaic (solar energy) systems and interconnecting solar modules. This cable offers excellent resistance to ultraviolet (UV) rays, ozone, atmospheric effects, and temperature fluctuations. A durable and flexible single-core copper cable with double insulation ensures long service life and safe use even in the most challenging outdoor conditions. Suitable for installation both indoors and outdoors.

    Price 0.98 € VAT incl.
    ( 0.81 € VAT excl. )
  • privacy policy

    Information