Modular residual current circuit breaker with overcurrent protection (RCBO) | 2P | 25A | C | 4,5kA | 0.03A | DIN | Vecas | L7L-25/1N/C/003-A
Code: L7L-25/1N/C/003-APrice 13.57 € VAT incl.( 11.21 € VAT excl. )A combined residual current circuit breaker with overload and short-circuit protection (RCBO), designed to ensure both human safety against electric shock and the protection of wiring and equipment against electrical faults. Operating according to the IEC61009-1 standard, this device combines the functions of a circuit breaker and residual current relay in a single enclosure. It is a compact, efficient, and reliable solution for single-phase 230–240 V electrical systems.
-
Modular residual current circuit breaker with overcurrent protection (RCBO) | 2P | 25A | C | 4,5kA | 0.03A | DIN | Vecas | L7L-25/1N/C/003-A
Vecas residual current circuit breaker with overcurrent protection (RCBO) 2P, C25, 30 mA, breaking capacity 4,5 kA. One device protects a single circuit against overload, short circuit and residual current.
Key idea:
One device protects one circuit against overload, short circuit and leakage at once, so a fault in one circuit does not switch off the whole board. Suitable for apartment, house and commercial boards where each circuit needs its own 30 mA protection.Poles
2PRated current
C25 (25 A)Residual current
30 mABreaking capacity
4,5 kAOperating principle
The device is mounted on a 35 mm DIN rail and connected into a single circuit – phase and neutral pass through it.
The circuit breaker part disconnects the circuit on overload or short circuit according to the C characteristic. The residual current part compares the phase and neutral currents and trips when the difference reaches 30 mA.
Result – the circuit cable is protected against overheating and short circuit, people against residual current, while the other circuits stay on.
Why choose L7L-25/1N/C/003-A?
Instead of a separate circuit breaker and RCCB – one device per circuit: less space in the board, and a leak does not switch off the other circuits.Technical specifications
Product type Residual current circuit breaker with overcurrent protection (RCBO) Manufacturer / code Vecas / L7L-25/1N/C/003-A Series — Number of poles 2P Rated current (In) 25 A Tripping characteristic C Rated residual current (IΔn) 30 mA (0,03 A) Rated breaking capacity (Icn) 4,5 kA Residual current type not stated Mounting 35 mm DIN rail Main functions
- Overload protection – the circuit cable does not overheat when 25 A is exceeded for a long time
- Short-circuit protection – the C characteristic quickly disconnects short-circuit current
- Residual current monitoring – disconnects the circuit when leakage reaches 30 mA
- Circuit-by-circuit selectivity – leakage in one circuit does not switch off the others
- Test button – lets you check that the residual current part works
Where is it used?
- Bathroom socket circuit
- Kitchen socket circuit
- Outdoor sockets and garden equipment
- Washing machine or water heater circuit
- Office and shop circuits
- House and country house boards
Use by need
Electrician.
Fit each circuit with separate residual current and overcurrent protection in one device.Apartment owner.
Protect the bathroom or kitchen circuit so that a leak does not switch off the whole apartment.Commercial premises manager.
Avoid the whole board tripping because of one faulty circuit.Practical application
If the bathroom socket circuit in an apartment is protected by a C25 circuit breaker and the cable is rated for it, it can be replaced with this RCBO – the circuit gains 30 mA residual current protection, and in case of leakage the other circuits stay on.Advantages
- Overload, short-circuit and residual current protection in one device
- Leakage in one circuit does not switch off the others
- Breaking capacity 4,5 kA
- Standard DIN rail mounting
- Takes less space than a separate breaker and RCCB
Disadvantages / limitations
- Residual current type (AC or A) is not stated in this description – check the marking on the housing
- Protects only one circuit – several circuits need several devices
- The manufacturer’s datasheet is not available – IP rating, temperature and terminal data are not stated
Safety and installation notes
- Install only with the voltage disconnected and its absence verified.
- Work must be carried out by a qualified electrician.
- The circuit cable cross-section must match the 25 A protection.
- Do not connect the neutral downstream of the device to the neutral of other circuits or to PE – otherwise it will trip unnecessarily.
- After installation press the test button “T” and check that it trips.
Quick selection guide
2PC2530 mA4,5 kADIN 35 mmSuitable when you need:- protection of one circuit against overload, short circuit and leakage
- a leak in one circuit not to switch off the others
- a bathroom, kitchen or outdoor socket circuit
Check before use:- The residual current type (AC or A) on the housing
- Whether 25 A matches the circuit cable cross-section
- Whether there is enough space on the DIN rail
Important reminder: An RCBO does not replace proper earthing – the installation must have a PE conductor.FAQ
How does an RCBO differ from an RCCB?
An RCBO also protects against overload and short circuit, an RCCB only against leakage.How many circuits does one device protect?
One circuit.What does the C characteristic mean?
The C characteristic tolerates higher inrush currents, so it suits general circuits with motors or transformers.Which residual current type is it?
The type is marked on the housing – you can confirm it with us before buying.What does 4,5 kA mean?
It is the highest short-circuit current the device can safely interrupt.How do I check that the device works?
Press the test button “T” – a working device must trip.Modular residual current circuit breaker with overcurrent protection (RCBO) | 2P | 25A | C | 4,5kA | 0.03A | DIN | Vecas | L7L-25/1N/C/003-A
Vecas L7L-25/1N/C/003-A – C25 30 mA RCBO 2P 4,5 kA for protecting one circuit against overload, short circuit and residual current.
Published: 2026-11-15 · Manufacturer’s datasheet not available – product marking parameters are stated
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.The IP protection class indicates the device's resistance to environmental factors.

The first digit indicates protection against dust and solid objects.
The second digit indicates protection against moisture.First digit values:
X — Untested;
0 — No protection;
1 — Protected against solid objects larger than 50 mm;
2 — Protected against solid objects larger than 12.5 mm;
3 — Protected against solid objects larger than 1 mm;
4 — Protected against solid objects larger than 1 mm;
5 — Dust protected;
6 — Totally dustproof.
Second digit values:X — Untested;
0 — No protection;
1 — Protected against vertically falling water drops;
2 — Protected against water drops falling at a 15º angle;
3 — Protected against rain falling at a 60º angle;
4 — Protected against water splashes;
5 — Protected against water jets;
6 — Protected against large amounts of water;
7 — Protected against short-term immersion in water up to 1 meter deep;
8 — Protected against long-term immersion in water up to 3 meters deep.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products