Products catalog

Modular leakage relays | installed in electrical distribution boxes | panels

  • Modular residual current relays are specialized electrical devices designed to detect and protect against leakage currents that can pose a danger to people and equipment. These relays are often used in electrical distribution systems to ensure safety and reliability.

  • RCD and RCBO guide: from an apartment panel to an industrial site

    A residual current device (RCD) is the only device in the panel whose main purpose is to protect human life. This guide is written for three readers: homeowners, who want to understand what the electrician is installing; students, who are learning the operating principle and standards; electricians and engineers, who need selectivity, types and borderline cases. Choose your section or read everything in order.

    Colour key: ■ information · ■ benefit, solution · ■ ⚠ check · ■ ⚡ safety, mistakes · In catalogue product in catalogue · Available on request supplied on request

    ELSprendimai recommends – selection in 30 s ↓⌂ For home✎ For students⚙ For electricians and engineers

    Selection in 30 seconds

    Your situation Choose We recommend
    Socket, kitchen or bathroom circuit in an apartment or house (1 phase) 30 mA, type A, 2P, rated current ≥ that of the upstream breaker RCD 2P 40 A 30 mA, type A In catalogue
    Three-phase supply in a house, one RCD for several circuits 30 mA, type A, 4P RCD 4P 40 A 30 mA, type A In catalogue
    Separate protection for each circuit (fridge, heating, alarm) RCBO 30 mA, type A RCBO 2P 16 A 30 mA, type A, 4.5 kA or RCBO 2P 16 A 30 mA, type A, 10 kA In catalogue
    Simple resistive load, lowest price, needed today 30 mA, type AC – only without electronics RCD 2P 40 A 30 mA, type AC In catalogue in stock
    Heat pump, inverter air conditioner, inverter washing machine 30 mA, type F (or according to the manufacturer's instructions) Available on request Send an enquiry
    EV charging station without integrated 6 mA DC detection, three-phase frequency converter, PV inverter (if required by the manufacturer) 30 mA, type B Available on request Send an enquiry
    Incomer, selectivity with 30 mA circuit RCDs 300 mA, S (selective), type A Available on request Without selectivity: 4P 63 A 300 mA, type A
    Long outdoor lighting line, farm building without sockets 100 mA or 300 mA, type A (not for protection of persons) RCD 4P 40 A 100 mA, type A
    Special locations: childcare facilities, individual bathroom or pool appliances 10 mA, type A RCD 2P 25 A 10 mA, type A, 4P 25 A 10 mA
    ⚡ Most important: additional protection of people against electric shock is provided only by ≤30 mA residual current protection. 100 mA and 300 mA protect against fire. An RCD does not protect against overload and short circuit – for that you need a circuit breaker or RCBO.

    Solution levels: from simple to professional

    Level Site Typical residual current protection scheme
    1 Basic Apartment, summer cottage 1–2 RCD 30 mA (type A), 2–4 circuits each
    2 Comfortable Detached house Separate RCD 30 mA groups: rooms, kitchen + bathroom, outdoor sockets; RCBO 30 mA for fridge, heating, alarm
    3 Modern House with heat pump, EV, solar plant Level 2 + type F for the heat pump, type B or RDC-DD station for the EV, PV per inverter manufacturer; 300 mA S at the incomer
    4 Commercial Office, shop, workshop 300 mA S at the incomer, RCBO 30 mA in circuits, 100 mA for long lines; documented selectivity
    5 Industrial Production, frequency converters, large motors Type B for frequency converter circuits, residual current monitoring relays with current transformers, adjustable IΔn and delay

    Diagram: how it is often done and how it should be

    ✗ WRONG

    Incomer 3×25 A
    ↓
    ① One RCD 30 mA, type AC – for the whole house
    ↓
    Sockets
    Fridge
    Heat pump ②
    Outdoor lights ③

    ✓ CORRECT

    Incomer 3×25 A
    ↓
    ④ RCD 300 mA, type S (selective)
    ↓
    ⑤ RCD 30 mA A
    room sockets
    ⑤ RCD 30 mA A
    kitchen, bathroom
    ⑥ RCBO 30 mA A
    fridge
    ⑦ RCBO / RCD 30 mA F
    heat pump
    1. One RCD for the whole house – any leakage disconnects everything, including the fridge and heating. Moreover, the background leakages of all circuits add up and the RCD trips „for no reason“.
    2. Type AC for inverter appliances – an AC device may not recognise the leakage current of a frequency converter and fail to trip when needed.
    3. Outdoor line on the same RCD – moisture in outdoor boxes and long lines are the most common causes of nuisance tripping.
    4. Selective 300 mA at the incomer protects the building against fire and trips with a delay, so the fault is first cleared by the circuit RCD.
    5. Groups of 2–4 circuits – a fault disconnects only part of the house and the cause is easy to find.
    6. RCBO for critical circuits – the fridge or alarm does not depend on faults in other circuits.
    7. Type according to the load – type F for the heat pump (or as specified by the manufacturer).
    ⌂ For homeowners: what you need to know

    An RCD checks whether all the current flowing into an appliance comes back. If part of the current „leaks“ to earth through a person or damaged insulation, the RCD disconnects the circuit within tens of milliseconds.

    • Press the „T“ button every six months – the RCD must trip. If it does not, it must be replaced.
    • RCD tripped? First unplug recently switched-on appliances and outdoor equipment, then switch the RCD back on. If it still trips – call an electrician.
    • ⚠ Never tape down or bypass the RCD – that removes the only protection against a fatal shock.
    • Buying a new inverter appliance (heat pump, air conditioner)? Ask your electrician whether your RCD type is suitable.
    Kibirkštis
    KibirkštisIs one RCD enough for a house?
    Fazė
    FazėIt will protect, but any leakage will disconnect the whole house. It is more convenient and safer to have several RCDs with 2–4 circuits each, or RCBOs for the most important circuits.
    ✎ For students: operating principle and standards

    Principle. The phase and neutral conductors pass through a differential (summation) current transformer. When IL = IN, the magnetic fluxes cancel out. When part of the current leaks to earth, the difference ΔI induces a current in the secondary winding and the release disconnects all poles.

    Parameter Value per EN 61008 / 61009 (general type)
    Non-operating current 0.5 × IΔn – the RCD must not trip
    Operating current between 0.5 and 1.0 × IΔn (type AC)
    Break time at IΔn ≤ 300 ms
    Break time at 5 × IΔn ≤ 40 ms
    S (selective) type trips with a delay – time at IΔn 130–500 ms

    Earthing systems. In a TN-C system (PEN conductor) an RCD does not work correctly – downstream of the RCD, N and PE must be separated (TN-C-S, TN-S). In a TT system residual current protection is mandatory, and the earth electrode resistance is checked against the condition RA × IΔn ≤ 50 V (HD 60364-4-41).

    Background leakage. Every appliance with a filter has a small leakage. Rule of thumb: the total background leakage of a circuit should not exceed ~30% of IΔn (≈ 9–10 mA for a 30 mA RCD), otherwise nuisance tripping occurs.

    Kibirkštis
    KibirkštisWhy 30 mA and not 50 or 10?
    Fazė
    Fazė30 mA is the threshold below which alternating current flowing through the human body for a short time generally does not cause ventricular fibrillation. 10 mA is used in special locations where the risk is higher.
    ⚙ For electricians and engineers: types, selectivity, borderline cases
    Type Detects Where required Range
    AC Sinusoidal AC Resistive loads only Wide In catalogue
    A AC + pulsating DC (up to 6 mA smooth DC) Home standard: LED, electronics, induction Wide In catalogue
    F A + mixed frequency (up to 1 kHz), up to 10 mA DC Single-phase frequency converters: heat pumps, inverter appliances Available on request
    B F + smooth DC, high frequency Three-phase frequency converters, EV without RDC-DD, PV per manufacturer Available on request
    • Selectivity: the upstream RCD must be type S and its IΔn at least 3 times higher than downstream (e.g. 300 mA S → 30 mA). Two equally fast RCDs in series – no selectivity.
    • Rated current: RCD In ≥ rated current of the upstream protective device; an RCD has no overload or short-circuit protection – it is protected by a circuit breaker.
    • Type A and DC: smooth DC residual current above 6 mA (e.g. from an EV station) can „saturate“ the transformer of a type A RCD – then a type B RCD or a station with RDC-DD is used.
    • Industry: residual current monitoring relays with an external current transformer and adjustable IΔn and delay – in the RCD group.
    • RCBO 4P for three-phase circuits: RCBO 4P 25 A C 30 mA, type A In catalogue.
    Kibirkštis
    KibirkštisHow do I check selectivity on site?
    Fazė
    FazėUse a tester with an RCD function to measure the tripping current and time of each device. The 30 mA circuit RCD must trip within ≤ 300 ms, while the incomer S device must remain on. Record the results in the test report.

    ⚠ What to check before buying

    • Sensitivity IΔn: 10 / 30 / 100 / 300 mA – according to purpose (people or fire).
    • Type: AC / A / F / B – according to the load, not the price.
    • Number of poles: 2P for single-phase, 4P for three-phase networks.
    • Rated current: not lower than the current of the upstream breaker.
    • Selectivity: whether a type S is needed at the incomer.
    • Panel space: RCD 2P – 2 modules, 4P – 4 modules.

    ✗ Most common mistakes

    • 100 / 300 mA RCD for socket circuits – people remain unprotected.
    • Neutral conductors mixed between different RCDs – constant nuisance tripping.
    • PE conductor connected through the RCD – the RCD will never trip on a leakage to PE.
    • RCD in a TN-C system without separating N and PE – the protection does not work.
    • Type AC for inverter appliances – the RCD may fail to trip.
    • Two equally fast RCDs in series – both trip, no selectivity.
    Fazė

    ⚡ Safe installation – Fazė's tip

    All work in the panel only with the voltage disconnected and its absence verified. After installation test the RCD with a tester, not just the „T“ button: the button checks the mechanism, but not the tripping current and time.

    Frequently asked questions

    Asked by Kibirkštis – a young, curious electrician who dares to ask what others won't. Answered by Fazė – an experienced engineer.

    Kibirkštis
    KibirkštisThe RCD trips during a thunderstorm – is it faulty?
    Fazė
    FazėUsually not. The surge leaks to earth through appliance filters and the RCD trips. A surge protection device upstream of the RCD helps.
    Kibirkštis
    KibirkštisRCD or RCBO – which to choose?
    Fazė
    FazėThe protection is the same. An RCBO costs more, but each circuit is independent. In practice: for critical circuits – RCBO, for the others – RCD blocks of 2–4 circuits.
    Kibirkštis
    KibirkštisCan an RCD be installed downstream of another RCD?
    Fazė
    FazėYes, if the upstream one is type S with a higher IΔn (e.g. 300 mA S → 30 mA). Two 30 mA in series make no sense.
    Kibirkštis
    KibirkštisDoes an RCD need earthing?
    Fazė
    FazėThe RCD will trip without PE when current flows through a person, but by then the shock has already happened. With PE the fault is cleared before anyone touches it. Earthing is essential.
    Kibirkštis
    KibirkštisWhat if I need type F or B, which I can't find in the catalogue?
    Fazė
    FazėWrite to us – we supply on request and will select according to the requirements of your equipment manufacturer. Send an enquiry →

    Other related guides

    Modular equipment guide · RCBO group · Circuit breakers · All product selection guides

    Standards: HD 60364-4-41, HD 60364-5-53, EN 61008-1, EN 61009-1, EN 62423, IEC/TR 60755. Checked 2026-11-06.

    This guide is for information only. UAB „Elektrotechnikos sprendimai“ accepts no responsibility for product selection based solely on this guide. Electrical installation work must be carried out by a certified electrician; the final decision is determined by the design and applicable requirements.

    Residual current protection for the whole site – in one order

    More than 200 RCD and RCBO items: types AC and A, 10 / 30 / 100 / 300 mA, 2P and 4P. Types F, B and selective S are supplied on request. Experience in the electrical field since 1998. Send us your list of circuits – we will make a selection and send you an offer.

    Equip the panelGet an offer
    Read more
    Modular residual current device | 4P | 100A | 0.3A | type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4100300A
    Code: FPR4100300A

    Promfactor Baltic FPR4100300A – residual current device (RCD) FPR-A 4P 100 A, 300 mA, type A, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 34.87 € VAT incl.
    ( 28.82 € VAT excl. )
    Modular residual current device | 4P | 100A | 0.1A | type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4100100A
    Code: FPR4100100A

    Promfactor Baltic FPR4100100A – residual current device (RCD) FPR-A 4P 100 A, 100 mA, type A, electromechanical, ≤0.1 s; for residual current protection in a DIN panel.

    Price 31.70 € VAT incl.
    ( 26.20 € VAT excl. )
    Modular residual current device | 4P | 63A | 0.3A | type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4063300A
    Code: FPR4063300A

    Promfactor Baltic FPR4063300A – residual current device (RCD) FPR-A 4P 63 A, 300 mA, type A, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 31.70 € VAT incl.
    ( 26.20 € VAT excl. )
    Modular residual current device | 4P | 32A | 0.3A | type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4032300A
    Code: FPR4032300A

    Promfactor Baltic FPR4032300A – residual current device (RCD) FPR-A 4P 32 A, 300 mA, type A, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 26.04 € VAT incl.
    ( 21.52 € VAT excl. )
    Modular residual current device | 4P | 32A | 0.1A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR4032100AC
    Code: FPR4032100AC

    Promfactor Baltic FPR4032100AC – residual current device (RCD) FPR-AC 4P 32 A, 100 mA, type AC, electromechanical, ≤0.1 s; for residual current protection in a DIN panel.

    Price 19.75 € VAT incl.
    ( 16.32 € VAT excl. )
    Modular residual current device | 4P | 32A | 0.1A | type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4032100A
    Code: FPR4032100A

    Promfactor Baltic FPR4032100A – residual current device (RCD) FPR-A 4P 32 A, 100 mA, type A, electromechanical, ≤0.1 s; for residual current protection in a DIN panel.

    Price 26.04 € VAT incl.
    ( 21.52 € VAT excl. )
    Modular residual current device | 4P | 16A | 0.3A | type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4016300A
    Code: FPR4016300A

    Promfactor Baltic FPR4016300A – residual current device (RCD) FPR-A 4P 16 A, 300 mA, type A, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 26.04 € VAT incl.
    ( 21.52 € VAT excl. )
    Modular residual current device | 4P | 16A | 0.1A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR4016100AC
    Code: FPR4016100AC

    Promfactor Baltic FPR4016100AC – residual current device (RCD) FPR-AC 4P 16 A, 100 mA, type AC, electromechanical, ≤0.1 s; for residual current protection in a DIN panel.

    Price 19.75 € VAT incl.
    ( 16.32 € VAT excl. )
    Modular residual current device | 4P | 16A | 0.1A | type A | DIN | ECO FPR-A | Promfactor Baltic | FPR4016100A
    Code: FPR4016100A

    Promfactor Baltic FPR4016100A – residual current device (RCD) FPR-A 4P 16 A, 100 mA, type A, electromechanical, ≤0.1 s; for residual current protection in a DIN panel.

    Price 26.04 € VAT incl.
    ( 21.52 € VAT excl. )
    Modular residual current device | 2P | 40A | 0.3A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR2040300AC
    Code: FPR2040300AC

    Promfactor Baltic FPR2040300AC – residual current device (RCD) FPR-AC 2P 40 A, 300 mA, type AC, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 16.15 € VAT incl.
    ( 13.35 € VAT excl. )
    Modular residual current device | 2P | 32A | 0.3A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR2032300AC
    Code: FPR2032300AC

    Promfactor Baltic FPR2032300AC – residual current device (RCD) FPR-AC 2P 32 A, 300 mA, type AC, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 16.15 € VAT incl.
    ( 13.35 € VAT excl. )
    Modular residual current device | 2P | 32A | 0.1A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR2032100AC
    Code: FPR2032100AC

    Promfactor Baltic FPR2032100AC – residual current device (RCD) FPR-AC 2P 32 A, 100 mA, type AC, electromechanical, ≤0.1 s; for residual current protection in a DIN panel.

    Price 13.31 € VAT incl.
    ( 11.00 € VAT excl. )
    Modular residual current device | 2P | 25A | 0.3A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR2025300AC
    Code: FPR2025300AC

    Promfactor Baltic FPR2025300AC – residual current device (RCD) FPR-AC 2P 25 A, 300 mA, type AC, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 16.15 € VAT incl.
    ( 13.35 € VAT excl. )
    Modular residual current device | 2P | 16A | 0.3A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR2016300AC
    Code: FPR2016300AC

    Promfactor Baltic FPR2016300AC – residual current device (RCD) FPR-AC 2P 16 A, 300 mA, type AC, electromechanical, ≤0.1 s; for fire protection in a DIN panel.

    Price 16.15 € VAT incl.
    ( 13.35 € VAT excl. )
    Modular residual current device | 2P | 16A | 0.1A | type AC | DIN | ECO FPR-AC | Promfactor Baltic | FPR2016100AC
    Code: FPR2016100AC

    Promfactor Baltic FPR2016100AC – residual current device (RCD) FPR-AC 2P 16 A, 100 mA, type AC, electromechanical, ≤0.1 s; for residual current protection in a DIN panel.

    Price 13.31 € VAT incl.
    ( 11.00 € VAT excl. )
    Modular circuit breaker with residual current device | 2P | 20A | C | 10kA | 0.03A | type A | DIN | ECO FAP10-A | Promfactor Baltic | FAP10C20030A
    Code: FAP10C20030A

    Promfactor Baltic FAP10C20030A – RCBO FAP10-A 2P C20 A, 30 mA, type A, 10 kA; a single device protects a 20 A circuit against overload and residual current.

    Price 28.53 € VAT incl.
    ( 23.58 € VAT excl. )
    Modular circuit breaker with residual current device | 2P | 20A | B | 10kA | 0.03A | type A | DIN | ECO FAP10-A | Promfactor Baltic | FAP10B20030A
    Code: FAP10B20030A

    Promfactor Baltic FAP10B20030A – RCBO FAP10-A 2P B20 A, 30 mA, type A, 10 kA; a single device protects a 20 A circuit against overload and residual current.

    Price 28.53 € VAT incl.
    ( 23.58 € VAT excl. )
    Modular circuit breaker with residual current device | 1P+N | 25A | C | 6kA | 0.1A | type A | DIN | FAP8-A | Promfactor Baltic | FAP08C25100A
    Code: FAP08C25100A

    Promfactor Baltic FAP08C25100A – RCBO FAP8-A 1P+N C25 A, 100 mA, type A, 6 kA; protects a 25 A circuit against overload, short circuit and residual-current fire risk. Not for additional protection of persons – socket, bathroom and outdoor circuits require 30 mA.

    Price 15.49 € VAT incl.
    ( 12.80 € VAT excl. )
    Modular circuit breaker with residual current device | 1P+N | 16A | C | 6kA | 0.1A | type A | DIN | FAP8-A | Promfactor Baltic | FAP08C16100A
    Code: FAP08C16100A

    Promfactor Baltic FAP08C16100A – RCBO FAP8-A 1P+N C16 A, 100 mA, type A, 6 kA; protects a 16 A circuit against overload, short circuit and residual-current fire risk. Not for additional protection of persons – socket, bathroom and outdoor circuits require 30 mA.

    Price 15.21 € VAT incl.
    ( 12.57 € VAT excl. )
    Modular circuit breaker with residual current device | 1P+N | 10A | C | 6kA | 0.1A | type A | DIN | FAP8-A | Promfactor Baltic | FAP08C10100A
    Code: FAP08C10100A

    Promfactor Baltic FAP08C10100A – RCBO FAP8-A 1P+N C10 A, 100 mA, type A, 6 kA; protects a 10 A circuit against overload, short circuit and residual-current fire risk. Not for additional protection of persons – socket, bathroom and outdoor circuits require 30 mA.

    Price 15.56 € VAT incl.
    ( 12.86 € VAT excl. )
    Modular circuit breaker with residual current device | 1P+N | 25A | B | 6kA | 0.1A | type A | DIN | FAP8-A | Promfactor Baltic | FAP08B25100A
    Code: FAP08B25100A

    Promfactor Baltic FAP08B25100A – RCBO FAP8-A 1P+N B25 A, 100 mA, type A, 6 kA; protects a 25 A circuit against overload, short circuit and residual-current fire risk. Not for additional protection of persons – socket, bathroom and outdoor circuits require 30 mA.

    Price 15.49 € VAT incl.
    ( 12.80 € VAT excl. )
    Modular circuit breaker with residual current device | 1P+N | 16A | B | 6kA | 0.1A | type A | DIN | FAP8-A | Promfactor Baltic | FAP08B16100A
    Code: FAP08B16100A

    Promfactor Baltic FAP08B16100A – RCBO FAP8-A 1P+N B16 A, 100 mA, type A, 6 kA; protects a 16 A circuit against overload, short circuit and residual-current fire risk. Not for additional protection of persons – socket, bathroom and outdoor circuits require 30 mA.

    Price 15.21 € VAT incl.
    ( 12.57 € VAT excl. )
    Modular circuit breaker with residual current device | 1P+N | 10A | B | 6kA | 0.1A | type A | DIN | FAP8-A | Promfactor Baltic | FAP08B10100A
    Code: FAP08B10100A

    Promfactor Baltic FAP08B10100A – RCBO FAP8-A 1P+N B10 A, 100 mA, type A, 6 kA; protects a 10 A circuit against overload, short circuit and residual-current fire risk. Not for additional protection of persons – socket, bathroom and outdoor circuits require 30 mA.

    Price 15.56 € VAT incl.
    ( 12.86 € VAT excl. )
    Modular circuit breaker with residual current device | 4P | 40A | C | 6kA | 0.03A | type A | DIN | FAP1-A | Promfactor Baltic | FAP01C400304A
    Code: FAP01C400304A

    Promfactor Baltic FAP01C400304A – RCBO FAP1-A 4P C40 A, 30 mA, type A, 6 kA; a single device protects a 40 A circuit against overload and residual current.

    Price 40.67 € VAT incl.
    ( 33.61 € VAT excl. )