Products catalog

  • Modular single-phase energy meter | 5(45) A | 230 V | 2 tariffs | bidirectional | RS485 Modbus | IP51 | DIN | Carlo Gavazzi EM111DINA

    Code: EM111DINA

    Modular single-phase energy meter Carlo Gavazzi EM111DINA: direct connection, current 5(45) A, 230 V, 2 tariffs, RS485 Modbus.

  • Modular single-phase energy meter | 5(45) A | 230 V | 2 tariffs | bidirectional | RS485 Modbus | IP51 | DIN | Carlo Gavazzi EM111DINA

    EM111DINA is a modular single-phase energy meter by Carlo Gavazzi for metering active energy (kWh) in single-phase 230 V circuits. It is connected directly, current up to 45 A, data transmitted via RS485 Modbus.

    Key point:
    When consumption data must be collected into a PLC, SCADA or energy management system, EM111DINA transmits it via RS485 Modbus – no manual reading needed.
    Current
    5(45) A
    Voltage
    230 V
    Metering
    check metering, class 1 (IEC 62053-21) / B (EN 50470-3)
    Communication
    RS485 Modbus

    Operating principle

    The meter is mounted on a 35 mm DIN rail and connected directly into the phase and neutral circuit – the full load current (up to 45 A) flows through the meter terminals.

    The electronic measuring circuit continuously measures voltage and current, calculates active energy and accumulates it in kWh by 2 tariffs. The display also shows instantaneous values: kW, kvar, V, A, PF, Hz, kW dmd.

    All readings are transmitted via the RS485 Modbus RTU interface to a controller, data logger or building management system.

    Why choose EM111DINA?
    Readings are collected automatically – suitable for energy monitoring and automation.

    Technical specifications

    Product type Modular single-phase energy meter
    Manufacturer Carlo Gavazzi
    Model / code EM111DINA
    Phases 1 phase (L + N)
    Rated voltage 230 V
    Current Ib (Imax) 5(45) A
    Minimum current 0.25 A
    Frequency 50/60 Hz
    Connection direct (no current transformers)
    Accuracy class 1 (IEC 62053-21) / B (EN 50470-3)
    MID approval no
    Tariffs 2 tariffs
    Display LCD, backlit
    Measured values kW, kvar, V, A, PF, Hz, kW dmd
    Pulse output no
    Communication interface RS485 Modbus RTU
    Mounting 35 mm DIN rail
    Width 1 DIN module(s)
    Degree of protection IP51

    Main functions

    • kWh metering – you see the real consumption of a circuit or site.
    • 2 tariffs – energy is counted separately for day / night or other tariffs.
    • Instantaneous values – on the display – kW, kvar, V, A, PF, Hz, kW dmd.
    • RS485 Modbus RTU – data goes to PLC, SCADA or BMS without manual reading.
    • Bidirectional metering – consumed and exported energy counted separately.
    • Data retention – accumulated kWh are not lost when voltage drops out.

    Where is it used?

    • Office and commercial distribution boards
    • Building management systems (BMS)
    • Solar plant and heat pump metering
    • EV charging points
    • Production line and equipment monitoring
    • Data centres and server rooms

    Use by need

    For automation integrators.
    Reads data directly via Modbus RTU into SCADA or PLC.
    For building managers.
    Sees the consumption of each zone or tenant without manual reading.
    For energy engineers.
    Analyses loads and finds where savings are possible.

    Practical application

    If you want to monitor several tenants or machines on one screen, a EM111DINA is installed for each circuit, all are connected on one RS485 line and read via Modbus RTU – the data then goes automatically to SCADA or a controller.

    Pros

    • Simple check metering
    • Direct connection up to 45 A
    • RS485 Modbus for remote reading
    • 2-tariff metering
    • Compact: 1 DIN module(s)
    • Readings retained during power failure

    Cons / limitations

    • No MID approval – not suitable for commercial billing
    • Maximum current 45 A – larger loads need a meter with current transformers
    • Single-phase circuits only

    Safety and installation notes

    • Installation by a qualified electrician with voltage disconnected
    • Install a circuit breaker before the meter according to the cable cross-section
    • Follow the terminal marking (L in / L out / N)
    • Tighten terminals to the correct torque – a loose contact overheats
    • Do not exceed 45 A current
    • The meter does not protect against overload or short circuit

    Quick selection guide

    1 phase
    5(45) A
    230 V
    no MID
    RS485 Modbus
    DIN rail
    Suitable when you need:
    • check metering of consumption
    • remote reading of values
    • direct connection up to 45 A
    Check before use:
    • the circuit is single-phase 230 V
    • the maximum current does not exceed 45 A
    • there is space in the panel (1 DIN mod.)
    Important reminder: without MID approval the meter is intended for check metering, not for billing with the energy supplier or tenants.

    FAQ

    Can it be used for billing a tenant?
    No, the meter has no MID approval – choose a MID meter for that.
    What is the maximum current?
    Direct connection – up to 45 A.
    Are current transformers needed?
    No, the meter is connected directly.
    Are readings lost during a power failure?
    No, accumulated kWh are stored in memory.
    Can it be read remotely?
    Yes, via RS485 Modbus RTU.
    How is it mounted?
    On a 35 mm DIN rail in a panel.

    Modular single-phase energy meter | 5(45) A | 230 V | 2 tariffs | bidirectional | RS485 Modbus | IP51 | DIN | Carlo Gavazzi EM111DINA

    EM111DINA is a modular single-phase energy meter 45 A for direct connection and RS485 Modbus. Suitable for check metering of circuits and premises.

    Published: 2026-11-24 · Data verified against the manufacturer's datasheet: 2026-11-24

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information