Modular surge protector | 4P | 20kA | 275V | II/T2/C | DIN | Promfactor Baltic | MOP4-C275/20 | 4772151000449
Code: MOP4-C275/20Price 46.16 € VAT incl.( 38.15 € VAT excl. )Promfactor Baltic MOP4-C275/20 – a four-pole T2 / Class II surge protective device, designed to protect electrical distribution systems against transient overvoltages. Nominal discharge current – 20 kA, maximum discharge current – 40 kA, maximum continuous operating voltage – 275 V AC, protection level – < 1.8 kV. Mounted on a DIN rail, it has IP20 protection and complies with the IEC/EN 61643-11 standard.
-
Modular surge protective device | 4P | 20kA | 275V | II/T2/C | DIN | Promfactor Baltic | MOP4-C275/20
Promfactor Baltic MOP4-C275/20 – four-pole (4P) modular Class II (T2/C) surge protective device, designed to protect electrical distribution systems against transient overvoltages caused by indirect lightning effects or switching processes in the electrical network. The SPD is intended for systems with a nominal voltage of 230 V AC, while its maximum continuous operating voltage (Uc) is 275 V AC. Nominal discharge current (In) – 20 kA, maximum discharge current (Imax) – 40 kA, with an 8/20 µs current impulse. Voltage protection level (Up) – less than 1.8 kV, while the specified response time is less than 25 ns. The device complies with IEC/EN 61643-11, mounts on a 35 × 7.5 mm DIN rail and has an IP20 thermoplastic enclosure with UL 94 V-0 flammability rating.
Key point:
Transient overvoltages occurring in electrical networks can damage connected electrical and electronic equipment. The Promfactor Baltic MOP4-C275/20 is designed to reduce the effects of such overvoltages by diverting impulse current through the protection circuit and limiting voltage rise in the protected system. The four-pole construction, Class II protection, 20 kA nominal and 40 kA maximum discharge current allow the device to be used in appropriately designed electrical distribution systems. Protection effectiveness depends on correct SPD selection, connection, earthing and coordination with other protective devices.Protection class
II / T2 / CDischarge current
In 20 kA | Imax 40 kAOperating voltage
Uc 275 V ACProtection level
Up < 1.8 kVOperating principle
A surge protective device (SPD) is an electrical protection device intended to limit transient overvoltages in electrical circuits. During normal network operation, it should not significantly affect the power supply of connected electrical appliances. When an overvoltage impulse occurs, the SPD reduces the voltage rise and provides a path for the impulse current to be diverted through the protection circuit.
Class II (T2/C) protection is intended to protect electrical installations against transient overvoltages. Such overvoltages may occur due to switching processes in the electrical network or indirect lightning effects. A T2 SPD is not automatically equivalent to a T1 SPD designed to handle part of the direct lightning current discharge load.
Nominal discharge current In = 20 kA describes the standardised 8/20 µs impulse current value used to evaluate the discharge characteristics of the SPD. Maximum discharge current Imax = 40 kA indicates the highest declared impulse discharge current of the same waveform. These parameters must not be interpreted as normal continuous load current.
Uc = 275 V AC is the maximum continuous operating voltage that the SPD is intended to withstand across its terminals under normal operating conditions. The nominal electrical system voltage (Uo) is 230 V AC. Correct Uc selection depends on the electrical network system and the connection arrangement used.
Protection level Up < 1.8 kV describes the voltage-limiting characteristic of the SPD at nominal discharge current. It is not an absolute guarantee that the voltage at the terminals of the protected device will remain below this value during every overvoltage event. The actual protection level is influenced by connection lead length, lead routing, earthing and the overall electrical installation design.
The specified response time is less than 25 ns. This parameter describes the fast reaction of the SPD to a transient overvoltage, but overall protection effectiveness also depends on the electrical characteristics of the device and the installation conditions.
The device's four-pole construction (4P) is intended for appropriate multi-pole surge protection arrangements. In three-phase systems, the specific protection topology for phase and neutral conductors must be selected according to the network earthing system and the original SPD wiring diagram.
The SPD is mounted on a standard 35 × 7.5 mm DIN rail in an electrical distribution board. Correct operation requires proper connection, correct arrangement of protective conductors and, where required, suitable additional overcurrent protection.
Why is this surge protective device useful?
The MOP4-C275/20 helps reduce the effects of transient overvoltages on the electrical distribution network and connected equipment. A nominal discharge current of 20 kA, maximum discharge current of 40 kA, protection level below 1.8 kV and fast response allow the device to be used in a Class II surge protection system. The compact modular construction and DIN-rail mounting simplify integration into an electrical distribution board.Technical specifications
Manufacturer / brand Promfactor Baltic Model MOP4-C275/20 EAN code 4772151000449 Product type Modular surge protective device (SPD) Protection class II / T2 / C Standard IEC/EN 61643-11 Number of poles 4P (4 poles) Nominal voltage (Uo) 230 V AC Maximum continuous operating voltage (Uc) 275 V AC Nominal frequency 50/60 Hz Nominal discharge current (In) 20 kA (8/20 µs) Maximum discharge current (Imax) 40 kA (8/20 µs) Protection level (Up) < 1.8 kV (at In) Response time (tA) < 25 ns Leakage current at Uc < 0.2 mA Temporary overvoltage (TOV), 5 s 335 V / 5 s (declared withstand) Temporary overvoltage (TOV), 120 min. 440 V / 120 min. (declared withstand) Short-circuit current withstand rating (Isccr) 25 kA / 50 Hz Additional protection when main protective device > 125 A 125 A gG fuse Permissible conductor cross-section Up to 35 mm² Terminal screw tightening torque 3.0 Nm Mounting method DIN rail mounting DIN rail dimensions 35 × 7.5 mm Degree of protection IP20 Enclosure material Thermoplastic Enclosure flammability class UL 94 V-0 Operating temperature −40 °C to +70 °C Storage temperature −25 °C to +70 °C Purpose Protection of electrical distribution systems against transient overvoltages Application areas Residential, commercial and industrial electrical distribution boards Main functions
- Class II / T2 protection – designed to limit transient overvoltages in electrical distribution systems.
- Four-pole construction – used according to the appropriate electrical network connection diagram.
- Nominal discharge current 20 kA – In parameter with an 8/20 µs impulse.
- Maximum discharge current 40 kA – Imax parameter with an 8/20 µs impulse.
- 275 V AC continuous operating voltage – maximum Uc value.
- Protection level below 1.8 kV – Up characteristic at nominal discharge current.
- Fast response – specified response time < 25 ns.
- TOV withstand characteristics – specified values of 335 V / 5 s and 440 V / 120 min.
- Connection of conductors up to 35 mm² – according to terminal design limits.
- 35 × 7.5 mm DIN mounting – intended for standard modular electrical distribution board constructions.
- IP20 enclosure – intended for installation inside a suitable electrical distribution board.
- UL 94 V-0 thermoplastic – enclosure material flammability classification.
- Wide operating temperature range – from −40 °C to +70 °C.
- IEC/EN 61643-11 – product standard applicable to surge protective devices.
Where is it used?
- In residential electrical distribution boards
- In electrical distribution systems of apartment buildings
- In electrical panels of offices and administrative buildings
- In electrical installations of retail and commercial premises
- In electrical systems of hotels and other service buildings
- In electrical distribution boards of factories and industrial equipment
- In electrical installations of warehouses and logistics buildings
- For protection of power supply circuits in automation and control panels
- In electrical power distribution systems of server rooms and IT infrastructure
- In electrical power panels of telecommunications nodes
- In other properly designed Class II surge protection systems
Use according to need
For electrical panel manufacturers (OEM).
Modular 4P surge protective device intended for integration into an electrical distribution board protection system. DIN mounting, 275 V AC Uc and In 20 kA allow the device to be specified in a properly designed panel.For designers / electrical engineers.
II/T2/C class, In 20 kA, Imax 40 kA, Up < 1.8 kV and Isccr 25 kA provide the technical parameters required for SPD selection, taking into account the network system, surge protection coordination and short-circuit conditions.For installers / electricians.
The device is mounted on a 35 × 7.5 mm DIN rail. During connection, it is important to follow the original wiring diagram, use suitable conductors, observe the 3.0 Nm tightening torque and assess the need for additional fuse protection.Practical application
For example, a three-phase electrical distribution board is being designed where Class II protection against transient overvoltages is required. After evaluating the network earthing system, phase and neutral conductor connection arrangement, surge protection coordination and expected short-circuit current, a suitable 4P surge protective device is selected. The MOP4-C275/20 is mounted on a 35 × 7.5 mm DIN rail and connected according to the product wiring diagram. Connection conductors are routed as short and direct as possible, terminals are tightened to 3.0 Nm, and additional protective devices are selected according to the product requirements. In this way, the SPD becomes part of the electrical installation surge protection system.Advantages
- II / T2 / C protection class
- Four-pole construction
- Nominal discharge current In – 20 kA
- Maximum discharge current Imax – 40 kA
- Uc 275 V AC
- Up below 1.8 kV
- Response time below 25 ns
- Isccr 25 kA rating
- DIN rail mounting
- Ability to connect conductors up to 35 mm²
- Operating temperature −40…+70 °C
- UL 94 V-0 thermoplastic enclosure
- Compliance with IEC/EN 61643-11
Limitations
- A T2 SPD does not replace T1 protection where T1 is required
- IP20 enclosure is not suitable for direct exposure to water
- A suitable electrical distribution board construction is required
- Connection depends on the network earthing system
- Connection lead length and routing affect protection performance
- An additional gG fuse may be required
- Permissible conductor cross-section – up to 35 mm²
- Cannot replace circuit breakers or fuses for overload and short-circuit protection
- Not intended to regulate long-term network voltage deviations
- Does not guarantee absolute protection against all overvoltages
Safety and installation notes
- ⚡ Before installing or connecting the SPD, disconnect the power supply and verify the absence of voltage.
- The surge protective device must be installed by a qualified electrical specialist.
- Carry out the connection according to the original product wiring diagram and the electrical network earthing system.
- Before installation, check whether 275 V AC Uc is suitable for the specific network system.
- Assess whether a T1, T2 or coordinated multi-stage surge protection solution is required.
- Do not assign a T1 function to the SPD if this class is not specified.
- Mount the SPD on a properly secured 35 × 7.5 mm DIN rail.
- The electrical distribution board construction must comply with the intended environmental and electrical conditions.
- Select the conductor cross-section according to the electrical installation design and product connection requirements, without exceeding 35 mm².
- Terminal screw tightening torque – 3.0 Nm.
- Install connection conductors as short as possible and without unnecessary loops to reduce additional voltage drop during impulse current flow.
- Ensure correct connection of protective conductors and the earthing system.
- If the rated current of the main protective device exceeds 125 A, an additional 125 A gG fuse is specified for the product.
- Check final overcurrent protection coordination according to the product instructions and design diagram.
- Evaluate the expected short-circuit current and the Isccr 25 kA parameter.
- Install the IP20 SPD inside a suitable protective electrical enclosure protected against water and unsuitable environmental exposure.
- The operating ambient temperature must remain within the range of −40 °C to +70 °C.
- The surge protective device does not replace other electrical installation protection measures.
- After severe overvoltage events or during periodic maintenance, inspect the condition of the device according to the product instructions.
- Always follow the original wiring diagram, applicable electrical installation requirements and project documentation.
Compatibility and protection selection
When selecting the MOP4-C275/20 SPD, the characteristics of the entire electrical installation must be evaluated. Correct operation depends not only on In and Imax parameters, but also on the network earthing system, protection level, short-circuit conditions and connection arrangement.
Parameter What should be checked? Network system Whether the SPD 4P connection topology is suitable for the specific TN, TT or other network system. Protection class Whether T2 protection is sufficient for the installation or whether an additional T1 and/or T3 stage is required. Uc – operating voltage Whether the SPD maximum continuous operating voltage of 275 V AC is suitable for the selected connection arrangement. In and Imax Whether the nominal discharge current of 20 kA and maximum discharge current of 40 kA match the design protection concept. Up – protection level Whether the SPD protection characteristic and actual installation conditions correspond to the surge withstand capability of the protected equipment. Short-circuit current Whether the 25 kA Isccr rating and protective devices are compatible with the short-circuit parameters of the specific distribution board. Connection Conductor cross-section, connection length, routing, terminal tightening and earthing. Additional fuse Whether a 125 A gG fuse is required according to the rating of the main protective device and product requirements. Quick selection guide
4P | T2 / II / CIn 20 kAImax 40 kAUc 275 V ACSuitable when you need:- a four-pole T2 surge protective device;
- Class II electrical installation protection;
- 20 kA nominal discharge current;
- 40 kA maximum discharge current;
- 275 V AC maximum continuous operating voltage;
- modular DIN-rail mounting;
- surge protection for an electrical distribution board.
Check before choosing:- whether the network earthing system is compatible with the SPD connection diagram;
- whether T1, T2 or coordinated protection is required;
- whether 275 V AC Uc matches the network conditions;
- whether the Up < 1.8 kV protection level is suitable for the protected equipment;
- whether the short-circuit parameters are compatible with Isccr 25 kA;
- whether an additional 125 A gG fuse is required;
- whether a suitable DIN rail and conductor connection are provided in the distribution board.
Important reminder: In 20 kA and Imax 40 kA are impulse discharge currents, not permissible continuous load values. A T2 surge protective device does not replace the complete lightning protection system or other electrical protective devices. Proper protection requires a coordinated design solution.FAQ
What is the MOP4-C275/20 surge protective device intended for?
The device is designed to reduce the effects of transient overvoltages on electrical distribution systems and connected equipment. It is used as part of a properly designed surge protection system.What does II / T2 / C mean?
It is a Class II, or Type 2, surge protective device. It is designed to limit transient overvoltages caused by switching processes in the electrical network or indirect lightning effects.What does 4P mean?
4P indicates a four-pole construction. The specific connection arrangement for phase, neutral and protective conductors depends on the electrical network system and product design.Is this SPD intended for a 230 V or 275 V electrical network?
The nominal voltage Uo is 230 V AC, while 275 V AC is the maximum continuous operating voltage Uc. These are different parameters, therefore 275 V must not be treated as the nominal network voltage.What is the difference between In 20 kA and Imax 40 kA?
In 20 kA is the nominal discharge current, while Imax 40 kA is the maximum declared discharge current. Both values are specified for an 8/20 µs current impulse and do not represent continuous operating current.What does protection level Up < 1.8 kV mean?
It is the declared voltage protection level of the SPD at nominal discharge current. The actual voltage at the protected equipment also depends on installation design, connecting conductors and protection coordination.What is the SPD response time?
The declared response time is less than 25 ns.What is the TOV parameter?
TOV (Temporary Overvoltage) describes a temporary overvoltage. For this model, withstand characteristics of 335 V / 5 s and 440 V / 120 min. are specified. These are not normally permissible continuous operating voltages.Does the SPD protect against a direct lightning strike?
This is a T2 SPD intended to limit transient overvoltages. If the electrical installation requires protection against direct lightning current effects, the need for a T1 device or coordinated T1+T2 system must be evaluated.Can it be used in a three-phase electrical system?
The four-pole construction can be used in appropriate three-phase network protection arrangements. Connection suitability must be checked according to the specific TN, TT or other network system and the original product wiring diagram.Can it be used in a single-phase system?
The possibility of using this four-pole SPD in a single-phase system must be evaluated according to the specific product wiring diagram. The 4P designation alone does not confirm compatibility with every single-phase connection configuration.When is an additional 125 A gG fuse required?
It is specified that when the rated current of the main protective device exceeds 125 A, a 125 A gG fuse is required. The final protection arrangement must comply with the product instructions and electrical installation design.What does Isccr 25 kA mean?
Isccr is the short-circuit current withstand rating of the surge protective device, which is important when assessing the suitability of the device for the specific network short-circuit conditions and coordination with protective devices.What conductor cross-sections can be connected?
The permitted conductor cross-section for the terminals is up to 35 mm². The specific cross-section must be selected according to the electrical design and connection requirements.What is the terminal tightening torque?
The specified screw tightening torque is 3.0 Nm.How is the surge protective device mounted?
The device is mounted on a 35 × 7.5 mm DIN rail inside an electrical distribution board. Electrical connection is performed according to the product wiring diagram.Is the device water-resistant?
No. IP20 does not provide protection against water, therefore the SPD must be installed inside a suitable electrical enclosure.What does UL 94 V-0 mean?
UL 94 V-0 is a thermoplastic flammability classification describing material behaviour under specified flame test conditions. It does not mean that the material is absolutely non-combustible.What temperature range does the SPD operate in?
Operating temperature – from −40 °C to +70 °C. Storage temperature – from −25 °C to +70 °C.Does the SPD replace a circuit breaker?
No. The surge protective device is intended for protection against transient overvoltages, while circuit breakers and fuses perform overcurrent protection functions.Promfactor Baltic MOP4-C275/20 | 4P surge protective device | T2 | 20/40 kA | 275 V AC
Four-pole Class II (T2/C) modular surge protective device intended to protect electrical distribution systems against transient overvoltages. Nominal discharge current In – 20 kA, maximum Imax – 40 kA (8/20 µs), maximum continuous operating voltage Uc – 275 V AC, protection level Up – below 1.8 kV. Response time < 25 ns, Isccr – 25 kA, operating temperature −40…+70 °C. Mounted on a 35 × 7.5 mm DIN rail, with an IP20 UL 94 V-0 thermoplastic enclosure. Complies with IEC/EN 61643-11. Intended for properly designed surge protection systems in residential, commercial and industrial installations.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products