Products catalog

  • Power distribution terminal | 1P | 135/120 A (Cu/Al) | Cu 2.5–35 mm² / Al 2.5–35 mm² | 1000 V AC | DIN 35 | grey (L) | Promfactor Baltic | FT1035F

    Code: FT1035F
    Barcode: 4772151002757

    Promfactor Baltic FT1035F – 1P terminal 135/120 A, 1000 V AC / 1500 V DC, Cu 2.5–35 / Al 2.5–35 mm², grey (L), DIN rail mounted.

  • Power distribution terminal | 1P | 135/120 A (Cu/Al) | Cu 2.5–35 mm² / Al 2.5–35 mm² | 1000 V AC | DIN 35 | grey (L) | Promfactor Baltic | FT1035F

    FT1035F – a Promfactor Baltic FT series 1P power distribution (connection) terminal for copper and aluminium conductors: Cu 2.5–35 mm², Al 2.5–35 mm², rated current 135 A (Cu) / 120 A (Al), rated voltage 1000 V AC / 1500 V DC. The grey housing is intended for the phase (L) circuit; the terminal is mounted on a 35×7.5 mm DIN rail.

    Key idea:
    The terminal connects and distributes phase conductors in the panel at one clearly marked point. One pole has 2 contacts – the incoming conductor is connected on one side and the outgoing one on the other, and the aluminium alloy clamps accept both Cu and Al conductors.
    Rated current (Cu/Al)
    135 A (Cu) / 120 A (Al)
    Rated voltage
    1000 V AC / 1500 V DC
    Cross-section
    Cu 2.5–35 mm² / Al 2.5–35 mm²
    Poles / colour
    1P (2 contacts), grey – L

    Operating principle

    FT1035F is clipped onto a 35×7.5 mm DIN rail in the distribution board, and the row ends are secured with an EW-35 end stop. The conductor is stripped to the clamp depth; an aluminium conductor is cleaned of oxide and coated with contact paste, then inserted into the clamp and tightened to the torque specified on the product page: 3 Nm (2.5–16 mm²); 6 Nm (25–35 mm²).

    The terminal pole has 2 contacts (2 in total); the aluminium alloy clamps accept 2.5–35 mm² copper and 2.5–35 mm² aluminium conductors. Rated current – 135 A (Cu) / 120 A (Al), rated voltage – 1000 V AC / 1500 V DC, polyamide housing, degree of protection IP20.

    Result – a tidy location for phase connections: the grey housing clearly indicates the circuit function, connections are easy to check and retighten during maintenance, and the control panel is assembled without improvised connections.

    Benefits FT1035F?
    One terminal for Cu and Al wires (2.5–35 mm² Cu / 2.5–35 mm² Al), 135 A (Cu) / 120 A (Al), 1000 V AC / 1500 V DC, L colour coding and 1P design – fewer parts in stock and a clearer control panel layout.

    Technical specifications

    Product type Power distribution (connection) terminal
    Manufacturer / code Promfactor Baltic / FT1035F
    Series FT (1P, 2P, 3P; Cu/Al 1.5–16 … 35–240 mm²; blue, green-yellow, grey)
    Standards IEC/EN 60947-7-1, IEC/EN 61238-1
    Number of poles 1
    Number of contacts 2
    Rated voltage (Un) 1000 V AC / 1500 V DC
    Rated current (In) 135 A (Cu) / 120 A (Al)
    Copper conductors (Cu) 2.5–35 mm²
    Aluminium conductors (Al) 2.5–35 mm²
    Screw tightening torque 3 Nm (2.5–16 mm²); 6 Nm (25–35 mm²)
    Housing material Polyamide PA66
    Clamp material Aluminium alloy
    Degree of protection IP20
    Installation 35×7.5 mm DIN rail
    Operating temperature -25…+55 °C
    Storage temperature -25…+70 °C
    Enclosure colour grey
    Circuit by colour Phase L
    Code structure FT10xx – max. cross-section mm²; N – blue, G – green-yellow, F – grey; no suffix – 1P, 2 – 2P, 3 – 3P

    Main functions

    • Cu and Al conductors – one terminal accepts copper 2.5–35 mm² and aluminium 2.5–35 mm² conductors.
    • Rated current and voltage – 135 A (Cu) / 120 A (Al), 1000 V AC / 1500 V DC – suitable for both AC and DC circuits.
    • Wide cross-section range – from 2.5 to 35 mm² (Cu) – the incoming cable and branches are connected with terminals of the same series.
    • Colour coding – the grey housing immediately identifies the L circuit – fewer errors during installation and maintenance.
    • 1P, 2 contacts – one pole with input and output clamps – a freely configurable row.
    • Screw clamp – tightening torque 3 Nm (2.5–16 mm²); 6 Nm (25–35 mm²) – the connection can be checked and retightened during maintenance.
    • Mounting on a 35×7.5 mm DIN rail – the terminal is placed in a common row with other FT series terminals, and the ends are secured with EW-35.
    • Unified series – the same cross-section is available in blue, green-yellow and grey and in 1P, 2P and 3P versions – N, PE and L connections have the same design.
    • Standards – IEC/EN 60947-7-1, IEC/EN 61238-1 – standards applicable to terminals and Cu/Al connections.

    Where is it used?

    • Detached house incoming panels
    • Supply of stairwell and apartment sub-panels in apartment buildings
    • Office and shop distribution boards
    • AC control panels of solar power plants
    • Supply lines for EV charging stations
    • Connection of aluminium incoming cables up to 35 mm²
    • Temporary construction site control panels

    On-demand operation

    For installers of house incomers and sub-distribution boards.
    The Cu and Al range of 2.5–35 mm² suits incoming and sub-panel supply cables up to 35 mm².
    For installers passing through phase wires.
    The grey housing is intended for phase L conductors, while the blue N and green-yellow PE terminals placed next to it remain visually distinct.
    For designers who prefer a modular row.
    1P terminals are fitted one at a time, so it is easy to build a row with exactly as many poles as needed.

    Practical application

    If a 25 mm² aluminium cable is brought into the incoming panel of a house, then FT1035F (1P, 135 A (Cu) / 120 A (Al), Cu 2.5–35 mm² / Al 2.5–35 mm², grey) is used as the L circuit connection point, and the clamps are tightened to 3–6 Nm according to the conductor cross-section.

    Application guide: how it is used in practice

    FT1035F adapts to different panels – only the cross-section of the connected cable and which conductors are routed onwards change:

    Site What is connected Result Installer's note
    House main incoming control panel Incoming cable L conductor up to 35 mm² The incomer is passed on to the distribution section Strip the Al conductor clean and coat it with contact paste
    Apartment building sub-panel Supply cable 16–25 mm² Sub-distribution board supply without additional connectors Secure the cable so that the terminal is not under tension
    Solar power plant AC control panel Inverter L conductor Tidy inverter connection point Label the wires according to the design
    Terminal row on a DIN rail FT1035F together with FT1035N, FT1035G N, PE and L connections are arranged in a clear order Fit EW-35 at the ends of the row

    How to select an FT series connection terminal

    Cross-section (Cu / Al), poles, colour Recommended model
    Cu 1.5–16 / Al 1.5–16 mm², 1P, blue, 85 A FT1016N (1P, for the N circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 1P, green-yellow, 85 A FT1016G (1P, for the PE circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 1P, grey, 85 A FT1016F (1P, for the L circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 1P, blue, 135/120 A FT1035N (1P, for the N circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 1P, green-yellow, 135/120 A FT1035G (1P, for the PE circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 1P, grey, 135/120 A FT1035F (1P, for the L circuit) ← this model
    Cu 2.5–50 / Al 6–50 mm², 1P, blue, 160/145 A FT1050N (1P, for the N circuit)
    Cu 2.5–50 / Al 6–50 mm², 1P, green-yellow, 160/145 A FT1050G (1P, for the PE circuit)
    Cu 2.5–50 / Al 6–50 mm², 1P, grey, 160/145 A FT1050F (1P, for the L circuit)
    Cu 16–95 / Al 16–95 mm², 1P, blue, 245/220 A FT1095N (1P, for the N circuit)
    Cu 16–95 / Al 16–95 mm², 1P, green-yellow, 245/220 A FT1095G (1P, for the PE circuit)
    Cu 16–95 / Al 16–95 mm², 1P, grey, 245/220 A FT1095F (1P, for the L circuit)
    Cu 35–150 / Al 35–150 mm², 1P, blue FT1150N (1P, for the N circuit)
    Cu 35–150 / Al 35–150 mm², 1P, green-yellow FT1150G (1P, for the PE circuit)
    Cu 35–150 / Al 35–150 mm², 1P, grey FT1150F (1P, for the L circuit)
    Cu 35–240 / Al 35–240 mm², 1P, blue FT1240N (1P, for the N circuit)
    Cu 35–240 / Al 35–240 mm², 1P, green-yellow FT1240G (1P, for the PE circuit)
    Cu 35–240 / Al 35–240 mm², 1P, grey FT1240F (1P, for the L circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 2P, blue, 85 A FT1016N2 (2P, for the N circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 2P, green-yellow, 85 A FT1016G2 (2P, for the PE circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 2P, grey, 85 A FT1016F2 (2P, for the L circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 2P, blue, 135/120 A FT1035N2 (2P, for the N circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 2P, green-yellow, 135/120 A FT1035G2 (2P, for the PE circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 2P, grey, 135/120 A FT1035F2 (2P, for the L circuit)
    Cu 2.5–50 / Al 6–50 mm², 2P, blue, 160/145 A FT1050N2 (2P, for the N circuit)
    Cu 2.5–50 / Al 6–50 mm², 2P, green-yellow, 160/145 A FT1050G2 (2P, for the PE circuit)
    Cu 2.5–50 / Al 6–50 mm², 2P, grey, 160/145 A FT1050F2 (2P, for the L circuit)
    Cu 16–95 / Al 16–95 mm², 2P, blue, 245/220 A FT1095N2 (2P, for the N circuit)
    Cu 16–95 / Al 16–95 mm², 2P, green-yellow, 245/220 A FT1095G2 (2P, for the PE circuit)
    Cu 16–95 / Al 16–95 mm², 2P, grey, 245/220 A FT1095F2 (2P, for the L circuit)
    Cu 35–150 / Al 35–150 mm², 2P, blue FT1150N2 (2P, for the N circuit)
    Cu 35–150 / Al 35–150 mm², 2P, green-yellow FT1150G2 (2P, for the PE circuit)
    Cu 35–150 / Al 35–150 mm², 2P, grey FT1150F2 (2P, for the L circuit)
    Cu 35–240 / Al 35–240 mm², 2P, blue FT1240N2 (2P, for the N circuit)
    Cu 35–240 / Al 35–240 mm², 2P, green-yellow FT1240G2 (2P, for the PE circuit)
    Cu 35–240 / Al 35–240 mm², 2P, grey FT1240F2 (2P, for the L circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 3P, blue, 85 A FT1016N3 (3P, for the N circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 3P, green-yellow, 85 A FT1016G3 (3P, for the PE circuit)
    Cu 1.5–16 / Al 1.5–16 mm², 3P, grey, 85 A FT1016F3 (3P, for the L circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 3P, blue, 135/120 A FT1035N3 (3P, for the N circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 3P, green-yellow, 135/120 A FT1035G3 (3P, for the PE circuit)
    Cu 2.5–35 / Al 2.5–35 mm², 3P, grey, 135/120 A FT1035F3 (3P, for the L circuit)
    Cu 2.5–50 / Al 6–50 mm², 3P, blue, 160/145 A FT1050N3 (3P, for the N circuit)
    Cu 2.5–50 / Al 6–50 mm², 3P, green-yellow, 160/145 A FT1050G3 (3P, for the PE circuit)
    Cu 2.5–50 / Al 6–50 mm², 3P, grey, 160/145 A FT1050F3 (3P, for the L circuit)
    Cu 16–95 / Al 16–95 mm², 3P, blue, 245/220 A FT1095N3 (3P, for the N circuit)
    Cu 16–95 / Al 16–95 mm², 3P, green-yellow, 245/220 A FT1095G3 (3P, for the PE circuit)
    Cu 16–95 / Al 16–95 mm², 3P, grey, 245/220 A FT1095F3 (3P, for the L circuit)
    Cu 35–150 / Al 35–150 mm², 3P, blue FT1150N3 (3P, for the N circuit)
    Cu 35–150 / Al 35–150 mm², 3P, green-yellow FT1150G3 (3P, for the PE circuit)
    Cu 35–150 / Al 35–150 mm², 3P, grey FT1150F3 (3P, for the L circuit)
    Cu 35–240 / Al 35–240 mm², 3P, blue FT1240N3 (3P, for the N circuit)
    Cu 35–240 / Al 35–240 mm², 3P, green-yellow FT1240G3 (3P, for the PE circuit)
    Cu 35–240 / Al 35–240 mm², 3P, grey FT1240F3 (3P, for the L circuit)
    Cu/Al 2.5–35 mm², 3P+N+PE FT503500 (five-pole block for a three-phase line)
    Cu 2.5–50 / Al 6–50 mm², 3P+N+PE FT505000 (five-pole block for a three-phase line)
    Rule: choose the terminal according to the smallest and largest conductor to be connected (Cu and Al ranges differ in FT1050 models), the colour according to the circuit (N – blue, G – green-yellow PE, F – grey for phase L), and the number of poles according to how many separate lines need to be connected; for a three-phase line with N and PE in one block, FT503500 and FT505000 are available.
    When to choose another solution: other colours – FT1035N, FT1035G; other number of poles – FT1035F2, FT1035F3; for thicker cables – FT1050 or FT1095; 3P+N+PE blocks – FT503500, FT505000; distribution terminals DTB080–DTB500; insulated terminals F807–F815; DIN rails FD010100–FD011000; end stop EW-35.

    Pros

    • Rated current 135 A (Cu) / 120 A (Al), voltage 1000 V AC / 1500 V DC
    • Copper 2.5–35 mm² and aluminium 2.5–35 mm² conductors
    • Colour coding of the L circuit (grey)
    • 1P, 2 contacts – freely configurable row
    • Standards IEC/EN 60947-7-1, IEC/EN 61238-1
    • Polyamide PA66 housing, operating temperature -25…+55 °C
    • Mounting on a 35×7.5 mm DIN rail

    Cons / limitations

    • Degree of protection IP20 – install only in closed panels or cabinets
    • Largest conductor – 35 mm²; for thicker cables or higher current choose FT1050 or FT1095
    • Fixed colour – for a different circuit you will need FT1035N, FT1035G
    • Single pole – a three-phase line requires several terminals or the FT503500 / FT505000 block
    • Correct tightening torque and Al conductor preparation (oxide removal, contact paste) are essential

    Safety and installation notes

    • Installation and connection must be carried out only by a qualified electrician after disconnecting the supply and verifying that the circuit is de-energised.
    • Do not exceed the rated current of 135 A (Cu) / 120 A (Al) and the rated voltage of 1000 V AC / 1500 V DC.
    • Tighten the clamps to the specified torque – 3 Nm (2.5–16 mm²); 6 Nm (25–35 mm²) – and check the connections after the first load and during periodic maintenance.
    • The terminal is IP20 – install only in a closed panel or cabinet, operating temperature -25…+55 °C.
    • Use the grey terminal only for the phase (L) circuit; fit an EW-35 end stop at the ends of the row.

    Quick selection guide

    1P
    135/120 A
    1000 V AC / 1500 V DC
    Cu 2.5–35 / Al 2.5–35 mm²
    grey (L)
    DIN 35
    IP20
    Suitable when you need:
    • connect or distribute phase (L) conductors in the control panel;
    • connect copper 2.5–35 mm² and aluminium 2.5–35 mm² conductors up to 135 A (Cu) / 120 A (Al);
    • one pole per conductor, with a freely configurable row.
    Check before use:
    • the smallest and largest conductor to be connected – whether it fits Cu 2.5–35 mm² / Al 2.5–35 mm²;
    • load current – no more than 135 A (Cu) / 120 A (Al);
    • circuit – the grey housing corresponds to L; other circuits will require FT1035N, FT1035G.
    Important reminder: FT1035F – 1P grey terminal for the L circuit; versions in other colours and pole counts, as well as EW-35, are ordered separately.

    FAQ

    What does the letter F mean in the code FT1035F?
    The letter F denotes a grey housing for the L circuit; in the FT series, N stands for the blue, G for the green-yellow and F for the grey version.
    What wire cross-sections can be connected?
    Copper 2.5–35 mm² and aluminium 2.5–35 mm² conductors; Al conductors must be cleaned of oxide and coated with contact paste before connection.
    How many poles and contacts does FT1035F have?
    FT1035F is a 1P terminal with 2 contacts (2 per pole); in the FT series, a code without a suffix means 1P, suffix 2 – 2P, suffix 3 – 3P.
    What are the rated current and voltage?
    Rated current 135 A (Cu) / 120 A (Al), rated voltage 1000 V AC / 1500 V DC.
    What tightening torque should be used for the screws?
    Depending on the conductor cross-section: 3 Nm (2.5–16 mm²); 6 Nm (25–35 mm²).
    How is the terminal installed?
    The terminal is clipped onto a 35×7.5 mm DIN rail, and an EW-35 end stop is fitted at the ends of the row.

    Power distribution terminal | 1P | 135/120 A (Cu/Al) | Cu 2.5–35 mm² / Al 2.5–35 mm² | 1000 V AC | DIN 35 | grey (L) | Promfactor Baltic | FT1035F

    Promfactor Baltic FT1035F – 1P power distribution terminal 135 A (Cu) / 120 A (Al), 1000 V AC / 1500 V DC, for copper 2.5–35 mm² and aluminium 2.5–35 mm² wires, grey housing for the L circuit, IP20, DIN rail mounting, IEC/EN 60947-7-1, IEC/EN 61238-1.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Aluminium power cable | 4x50mm² | AXMK | Class 2 | 1500m | Black
    Code: SKU#165996533759726861

    Aluminium power cable AXMK 4×50 mm², designed for fixed 0.6/1 kV power transmission and distribution installations. The cable features Class 2 aluminium conductors, XLPE insulation and a black UV-resistant PVC sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits and concrete. Maximum operating temperature – 90 °C.  

    Sold by the drum, i.e. the minimum order quantity is 1500 metres.

    Delivery time: up to 6 weeks. 

    Price 6.32 € VAT incl.
    ( 5.22 € VAT excl. )
    Terminal | connector paste for contacts | reduces oxidation | 35.3g | WAGO | ALU PLUS | 249-130 | for connecting aluminium and copper wires
    Code: 4017332133890

    Contact paste designed to protect aluminum conductors from oxidation and ensure a reliable electrical connection. This special paste allows aluminum and copper conductors to be safely and efficiently connected within the same connector, making it particularly useful when renovating older electrical installations where aluminum wiring is commonly found.

    Aluminum naturally oxidizes, and the resulting oxide layer increases contact resistance, causes connection heating, and may become a source of electrical faults. By using WAGO ALU-PLUS, the oxidation layer is reduced, electrical conductivity is improved, and the service life of the connection is significantly extended. 

    Price 2.83 € VAT incl.
    ( 2.34 € VAT excl. )