Power distribution terminal | 1P | 160/145 A (Cu/Al) | Cu 2.5–50 mm² / Al 6–50 mm² | 1000 V AC | DIN 35 | blue (N) | Promfactor Baltic | FT1050N
Code: FT1050NPrice 2.00 € VAT incl.( 1.65 € VAT excl. )Promfactor Baltic FT1050N – 1P terminal 160/145 A, 1000 V AC / 1500 V DC, Cu 2.5–50 / Al 6–50 mm², blue (N), DIN rail mounted.
-
Power distribution terminal | 1P | 160/145 A (Cu/Al) | Cu 2.5–50 mm² / Al 6–50 mm² | 1000 V AC | DIN 35 | blue (N) | Promfactor Baltic | FT1050N
FT1050N – a Promfactor Baltic FT series 1P power distribution (connection) terminal for copper and aluminium conductors: Cu 2.5–50 mm², Al 6–50 mm², rated current 160 A (Cu) / 145 A (Al), rated voltage 1000 V AC / 1500 V DC. The blue housing is intended for the neutral (N) circuit; the terminal is mounted on a 35×7.5 mm DIN rail.
Key idea:
The terminal connects and distributes neutral conductors in the panel at one clearly marked point. One pole has 2 contacts – the incoming conductor is connected on one side and the outgoing one on the other, and the aluminium alloy clamps accept both Cu and Al conductors.Rated current (Cu/Al)
160 A (Cu) / 145 A (Al)Rated voltage
1000 V AC / 1500 V DCCross-section
Cu 2.5–50 mm² / Al 6–50 mm²Poles / colour
1P (2 contacts), blue – NOperating principle
FT1050N is clipped onto a 35×7.5 mm DIN rail in the distribution board, and the row ends are secured with an EW-35 end stop. The conductor is stripped to the clamp depth; an aluminium conductor is cleaned of oxide and coated with contact paste, then inserted into the clamp and tightened to the torque specified on the product page: 4 Nm (2.5–4 mm²); 12 Nm (6–50 mm²).
The terminal pole has 2 contacts (2 in total); the aluminium alloy clamps accept 2.5–50 mm² copper and 6–50 mm² aluminium conductors. Rated current – 160 A (Cu) / 145 A (Al), rated voltage – 1000 V AC / 1500 V DC, polyamide housing, degree of protection IP20.
Result – a tidy location for neutral connections: the blue housing clearly indicates the circuit function, connections are easy to check and retighten during maintenance, and the control panel is assembled without improvised connections.
Benefits FT1050N?
One terminal for Cu and Al wires (2.5–50 mm² Cu / 6–50 mm² Al), 160 A (Cu) / 145 A (Al), 1000 V AC / 1500 V DC, N colour coding and 1P design – fewer parts in stock and a clearer control panel layout.Technical specifications
Product type Power distribution (connection) terminal Manufacturer / code Promfactor Baltic / FT1050N Series FT (1P, 2P, 3P; Cu/Al 1.5–16 … 35–240 mm²; blue, green-yellow, grey) Standards IEC/EN 60947-7-1, IEC/EN 61238-1 Number of poles 1 Number of contacts 2 Rated voltage (Un) 1000 V AC / 1500 V DC Rated current (In) 160 A (Cu) / 145 A (Al) Copper conductors (Cu) 2.5–50 mm² Aluminium conductors (Al) 6–50 mm² Screw tightening torque 4 Nm (2.5–4 mm²); 12 Nm (6–50 mm²) Housing material Polyamide PA66 Clamp material Aluminium alloy Degree of protection IP20 Installation 35×7.5 mm DIN rail Operating temperature -25…+55 °C Storage temperature -25…+70 °C Weight 35 g Enclosure colour blue Circuit by colour Neutral N Code structure FT10xx – max. cross-section mm²; N – blue, G – green-yellow, F – grey; no suffix – 1P, 2 – 2P, 3 – 3P Main functions
- Cu and Al conductors – one terminal accepts copper 2.5–50 mm² and aluminium 6–50 mm² conductors.
- Rated current and voltage – 160 A (Cu) / 145 A (Al), 1000 V AC / 1500 V DC – suitable for both AC and DC circuits.
- Wide cross-section range – from 2.5 to 50 mm² (Cu) – the incoming cable and branches are connected with terminals of the same series.
- Colour coding – the blue housing immediately identifies the N circuit – fewer errors during installation and maintenance.
- 1P, 2 contacts – one pole with input and output clamps – a freely configurable row.
- Screw clamp – tightening torque 4 Nm (2.5–4 mm²); 12 Nm (6–50 mm²) – the connection can be checked and retightened during maintenance.
- Mounting on a 35×7.5 mm DIN rail – the terminal is placed in a common row with other FT series terminals, and the ends are secured with EW-35.
- Unified series – the same cross-section is available in blue, green-yellow and grey and in 1P, 2P and 3P versions – N, PE and L connections have the same design.
- Standards – IEC/EN 60947-7-1, IEC/EN 61238-1 – standards applicable to terminals and Cu/Al connections.
Where is it used?
- Incoming control panels with aluminium supply cables
- Distribution boards in commercial premises
- Production workshop sub-panels
- AC side of solar power plants and inverters
- Supply control panels of agricultural buildings
- Supply for a group of several EV chargers
- Renovated sites where old aluminium cables are being replaced
On-demand operation
For contractors connecting aluminium supply cables.
Al conductors from 6 to 50 mm² and copper ones from 2.5 to 50 mm² are accepted, so it suits both aluminium and copper cables.For control panel assemblers forming an N busbar.
The blue housing immediately identifies the neutral circuit, so N connections in the control panel are recognisable without additional markers.For designers who prefer a modular row.
1P terminals are fitted one at a time, so it is easy to build a row with exactly as many poles as needed.Practical application
If a 50 mm² aluminium supply cable is brought into a commercial premises panel, then FT1050N (1P, 160 A (Cu) / 145 A (Al), Cu 2.5–50 mm² / Al 6–50 mm², blue) is used as the N circuit connection point, and the clamps are tightened to 4–12 Nm according to the conductor cross-section.Application guide: how it is used in practice
FT1050N adapts to different panels – only the cross-section of the connected cable and which conductors are routed onwards change:
Site What is connected Result Installer's note Incomer with Al cable Aluminium N conductor 6–50 mm² Al cable is connected in the panel Strip the Al conductor clean and coat it with contact paste Workshop sub-panel Copper supply cable up to 50 mm² Sub-distribution board supply Check the tightening during periodic maintenance Charging station group Circuit supply N conductor Distribution to several stations Circuit current must not exceed 160 A (Cu) / 145 A (Al) Terminal row on a DIN rail FT1050N together with FT1050G, FT1050F N, PE and L connections are arranged in a clear order Fit EW-35 at the ends of the row How to select an FT series connection terminal
Cross-section (Cu / Al), poles, colour Recommended model Cu 1.5–16 / Al 1.5–16 mm², 1P, blue, 85 A FT1016N (1P, for the N circuit) Cu 1.5–16 / Al 1.5–16 mm², 1P, green-yellow, 85 A FT1016G (1P, for the PE circuit) Cu 1.5–16 / Al 1.5–16 mm², 1P, grey, 85 A FT1016F (1P, for the L circuit) Cu 2.5–35 / Al 2.5–35 mm², 1P, blue, 135/120 A FT1035N (1P, for the N circuit) Cu 2.5–35 / Al 2.5–35 mm², 1P, green-yellow, 135/120 A FT1035G (1P, for the PE circuit) Cu 2.5–35 / Al 2.5–35 mm², 1P, grey, 135/120 A FT1035F (1P, for the L circuit) Cu 2.5–50 / Al 6–50 mm², 1P, blue, 160/145 A FT1050N (1P, for the N circuit) ← this model Cu 2.5–50 / Al 6–50 mm², 1P, green-yellow, 160/145 A FT1050G (1P, for the PE circuit) Cu 2.5–50 / Al 6–50 mm², 1P, grey, 160/145 A FT1050F (1P, for the L circuit) Cu 16–95 / Al 16–95 mm², 1P, blue, 245/220 A FT1095N (1P, for the N circuit) Cu 16–95 / Al 16–95 mm², 1P, green-yellow, 245/220 A FT1095G (1P, for the PE circuit) Cu 16–95 / Al 16–95 mm², 1P, grey, 245/220 A FT1095F (1P, for the L circuit) Cu 35–150 / Al 35–150 mm², 1P, blue FT1150N (1P, for the N circuit) Cu 35–150 / Al 35–150 mm², 1P, green-yellow FT1150G (1P, for the PE circuit) Cu 35–150 / Al 35–150 mm², 1P, grey FT1150F (1P, for the L circuit) Cu 35–240 / Al 35–240 mm², 1P, blue FT1240N (1P, for the N circuit) Cu 35–240 / Al 35–240 mm², 1P, green-yellow FT1240G (1P, for the PE circuit) Cu 35–240 / Al 35–240 mm², 1P, grey FT1240F (1P, for the L circuit) Cu 1.5–16 / Al 1.5–16 mm², 2P, blue, 85 A FT1016N2 (2P, for the N circuit) Cu 1.5–16 / Al 1.5–16 mm², 2P, green-yellow, 85 A FT1016G2 (2P, for the PE circuit) Cu 1.5–16 / Al 1.5–16 mm², 2P, grey, 85 A FT1016F2 (2P, for the L circuit) Cu 2.5–35 / Al 2.5–35 mm², 2P, blue, 135/120 A FT1035N2 (2P, for the N circuit) Cu 2.5–35 / Al 2.5–35 mm², 2P, green-yellow, 135/120 A FT1035G2 (2P, for the PE circuit) Cu 2.5–35 / Al 2.5–35 mm², 2P, grey, 135/120 A FT1035F2 (2P, for the L circuit) Cu 2.5–50 / Al 6–50 mm², 2P, blue, 160/145 A FT1050N2 (2P, for the N circuit) Cu 2.5–50 / Al 6–50 mm², 2P, green-yellow, 160/145 A FT1050G2 (2P, for the PE circuit) Cu 2.5–50 / Al 6–50 mm², 2P, grey, 160/145 A FT1050F2 (2P, for the L circuit) Cu 16–95 / Al 16–95 mm², 2P, blue, 245/220 A FT1095N2 (2P, for the N circuit) Cu 16–95 / Al 16–95 mm², 2P, green-yellow, 245/220 A FT1095G2 (2P, for the PE circuit) Cu 16–95 / Al 16–95 mm², 2P, grey, 245/220 A FT1095F2 (2P, for the L circuit) Cu 35–150 / Al 35–150 mm², 2P, blue FT1150N2 (2P, for the N circuit) Cu 35–150 / Al 35–150 mm², 2P, green-yellow FT1150G2 (2P, for the PE circuit) Cu 35–150 / Al 35–150 mm², 2P, grey FT1150F2 (2P, for the L circuit) Cu 35–240 / Al 35–240 mm², 2P, blue FT1240N2 (2P, for the N circuit) Cu 35–240 / Al 35–240 mm², 2P, green-yellow FT1240G2 (2P, for the PE circuit) Cu 35–240 / Al 35–240 mm², 2P, grey FT1240F2 (2P, for the L circuit) Cu 1.5–16 / Al 1.5–16 mm², 3P, blue, 85 A FT1016N3 (3P, for the N circuit) Cu 1.5–16 / Al 1.5–16 mm², 3P, green-yellow, 85 A FT1016G3 (3P, for the PE circuit) Cu 1.5–16 / Al 1.5–16 mm², 3P, grey, 85 A FT1016F3 (3P, for the L circuit) Cu 2.5–35 / Al 2.5–35 mm², 3P, blue, 135/120 A FT1035N3 (3P, for the N circuit) Cu 2.5–35 / Al 2.5–35 mm², 3P, green-yellow, 135/120 A FT1035G3 (3P, for the PE circuit) Cu 2.5–35 / Al 2.5–35 mm², 3P, grey, 135/120 A FT1035F3 (3P, for the L circuit) Cu 2.5–50 / Al 6–50 mm², 3P, blue, 160/145 A FT1050N3 (3P, for the N circuit) Cu 2.5–50 / Al 6–50 mm², 3P, green-yellow, 160/145 A FT1050G3 (3P, for the PE circuit) Cu 2.5–50 / Al 6–50 mm², 3P, grey, 160/145 A FT1050F3 (3P, for the L circuit) Cu 16–95 / Al 16–95 mm², 3P, blue, 245/220 A FT1095N3 (3P, for the N circuit) Cu 16–95 / Al 16–95 mm², 3P, green-yellow, 245/220 A FT1095G3 (3P, for the PE circuit) Cu 16–95 / Al 16–95 mm², 3P, grey, 245/220 A FT1095F3 (3P, for the L circuit) Cu 35–150 / Al 35–150 mm², 3P, blue FT1150N3 (3P, for the N circuit) Cu 35–150 / Al 35–150 mm², 3P, green-yellow FT1150G3 (3P, for the PE circuit) Cu 35–150 / Al 35–150 mm², 3P, grey FT1150F3 (3P, for the L circuit) Cu 35–240 / Al 35–240 mm², 3P, blue FT1240N3 (3P, for the N circuit) Cu 35–240 / Al 35–240 mm², 3P, green-yellow FT1240G3 (3P, for the PE circuit) Cu 35–240 / Al 35–240 mm², 3P, grey FT1240F3 (3P, for the L circuit) Cu/Al 2.5–35 mm², 3P+N+PE FT503500 (five-pole block for a three-phase line) Cu 2.5–50 / Al 6–50 mm², 3P+N+PE FT505000 (five-pole block for a three-phase line) Rule: choose the terminal according to the smallest and largest conductor to be connected (Cu and Al ranges differ in FT1050 models), the colour according to the circuit (N – blue, G – green-yellow PE, F – grey for phase L), and the number of poles according to how many separate lines need to be connected; for a three-phase line with N and PE in one block, FT503500 and FT505000 are available.When to choose another solution: other colours – FT1050G, FT1050F; other number of poles – FT1050N2, FT1050N3; for thicker cables – FT1095; 3P+N+PE blocks – FT503500, FT505000; distribution terminals DTB080–DTB500; insulated terminals F807–F815; DIN rails FD010100–FD011000; end stop EW-35.Pros
- Rated current 160 A (Cu) / 145 A (Al), voltage 1000 V AC / 1500 V DC
- Copper 2.5–50 mm² and aluminium 6–50 mm² conductors
- Colour coding of the N circuit (blue)
- 1P, 2 contacts – freely configurable row
- Standards IEC/EN 60947-7-1, IEC/EN 61238-1
- Polyamide PA66 housing, operating temperature -25…+55 °C
- Mounting on a 35×7.5 mm DIN rail
Cons / limitations
- Degree of protection IP20 – install only in closed panels or cabinets
- Aluminium conductors only from 6 mm²; for higher current or thicker cables choose FT1095
- Fixed colour – for a different circuit you will need FT1050G, FT1050F
- Single pole – a three-phase line requires several terminals or the FT503500 / FT505000 block
- Correct tightening torque and Al conductor preparation (oxide removal, contact paste) are essential
Safety and installation notes
- Installation and connection must be carried out only by a qualified electrician after disconnecting the supply and verifying that the circuit is de-energised.
- Do not exceed the rated current of 160 A (Cu) / 145 A (Al) and the rated voltage of 1000 V AC / 1500 V DC.
- Tighten the clamps to the specified torque – 4 Nm (2.5–4 mm²); 12 Nm (6–50 mm²) – and check the connections after the first load and during periodic maintenance.
- The terminal is IP20 – install only in a closed panel or cabinet, operating temperature -25…+55 °C.
- Use the blue terminal only for the neutral (N) circuit; fit an EW-35 end stop at the ends of the row.
Quick selection guide
1P160/145 A1000 V AC / 1500 V DCCu 2.5–50 / Al 6–50 mm²blue (N)DIN 35IP20Suitable when you need:- connect or distribute neutral (N) conductors in the control panel;
- connect copper 2.5–50 mm² and aluminium 6–50 mm² conductors up to 160 A (Cu) / 145 A (Al);
- one pole per conductor, with a freely configurable row.
Check before use:- the smallest and largest conductor to be connected – whether it fits Cu 2.5–50 mm² / Al 6–50 mm²;
- load current – no more than 160 A (Cu) / 145 A (Al);
- circuit – the blue housing corresponds to N; other circuits will require FT1050G, FT1050F.
Important reminder: FT1050N – 1P blue terminal for the N circuit; versions in other colours and pole counts, as well as EW-35, are ordered separately.FAQ
What does the letter N mean in the code FT1050N?
The letter N denotes a blue housing for the N circuit; in the FT series, N stands for the blue, G for the green-yellow and F for the grey version.What wire cross-sections can be connected?
Copper 2.5–50 mm² and aluminium 6–50 mm² conductors; Al conductors must be cleaned of oxide and coated with contact paste before connection.How many poles and contacts does FT1050N have?
FT1050N is a 1P terminal with 2 contacts (2 per pole); in the FT series, a code without a suffix means 1P, suffix 2 – 2P, suffix 3 – 3P.What are the rated current and voltage?
Rated current 160 A (Cu) / 145 A (Al), rated voltage 1000 V AC / 1500 V DC.What tightening torque should be used for the screws?
Depending on the conductor cross-section: 4 Nm (2.5–4 mm²); 12 Nm (6–50 mm²).How is the terminal installed?
The terminal is clipped onto a 35×7.5 mm DIN rail, and an EW-35 end stop is fitted at the ends of the row.Power distribution terminal | 1P | 160/145 A (Cu/Al) | Cu 2.5–50 mm² / Al 6–50 mm² | 1000 V AC | DIN 35 | blue (N) | Promfactor Baltic | FT1050N
Promfactor Baltic FT1050N – 1P power distribution terminal 160 A (Cu) / 145 A (Al), 1000 V AC / 1500 V DC, for copper 2.5–50 mm² and aluminium 6–50 mm² wires, blue housing for the N circuit, IP20, DIN rail mounting, IEC/EN 60947-7-1, IEC/EN 61238-1.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Terminal | connector paste for contacts | reduces oxidation | 35.3g | WAGO | ALU PLUS | 249-130 | for connecting aluminium and copper wiresCode: 4017332133890Contact paste designed to protect aluminum conductors from oxidation and ensure a reliable electrical connection. This special paste allows aluminum and copper conductors to be safely and efficiently connected within the same connector, making it particularly useful when renovating older electrical installations where aluminum wiring is commonly found.
Aluminum naturally oxidizes, and the resulting oxide layer increases contact resistance, causes connection heating, and may become a source of electrical faults. By using WAGO ALU-PLUS, the oxidation layer is reduced, electrical conductivity is improved, and the service life of the connection is significantly extended.
Price 2.83 € VAT incl.( 2.34 € VAT excl. )Aluminium power cable | 4x50mm² | AXMK | Class 2 | 1500m | BlackCode: SKU#165996533759726861Aluminium power cable AXMK 4×50 mm², designed for fixed 0.6/1 kV power transmission and distribution installations. The cable features Class 2 aluminium conductors, XLPE insulation and a black UV-resistant PVC sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits and concrete. Maximum operating temperature – 90 °C.
Sold by the drum, i.e. the minimum order quantity is 1500 metres.
Delivery time: up to 6 weeks.
Price 6.32 € VAT incl.( 5.22 € VAT excl. )