Power distribution terminal | 2P | 245/220 A (Cu/Al) | Cu 16–95 mm² / Al 16–95 mm² | 1000 V AC | DIN 35 | blue (N) | Promfactor Baltic | FT1095N2
Code: FT1095N2Price 8.39 € VAT incl.( 6.93 € VAT excl. )Promfactor Baltic FT1095N2 – 2P terminal 245/220 A, 1000 V AC / 1500 V DC, Cu 16–95 / Al 16–95 mm², blue (N), DIN rail mounted.
-
Power distribution terminal | 2P | 245/220 A (Cu/Al) | Cu 16–95 mm² / Al 16–95 mm² | 1000 V AC | DIN 35 | blue (N) | Promfactor Baltic | FT1095N2
FT1095N2 – a Promfactor Baltic FT series 2P power distribution (connection) terminal for copper and aluminium conductors: Cu 16–95 mm², Al 16–95 mm², rated current 245 A (Cu) / 220 A (Al), rated voltage 1000 V AC / 1500 V DC. The blue housing is intended for the neutral (N) circuit; the terminal is mounted on a 35×7.5 mm DIN rail.
Key idea:
The terminal connects and distributes neutral conductors in the panel at one clearly marked point. 2 poles have 2 contacts each (4 in total) – the incoming conductor is connected on one side and the outgoing one on the other, and the aluminium alloy clamps accept both Cu and Al conductors.Rated current (Cu/Al)
245 A (Cu) / 220 A (Al)Rated voltage
1000 V AC / 1500 V DCCross-section
Cu 16–95 mm² / Al 16–95 mm²Poles / colour
2P (4 contacts), blue – NOperating principle
FT1095N2 is clipped onto a 35×7.5 mm DIN rail in the distribution board, and the row ends are secured with an EW-35 end stop. The conductor is stripped to the clamp depth; an aluminium conductor is cleaned of oxide and coated with contact paste, then inserted into the clamp and tightened to the torque specified on the product page: 20 Nm (16–95 mm²).
Each of the 2 poles has 2 contacts (4 in total); the aluminium alloy clamps accept 16–95 mm² copper and 16–95 mm² aluminium conductors. Rated current – 245 A (Cu) / 220 A (Al), rated voltage – 1000 V AC / 1500 V DC, polyamide housing, degree of protection IP20.
Result – a tidy location for neutral connections: the blue housing clearly indicates the circuit function, connections are easy to check and retighten during maintenance, and the control panel is assembled without improvised connections.
Benefits FT1095N2?
One terminal for Cu and Al wires (16–95 mm² Cu / 16–95 mm² Al), 245 A (Cu) / 220 A (Al), 1000 V AC / 1500 V DC, N colour coding and 2P design – fewer parts in stock and a clearer control panel layout.Technical specifications
Product type Power distribution (connection) terminal Manufacturer / code Promfactor Baltic / FT1095N2 Series FT (1P, 2P, 3P; Cu/Al 1.5–16 … 35–240 mm²; blue, green-yellow, grey) Standards IEC/EN 60947-7-1, IEC/EN 61238-1 Number of poles 2 Number of contacts 4 Rated voltage (Un) 1000 V AC / 1500 V DC Rated current (In) 245 A (Cu) / 220 A (Al) Copper conductors (Cu) 16–95 mm² Aluminium conductors (Al) 16–95 mm² Screw tightening torque 20 Nm (16–95 mm²) Housing material Polyamide PA66 Clamp material Aluminium alloy Degree of protection IP20 Installation 35×7.5 mm DIN rail Operating temperature -25…+55 °C Storage temperature -25…+70 °C Weight 165 g Enclosure colour blue Circuit by colour Neutral N Code structure FT10xx – max. cross-section mm²; N – blue, G – green-yellow, F – grey; no suffix – 1P, 2 – 2P, 3 – 3P Main functions
- Cu and Al conductors – one terminal accepts copper 16–95 mm² and aluminium 16–95 mm² conductors.
- Rated current and voltage – 245 A (Cu) / 220 A (Al), 1000 V AC / 1500 V DC – suitable for both AC and DC circuits.
- Wide cross-section range – from 16 to 95 mm² (Cu) – the incoming cable and branches are connected with terminals of the same series.
- Colour coding – the blue housing immediately identifies the N circuit – fewer errors during installation and maintenance.
- 2P, 4 contacts – 2 poles with 2 contacts each in one product – faster installation and fewer parts on the rail.
- Screw clamp – tightening torque 20 Nm (16–95 mm²) – the connection can be checked and retightened during maintenance.
- Mounting on a 35×7.5 mm DIN rail – the terminal is placed in a common row with other FT series terminals, and the ends are secured with EW-35.
- Unified series – the same cross-section is available in blue, green-yellow and grey and in 1P, 2P and 3P versions – N, PE and L connections have the same design.
- Standards – IEC/EN 60947-7-1, IEC/EN 61238-1 – standards applicable to terminals and Cu/Al connections.
Where is it used?
- Building incoming and metering control panels
- Industrial distribution boards
- Main cable branches
- AC panels of larger solar power plants
- Production line supply panels
- Supply for EV charging parks
- Connection of 16–95 mm² aluminium cables
On-demand operation
For assemblers of industrial and commercial control panels.
The Cu and Al range of 16–95 mm² is intended for main and incoming cables, and the smallest connectable conductor is 16 mm².For control panel assemblers forming an N busbar.
The blue housing immediately identifies the neutral circuit, so N connections in the control panel are recognisable without additional markers.For the electrician connecting two separate lines.
The 2P block has two poles in one product, so fewer separate parts are mounted on the rail.Practical application
If a 95 mm² aluminium cable is used at the incomer of an industrial panel, then FT1095N2 (2P, 245 A (Cu) / 220 A (Al), Cu 16–95 mm² / Al 16–95 mm², blue) is used as the N circuit connection point, and the clamps are tightened to 20 Nm according to the conductor cross-section.Application guide: how it is used in practice
FT1095N2 adapts to different panels – only the cross-section of the connected cable and which conductors are routed onwards change:
Site What is connected Result Installer's note Building main incoming control panel Incoming N conductor up to 95 mm² The incomer is connected to the distribution section Minimum conductor – 16 mm² Industrial distribution board Main cable 50–95 mm² Branches to sub-panels Secure the cable so that its weight does not load the terminal Aluminium cable connection Al N conductor 16–95 mm² Al cable is connected without additional adapters Strip the Al conductor clean and coat it with contact paste Terminal row on a DIN rail FT1095N2 together with FT1095G2, FT1095F2 N, PE and L connections are arranged in a clear order Fit EW-35 at the ends of the row How to select an FT series connection terminal
Cross-section (Cu / Al), poles, colour Recommended model Cu 1.5–16 / Al 1.5–16 mm², 1P, blue, 85 A FT1016N (1P, for the N circuit) Cu 1.5–16 / Al 1.5–16 mm², 1P, green-yellow, 85 A FT1016G (1P, for the PE circuit) Cu 1.5–16 / Al 1.5–16 mm², 1P, grey, 85 A FT1016F (1P, for the L circuit) Cu 2.5–35 / Al 2.5–35 mm², 1P, blue, 135/120 A FT1035N (1P, for the N circuit) Cu 2.5–35 / Al 2.5–35 mm², 1P, green-yellow, 135/120 A FT1035G (1P, for the PE circuit) Cu 2.5–35 / Al 2.5–35 mm², 1P, grey, 135/120 A FT1035F (1P, for the L circuit) Cu 2.5–50 / Al 6–50 mm², 1P, blue, 160/145 A FT1050N (1P, for the N circuit) Cu 2.5–50 / Al 6–50 mm², 1P, green-yellow, 160/145 A FT1050G (1P, for the PE circuit) Cu 2.5–50 / Al 6–50 mm², 1P, grey, 160/145 A FT1050F (1P, for the L circuit) Cu 16–95 / Al 16–95 mm², 1P, blue, 245/220 A FT1095N (1P, for the N circuit) Cu 16–95 / Al 16–95 mm², 1P, green-yellow, 245/220 A FT1095G (1P, for the PE circuit) Cu 16–95 / Al 16–95 mm², 1P, grey, 245/220 A FT1095F (1P, for the L circuit) Cu 35–150 / Al 35–150 mm², 1P, blue FT1150N (1P, for the N circuit) Cu 35–150 / Al 35–150 mm², 1P, green-yellow FT1150G (1P, for the PE circuit) Cu 35–150 / Al 35–150 mm², 1P, grey FT1150F (1P, for the L circuit) Cu 35–240 / Al 35–240 mm², 1P, blue FT1240N (1P, for the N circuit) Cu 35–240 / Al 35–240 mm², 1P, green-yellow FT1240G (1P, for the PE circuit) Cu 35–240 / Al 35–240 mm², 1P, grey FT1240F (1P, for the L circuit) Cu 1.5–16 / Al 1.5–16 mm², 2P, blue, 85 A FT1016N2 (2P, for the N circuit) Cu 1.5–16 / Al 1.5–16 mm², 2P, green-yellow, 85 A FT1016G2 (2P, for the PE circuit) Cu 1.5–16 / Al 1.5–16 mm², 2P, grey, 85 A FT1016F2 (2P, for the L circuit) Cu 2.5–35 / Al 2.5–35 mm², 2P, blue, 135/120 A FT1035N2 (2P, for the N circuit) Cu 2.5–35 / Al 2.5–35 mm², 2P, green-yellow, 135/120 A FT1035G2 (2P, for the PE circuit) Cu 2.5–35 / Al 2.5–35 mm², 2P, grey, 135/120 A FT1035F2 (2P, for the L circuit) Cu 2.5–50 / Al 6–50 mm², 2P, blue, 160/145 A FT1050N2 (2P, for the N circuit) Cu 2.5–50 / Al 6–50 mm², 2P, green-yellow, 160/145 A FT1050G2 (2P, for the PE circuit) Cu 2.5–50 / Al 6–50 mm², 2P, grey, 160/145 A FT1050F2 (2P, for the L circuit) Cu 16–95 / Al 16–95 mm², 2P, blue, 245/220 A FT1095N2 (2P, for the N circuit) ← this model Cu 16–95 / Al 16–95 mm², 2P, green-yellow, 245/220 A FT1095G2 (2P, for the PE circuit) Cu 16–95 / Al 16–95 mm², 2P, grey, 245/220 A FT1095F2 (2P, for the L circuit) Cu 35–150 / Al 35–150 mm², 2P, blue FT1150N2 (2P, for the N circuit) Cu 35–150 / Al 35–150 mm², 2P, green-yellow FT1150G2 (2P, for the PE circuit) Cu 35–150 / Al 35–150 mm², 2P, grey FT1150F2 (2P, for the L circuit) Cu 35–240 / Al 35–240 mm², 2P, blue FT1240N2 (2P, for the N circuit) Cu 35–240 / Al 35–240 mm², 2P, green-yellow FT1240G2 (2P, for the PE circuit) Cu 35–240 / Al 35–240 mm², 2P, grey FT1240F2 (2P, for the L circuit) Cu 1.5–16 / Al 1.5–16 mm², 3P, blue, 85 A FT1016N3 (3P, for the N circuit) Cu 1.5–16 / Al 1.5–16 mm², 3P, green-yellow, 85 A FT1016G3 (3P, for the PE circuit) Cu 1.5–16 / Al 1.5–16 mm², 3P, grey, 85 A FT1016F3 (3P, for the L circuit) Cu 2.5–35 / Al 2.5–35 mm², 3P, blue, 135/120 A FT1035N3 (3P, for the N circuit) Cu 2.5–35 / Al 2.5–35 mm², 3P, green-yellow, 135/120 A FT1035G3 (3P, for the PE circuit) Cu 2.5–35 / Al 2.5–35 mm², 3P, grey, 135/120 A FT1035F3 (3P, for the L circuit) Cu 2.5–50 / Al 6–50 mm², 3P, blue, 160/145 A FT1050N3 (3P, for the N circuit) Cu 2.5–50 / Al 6–50 mm², 3P, green-yellow, 160/145 A FT1050G3 (3P, for the PE circuit) Cu 2.5–50 / Al 6–50 mm², 3P, grey, 160/145 A FT1050F3 (3P, for the L circuit) Cu 16–95 / Al 16–95 mm², 3P, blue, 245/220 A FT1095N3 (3P, for the N circuit) Cu 16–95 / Al 16–95 mm², 3P, green-yellow, 245/220 A FT1095G3 (3P, for the PE circuit) Cu 16–95 / Al 16–95 mm², 3P, grey, 245/220 A FT1095F3 (3P, for the L circuit) Cu 35–150 / Al 35–150 mm², 3P, blue FT1150N3 (3P, for the N circuit) Cu 35–150 / Al 35–150 mm², 3P, green-yellow FT1150G3 (3P, for the PE circuit) Cu 35–150 / Al 35–150 mm², 3P, grey FT1150F3 (3P, for the L circuit) Cu 35–240 / Al 35–240 mm², 3P, blue FT1240N3 (3P, for the N circuit) Cu 35–240 / Al 35–240 mm², 3P, green-yellow FT1240G3 (3P, for the PE circuit) Cu 35–240 / Al 35–240 mm², 3P, grey FT1240F3 (3P, for the L circuit) Cu/Al 2.5–35 mm², 3P+N+PE FT503500 (five-pole block for a three-phase line) Cu 2.5–50 / Al 6–50 mm², 3P+N+PE FT505000 (five-pole block for a three-phase line) Rule: choose the terminal according to the smallest and largest conductor to be connected (Cu and Al ranges differ in FT1050 models), the colour according to the circuit (N – blue, G – green-yellow PE, F – grey for phase L), and the number of poles according to how many separate lines need to be connected; for a three-phase line with N and PE in one block, FT503500 and FT505000 are available.When to choose another solution: other colours – FT1095G2, FT1095F2; other number of poles – FT1095N, FT1095N3; for thicker cables – FT1150 (35–150 mm²) or FT1240 (35–240 mm²); 3P+N+PE blocks – FT503500, FT505000; distribution terminals DTB080–DTB500; insulated terminals F807–F815; DIN rails FD010100–FD011000; end stop EW-35.Pros
- Rated current 245 A (Cu) / 220 A (Al), voltage 1000 V AC / 1500 V DC
- Copper 16–95 mm² and aluminium 16–95 mm² conductors
- Colour coding of the N circuit (blue)
- 2P, 4 contacts in one product – fewer parts
- Standards IEC/EN 60947-7-1, IEC/EN 61238-1
- Polyamide PA66 housing, operating temperature -25…+55 °C
- Mounting on a 35×7.5 mm DIN rail
Cons / limitations
- Degree of protection IP20 – install only in closed panels or cabinets
- The minimum wire is 16 mm², so for thinner conductors choose FT1050 or FT1035; for conductors thicker than 95 mm² – FT1150 or FT1240
- Fixed colour – for a different circuit you will need FT1095G2, FT1095F2
- Fixed number of poles – for a different number of lines choose FT1095N, FT1095N3
- Correct tightening torque and Al conductor preparation (oxide removal, contact paste) are essential
Safety and installation notes
- Installation and connection must be carried out only by a qualified electrician after disconnecting the supply and verifying that the circuit is de-energised.
- Do not exceed the rated current of 245 A (Cu) / 220 A (Al) and the rated voltage of 1000 V AC / 1500 V DC.
- Tighten the clamps to the specified torque – 20 Nm (16–95 mm²) – and check the connections after the first load and during periodic maintenance.
- The terminal is IP20 – install only in a closed panel or cabinet, operating temperature -25…+55 °C.
- Use the blue terminal only for the neutral (N) circuit; fit an EW-35 end stop at the ends of the row.
Quick selection guide
2P245/220 A1000 V AC / 1500 V DCCu 16–95 / Al 16–95 mm²blue (N)DIN 35IP20Suitable when you need:- connect or distribute neutral (N) conductors in the control panel;
- connect copper 16–95 mm² and aluminium 16–95 mm² conductors up to 245 A (Cu) / 220 A (Al);
- connect 2 separate lines in one product.
Check before use:- the smallest and largest conductor to be connected – whether it fits Cu 16–95 mm² / Al 16–95 mm²;
- load current – no more than 245 A (Cu) / 220 A (Al);
- circuit – the blue housing corresponds to N; other circuits will require FT1095G2, FT1095F2.
Important reminder: FT1095N2 – 2P blue terminal for the N circuit; versions in other colours and pole counts, as well as EW-35, are ordered separately.FAQ
What does the letter N mean in the code FT1095N2?
The letter N denotes a blue housing for the N circuit; in the FT series, N stands for the blue, G for the green-yellow and F for the grey version.What wire cross-sections can be connected?
Copper 16–95 mm² and aluminium 16–95 mm² conductors; Al conductors must be cleaned of oxide and coated with contact paste before connection.How many poles and contacts does FT1095N2 have?
FT1095N2 is a 2P terminal with 4 contacts (2 per pole); in the FT series, a code without a suffix means 1P, suffix 2 – 2P, suffix 3 – 3P.What are the rated current and voltage?
Rated current 245 A (Cu) / 220 A (Al), rated voltage 1000 V AC / 1500 V DC.What tightening torque should be used for the screws?
Depending on the conductor cross-section: 20 Nm (16–95 mm²).How is the terminal installed?
The terminal is clipped onto a 35×7.5 mm DIN rail, and an EW-35 end stop is fitted at the ends of the row.Power distribution terminal | 2P | 245/220 A (Cu/Al) | Cu 16–95 mm² / Al 16–95 mm² | 1000 V AC | DIN 35 | blue (N) | Promfactor Baltic | FT1095N2
Promfactor Baltic FT1095N2 – 2P power distribution terminal 245 A (Cu) / 220 A (Al), 1000 V AC / 1500 V DC, for copper 16–95 mm² and aluminium 16–95 mm² wires, blue housing for the N circuit, IP20, DIN rail mounting, IEC/EN 60947-7-1, IEC/EN 61238-1.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Aluminium power cable | 4x50mm² | AXMK | Class 2 | 1500m | BlackCode: SKU#165996533759726861Aluminium power cable AXMK 4×50 mm², designed for fixed 0.6/1 kV power transmission and distribution installations. The cable features Class 2 aluminium conductors, XLPE insulation and a black UV-resistant PVC sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits and concrete. Maximum operating temperature – 90 °C.
Sold by the drum, i.e. the minimum order quantity is 1500 metres.
Delivery time: up to 6 weeks.
Price 6.32 € VAT incl.( 5.22 € VAT excl. )Terminal | connector paste for contacts | reduces oxidation | 35.3g | WAGO | ALU PLUS | 249-130 | for connecting aluminium and copper wiresCode: 4017332133890Contact paste designed to protect aluminum conductors from oxidation and ensure a reliable electrical connection. This special paste allows aluminum and copper conductors to be safely and efficiently connected within the same connector, making it particularly useful when renovating older electrical installations where aluminum wiring is commonly found.
Aluminum naturally oxidizes, and the resulting oxide layer increases contact resistance, causes connection heating, and may become a source of electrical faults. By using WAGO ALU-PLUS, the oxidation layer is reduced, electrical conductivity is improved, and the service life of the connection is significantly extended.
Price 2.83 € VAT incl.( 2.34 € VAT excl. )