    Barcode: 5907760638762

    Digital weekly time relay for DIN rail: 16 A / 3600 W, 8 programs, LCD, memory backup up to 100 h.

  • Programmable time relay (weekly timer) | 16 A | 3600 W | 230 V | LCD | DIN 2 mod. | Lexton LX-U05 TS-GE2 | 5907760638762

    Lexton LX-U05 is a digital weekly time relay for DIN rail mounting in an electrical distribution board. It switches loads up to 16 A / 3600 W on and off according to a set schedule – lighting, a water heater, ventilation, a pump or any other 230 V consumer. Programs are set with buttons and the status is shown on the LCD display.

    Key point:
    When equipment should only run at certain hours or on certain days, a time relay removes the human factor – nobody forgets to switch it on or off. It is installed in the board, so control is permanent and protected from accidental disconnection. A simple way to save energy and make use of cheaper tariff hours.
    Load
    16 A / 3600 W
    Programs
    8 ON/OFF, 16 day combinations
    Mounting
    DIN TH35, 2 modules
    Memory backup
    up to 100 h

    How it works

    The relay snaps onto a TH35 DIN rail and occupies 2 modules (35 mm). The supply and the controlled circuit are connected according to the manufacturer’s diagram on the housing.

    The internal clock runs on a 24 h / 7-day cycle. Each of the 8 programs is given an on and off time and one of 16 day combinations – for example every day, weekdays only or weekends only. At the set time the relay contact connects or disconnects the load.

    If mains voltage is lost, the built-in rechargeable battery keeps the clock and programs for up to 100 hours – when power returns, the schedule continues without reprogramming.

    Why choose the Lexton LX-U05?
    It lets you automate a single 230 V circuit at board level on a weekly schedule, without an interposing relay for most household and small commercial loads up to 16 A.

    Technical specifications

    Product type Digital weekly time relay (programmable timer) for DIN rail
    Manufacturer Lexton
    Model LX-U05 (TS-GE2)
    EAN 5907760638762
    Supply voltage 220–240 V AC
    Rated current 16 A
    Maximum load 3600 W
    Display LCD
    Programming cycle 24 h / 7 days
    Number of programs 8 ON/OFF programs
    Day combinations 16
    Time format 12 / 24 h
    Controls 7 buttons
    Memory backup Built-in rechargeable battery, up to 100 h
    Mounting DIN rail TH35
    Width 2 modules (35 mm)

    Key functions

    • Weekly programming – different schedules for weekdays and weekends.
    • 8 programs and 16 day combinations – the load can be switched on and off several times a day.
    • 16 A / 3600 W contact – directly controls most household loads without an extra contactor.
    • Memory backup up to 100 h – the schedule is not lost during short or longer power outages.
    • 2-module DIN housing – fits a standard board next to circuit breakers.
    • LCD display and 12/24 h format – time and programs are clearly visible while programming.

    Where is it used?

    • Water heater (boiler) control during cheaper tariff hours
    • Yard, façade and site lighting
    • Shop windows, signs, advertising lighting
    • Stairwell and common area lighting by working hours
    • Ventilation and extract fan schedules
    • Hot water circulation pump control
    • Greenhouse, grow and aquarium lighting
    • Farm building lighting and auxiliary equipment

    Use by need

    For electricians and panel builders.
    A compact 2-module solution mounted alongside protective devices without extra enclosures.
    For home and country house owners.
    The boiler, yard light or pump runs on schedule – lower costs without daily attention.
    For small commercial premises managers.
    Shop windows, signs and ventilation switch on and off by working hours, even if staff forget.

    Practical application

    If a house has a two-zone tariff meter and a 2 kW water heater, the LX-U05 is installed in the board in the heater circuit. Heating is programmed only for cheaper tariff hours, with a separate schedule for weekends. Result: the heater does not run at the expensive rate, and there is enough hot water for morning and evening.

    Pros

    • 16 A / 3600 W load directly through the relay
    • Weekly schedule with 16 day combinations
    • Memory backup up to 100 h
    • Occupies only 2 modules on the DIN rail
    • Clear LCD display, simple button programming
    • Permanent installation – cannot be unplugged by accident

    Cons / limitations

    • Works by the clock – no astronomical (sunset) function is listed in the specification; outdoor lighting needs seasonal adjustment or a twilight switch
    • No remote (Wi-Fi / app) control
    • 8 programs may not be enough for very complex schedules
    • Motors, compressors and loads with high inrush current – via a contactor
    • For board installation only, not for a plug-in socket

    Safety and installation notes

    • Installation and wiring must be done by a qualified electrician with the power disconnected.
    • Protect the controlled circuit with a circuit breaker rated no higher than 16 A.
    • Select the cable cross-section according to the actual load current.
    • Do not exceed 16 A / 3600 W; for loads near the limit or with high inrush current use a contactor with a 230 V coil.
    • Do not connect three-phase consumers directly through the relay – only via a contactor.
    • Follow the manufacturer’s wiring diagram on the housing.

    Quick selection guide

    16 A
    3600 W
    220–240 V AC
    DIN 2 mod.
    8 programs
    LCD
    Suitable when you need:
    • to control one 230 V circuit on a weekly schedule
    • a permanent board-mounted solution instead of a plug-in timer
    • to make use of cheaper tariff hours
    Check before use:
    • that 2 free modules are available in the board
    • the load current and type (resistive, inductive, LED with inrush current)
    • that the circuit is protected by a breaker no higher than 16 A
    • whether 8 programs are enough for your schedule
    Important reminder: a time relay is a control device, not a protective device – it does not replace a circuit breaker, RCD or a contactor for high-power loads.

    FAQ

    Can it directly control a water heater?
    Yes, if its power does not exceed 3600 W and the circuit is protected by a breaker no higher than 16 A.
    What happens during a power cut?
    The built-in rechargeable battery keeps the clock and all programs for up to 100 hours.
    How much board space does it take?
    2 modules (35 mm) on a standard TH35 DIN rail.
    Can I set a different schedule for weekends?
    Yes – each program is assigned one of 16 day combinations.
    Is it suitable for outdoor lighting?
    Yes, but the relay works by the clock, so switching times must be adjusted seasonally or combined with a twilight switch.
    Can it control a three-phase motor?
    Not directly; yes via a contactor whose coil is controlled by the time relay.

    Programmable time relay Lexton LX-U05 | 16 A | DIN

    Digital weekly time relay for DIN rail: 16 A / 3600 W, 8 programs, 16 day combinations, LCD display and memory backup up to 100 h. A reliable way to automate lighting, a water heater, ventilation or pumps in the distribution board on a weekly schedule.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Modular photo relay | twilight switch with external sensor | 16 A | 12–240 V AC/DC | 1–50,000 lx | 1CO | DIN | GanzKK | SOU-1/UNI
    Code: SOU-1/UNI

    DIN rail twilight switch with universal 12–240 V AC/DC supply and external sensor: 1–50,000 lx, 1CO 16 A AC1, 0–2 min delay, 1 module.

    Price 42.47 € VAT incl.
    ( 35.10 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information