  • Three-phase voltage relay | 3F+N | 40 A (max. 50 A) | U> 210–270 V | U< 120–200 V | asymmetry | phase sequence | DIN | DigiTOP | VP-3F40A

    Code: VP-3F40A

    The DigiTOP VP-3F40A is a three-phase digital voltage relay with neutral connection (3F+N) that monitors the voltage of each phase separately, phase asymmetry and phase sequence.

  • Three-phase voltage relay | 3F+N | 40 A (max. 50 A) | U> 210–270 V | U< 120–200 V | asymmetry | phase sequence | DIN | DigiTOP | VP-3F40A

    The DigiTOP VP-3F40A is a three-phase digital voltage relay with neutral connection (3F+N) that monitors the voltage of each phase separately, phase asymmetry and phase sequence. The load current passes through the relay contacts – 40 A (briefly up to 50 A) in each phase.

    Key point:
    One relay protects the whole three-phase supply. In asynchronous mode it works like three separate single-phase relays and disconnects only the faulty phase. In synchronous mode it disconnects all phases together and checks phase sequence and asymmetry – protecting three-phase motors and pumps.
    Load current
    40 A (max. 50 A)
    Network
    3F+N, 3×230/400 V
    Asymmetry
    adjustable, trips after 20 s
    Modes
    synchronous / asynchronous

    How it works

    The relay is connected to a three-phase supply with neutral (L1, L2, L3, N). The voltage of each phase is measured separately and shown on the display.

    In asynchronous mode each phase is controlled separately – suitable when single-phase equipment is supplied from a three-phase connection. In synchronous mode a fault in any phase disconnects all phases; phase sequence and asymmetry are also checked (trips after 20 s).

    When the voltage returns to normal, the load is reconnected after the set delay of 5–600 s. Settings are stored in non-volatile memory.

    Why choose the VP-3F40A?
    One device instead of three single-phase relays and a phase monitoring relay: it protects both single-phase equipment and three-phase motors, and the display shows the voltage of each phase.

    Technical specifications

    Product type Three-phase digital voltage relay
    Manufacturer / model DigiTOP / VP-3F40A
    Network 3F+N, 3×230/400 V AC
    Rated load current 40 A
    Maximum load current 50 A
    Measured voltage 50–400 V
    Upper limit U> 210–270 V (factory 250 V)
    Lower limit U< 120–200 V (factory 170 V)
    Trip time below the limit up to 1 s (120–170 V), instantly below 120 V
    Switch-on delay 5–600 s, 5 s step (factory 15 s)
    Phase asymmetry adjustable, trips after 20 s
    Phase sequence monitoring can be switched on / off
    Operating modes synchronous (3F load) / asynchronous (1F loads)
    Voltage measurement error up to 1 %
    Display LED, red
    Dimensions 105 × 90 × 67 mm
    Mounting 35 mm DIN rail
    Operating temperature −25…+50 °C
    Degree of protection IP20 (in damp locations only in a sealed enclosure)

    Main functions

    • Overvoltage protection – with a broken neutral or a network fault, appliances are disconnected before their power supplies burn out.
    • Undervoltage protection – compressors and pumps do not run at a voltage at which motors overheat.
    • Adjustable switch-on delay 5–600 s – the compressor starts only after pressure has equalised, equipment does not cycle during an unstable supply.
    • Digital voltage display – you see immediately whether the problem is in the grid or in the house.
    • Asymmetry and phase sequence monitoring – three-phase motors are protected from overheating and reverse rotation.
    • Two modes – synchronous for three-phase equipment, asynchronous for single-phase loads in a three-phase house.

    Where is it used?

    • Three-phase supplies of houses and country homes
    • Workshops, garages, farm buildings
    • Three-phase pumps, compressors, machine tools
    • Heat pumps with three-phase supply
    • Small production and storage premises
    • Sites with an overhead line connection

    Use by need

    For the owner of a three-phase house.
    One relay protects all three phases and shows the voltage of each.
    For a workshop or farm owner.
    Synchronous mode protects three-phase motors against a lost phase and asymmetry.
    For the electrician.
    One device instead of several – fewer connections and less space in the board.

    Practical use

    A country house has a three-phase supply: the pump and workshop machines are three-phase, the house has single-phase equipment. In asynchronous mode the relay disconnects only the faulty phase, while in the circuit for three-phase motors synchronous mode disconnects all phases together in case of a fault.

    Pros

    • Monitors each phase separately
    • Synchronous and asynchronous modes
    • Asymmetry and phase sequence monitoring
    • Full load through the relay
    • Settings in non-volatile memory

    Cons / limitations

    • Does not protect against lightning and short surges – an SPD is needed
    • Does not replace circuit breakers and RCDs
    • Takes a lot of space in the board
    • Neutral conductor required (3F+N)

    Safety and installation notes

    • Install only after disconnecting the supply and checking that no voltage is present; work must be done by a qualified electrician.
    • A circuit breaker with a rated current not higher than the relay's rated current must be installed upstream.
    • Use ferrules for stranded wires and tighten terminals to the torque specified by the manufacturer.
    • Do not swap phase and neutral – otherwise the phase remains connected to the equipment when the relay trips.
    • Install the surge protective device (SPD) before the relay, closer to the supply point.
    • Do not install in damp, vibrating or explosive environments.

    Quick selection guide

    3F+N | 400 V
    40 A | max. 50 A
    asymmetry
    phase sequence
    sync / async
    Suitable when you need:
    • to protect a three-phase supply with one relay
    • to protect three-phase motors
    • to see the voltage of all phases
    Check before use:
    • main circuit breaker current ≤ 40 A
    • whether the supply has an N conductor
    • choose the right operating mode
    Important reminder: the relay does not protect against lightning surges and short circuits – SPDs and circuit breakers are needed for that.

    FAQ

    What is the difference between synchronous and asynchronous mode?
    Synchronous disconnects all phases together (for three-phase motors), asynchronous only the faulty phase (for single-phase loads).
    Is a neutral conductor required?
    Yes – the relay measures phase voltages relative to neutral, so it is connected as 3F+N.
    Does it protect against lightning?
    No – a surge protective device (SPD) is intended for that.
    What current should I choose?
    Not lower than the main circuit breaker current – the VP-3F40A suits a breaker up to 40 A.
    Can phase sequence monitoring be switched off?
    Yes – it is switched on or off in the settings.
    Are settings kept during a power cut?
    Yes – settings are stored in non-volatile memory.

    Three-phase voltage relay | 3F+N | 40 A (max. 50 A) | U> 210–270 V | U< 120–200 V | asymmetry | phase sequence | DIN | DigiTOP | VP-3F40A

    Three-phase voltage relay DigiTOP VP-3F40A – voltage, asymmetry and phase sequence monitoring of all three phases for a three-phase supply.

    Published: 2026-11-13 · Data verified against the manufacturer's manual: 2026-11-13

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • privacy policy

    Information