Products catalog

Switches | Keys for automation devices control | control systems

  • Knob and key selector switches 22 mm for control panels and automation

    Selector switches are used to select the operating mode and switch equipment on: 2 and 3 positions, maintained and spring return, with LED illumination and with key. All of them are intended for control circuits – contactor coils, relays and controller inputs.

    Subgroups:KnobIlluminatedKey

    Push buttonsAccessoriesEnclosures and indicator lampsBuzzers

    Kibirkštis
    KibirkštisWhat selector switch should I use for a pump with MANUAL and AUTO modes?
    Fazė
    FazėA 3-position 1-0-2 maintained switch with 2NO contacts. The thermal relay must protect in both modes. You will find the full selection and diagram in the guide below.

    ⚡ Selection guide – ELSprendimai recommends

  • Selector switch guide: knob or key, 2 or 3 positions, maintained or spring return

    Here you will find quick selection by situation, 5 solution levels from a plastic selector switch to a key switch, position and contact logic, a MANUAL–0–AUTO mode diagram and the most common mistakes. Exact parameters are given in each product description.

    Colour meanings: ■ information · ■ benefit, solution · ■ ⚠ check · ■ ⚡ safety, mistakes

    ⚡ Selection in 30 s
    ELSprendimai recommends

    What do you need? Quick selection

    Situation Solution Where to look
    Simple ON–OFF on a panel door in a dry room Knob selector switch, 2 positions 0-1, maintained plastic 0-1, metal 0-1
    MANUAL–0–AUTO modes for a pump, fan or compressor 3-position 1-0-2 selector switch, maintained, with 2NO contacts plastic 1-0-2, metal 1-0-2
    You need to see that the selected mode is active Illuminated 3-position selector switch. The LED voltage must match the control voltage green LED 230 V, green LED 24 V, red LED 230 V
    Short command only while held: JOG, OPEN–CLOSE, LEFT–RIGHT Spring-return selector switch, returns to 0 when released plastic 3-pos. spring return, metal 3-pos. spring return, metal 2-pos. spring return
    Only an authorised person may switch on: service, public area, lockout Key selector switch, 2 positions 0-1 key, plastic, key, metal
    Anyone can stop, but only a key holder can restart Mushroom STOP button released with a key mushroom with key
    You need to start and stop a motor This is a job for push buttons, not a selector: START–STOP with contactor self-holding Push button guide
    The switch is mounted at the machine, not in a panel Selector switch plus push button enclosure (1–3 positions) push button enclosures
    The right selector switch means four decisions: operation (knob or key), number of positions (2 or 3), action (maintained or spring return) and indication (with or without LED). The number of contacts follows from the positions: 1NO is enough for 2 positions, 3 positions need 2NO.

    From basic to secure: 5 solution levels

    Start at level 1 and move up only when the environment or function requires it. A key or LED is not “better” everywhere. They are needed only where they prevent a mistake or show the status.

    LEVEL 1

    Plastic knob

    For: panel doors in dry rooms, building automation, repairs

    What you get: 2 or 3 positions, maintained or spring return, IP40

    Price from 2.11 € incl. VAT

    0-1 maintained · 1-0-2 maintained · 3-pos. spring return

    LEVEL 2

    Metal knob

    For: production lines, workshops, machine tools, frequent switching

    What you get: sturdy metal front ring, the same position versions

    Price from 3.21 € incl. VAT

    0-1 maintained · 1-0-2 maintained · 0-1 spring return · 1-0-2 spring return

    LEVEL 3

    With LED illumination

    For: when the operator must see the selected mode or operation

    What you get: switch and indicator in one, 24 V or 230 V, 3 positions

    Price from 5.03 € incl. VAT

    230 V: green · red · green, plastic
    24 V: green · red

    LEVEL 4

    With key

    For: service, public sites, equipment that outsiders must not switch on

    What you get: position changed only with the key, 2 positions 0-1

    Price from 4.17 € incl. VAT

    plastic · metal

    LEVEL 5

    Mushroom STOP with key

    For: anyone can stop, but only an authorised person can restart

    What you get: latching NC mushroom released with a key

    Price from 4.38 € incl. VAT

    mushroom STOP with key

    Positions and action: how they work

    Type How it works Where to use
    2 positions 0-1, maintained The knob stays where you turned it: 0 – off, 1 – on ON–OFF, lighting group, heating, ventilation without contactor self-holding
    2 positions 0-1, spring return Position 1 works only while held, the released knob returns to 0 Pulse: e.g. ACKNOWLEDGE, JOG, short start
    3 positions 1-0-2, maintained Left (1), centre (0), right (2), each position stays MANUAL–0–AUTO, SUMMER–0–WINTER, pump 1 or 2
    3 positions 1-0-2, spring return 1 and 2 work only while held, return to 0 when released OPEN–CLOSE, UP–DOWN, LEFT–RIGHT
    With key The position can be changed only by inserting and turning the key Service, enable permission, public sites
    Kibirkštis
    KibirkštisWhy can’t I just take a maintained 3-position switch and use it for OPEN–CLOSE?
    Fazė
    FazėYou can, but then the gate or damper will keep moving until someone returns the knob to 0. Without limit switches the drive will reach the end and overheat. A spring-return switch stops the movement as soon as you let go.

    Contacts: what closes in each position

    Our selector switches have NO contacts. A 3-position switch has two NO contacts (2NO): one closes in position 1, the other in position 2. In the centre (0) both are open, so both modes can never be on at the same time.

    Position Contact A Contact B
    1 closed open
    0 open open
    2 open closed

    A 2-position switch (0-1) has one NO contact: open in position 0, closed in position 1.

    ⚠ Check the terminal marking (e.g. 13–14, 23–24) and which side is “1” on the specific product before wiring.

    LED illumination: what voltage do you need?

    The LED of an illuminated selector switch is powered from the control circuit, so its voltage must match the control voltage: for 24 V control choose LED 24 V, for 230 V control – LED 230 V. A 24 V LED on 230 V burns out instantly, and a 230 V LED on 24 V will not light.

    Selection matrix: all selector switches in the group

    All selector switches mount in a Ø 22 mm hole, front protection degree IP40, standard IEC/EN 60947-5.

    Product Operation Positions Action Contacts LED Ring Price
    View knob 0-1 maintained 1NO — plastic 2.11 €
    View knob 1-0-2 maintained 2NO — plastic 3.17 €
    View knob 1-0-2 spring return 2NO — plastic 3.17 €
    View knob 0-1 maintained 1NO — metal 3.21 €
    View knob 0-1 spring return 1NO — metal 3.21 €
    View knob 1-0-2 maintained 2NO — metal 3.82 €
    View knob 1-0-2 spring return 2NO — metal 3.82 €
    View knob, green 1-0-2 maintained 2NO LED 230 V plastic 5.03 €
    View knob, green 1-0-2 maintained 2NO LED 230 V metal 6.55 €
    View knob, red 1-0-2 maintained 2NO LED 230 V metal 6.55 €
    View knob, green 1-0-2 maintained 2NO LED 24 V metal 6.55 €
    View knob, red 1-0-2 maintained 2NO LED 24 V metal 6.55 €
    View key 0-1 maintained 1NO — plastic 4.17 €
    View key 0-1 maintained 1NO — metal 4.66 €

    ⚠ What to check before buying

    Kibirkštis
    KibirkštisBefore ordering a selector switch I always check these things, otherwise I have to make a second trip.
    What to check Why it matters
    Number of positions: 0-1 or 1-0-2 Two modes plus OFF need 3 positions
    Maintained or spring return Modes – maintained, movement commands – spring return
    Number of contacts 3 positions need 2NO. If you need a signal to a controller, plan an additional contact block
    Knob or key A key is needed when only an authorised person may switch on or change the mode
    LED voltage Must match the control circuit: 24 V or 230 V
    Hole diameter Standard Ø 22 mm. Older 30 mm panels need another solution
    Environment IP40 is suitable for dry rooms. Outdoors and in washdown areas a sealed enclosure is needed

    ✗ Most common mistakes

    Mistake Consequence
    Maintained ON switch instead of START–STOP buttons for a motor When voltage drops and returns, the motor starts by itself. If this endangers people, use push buttons with contactor self-holding
    Two separate MANUAL and AUTO switches Both modes can be switched on at the same time. A 3-position 1-0-2 switch prevents this
    MANUAL mode bypasses the thermal relay or dry-run protection In manual mode the pump can burn out or run dry
    Maintained switch for movement commands The gate or damper keeps moving until someone returns the knob. A spring-return switch is needed
    The switch switches motor current directly Contacts burn. The switch controls the contactor coil, not the motor
    LED voltage does not match the control voltage The LED burns out or does not light
    Fazė

    ⚡ Safe installation – Fazė’s advice

    • Before installation, disconnect the panel and verify that there is no voltage.
    • Protect the control circuit with a separate circuit breaker or fuse according to the wire cross-section.
    • Wire the thermal relay contact and dry-run protection so that they work in both modes: MANUAL and AUTO.
    • Stick a position label on the switch (e.g. MAN – 0 – AUTO) so that the operator does not make a mistake.
    • Metal doors must be connected to PE.
    ☝ Elsprendimai.eu recommends: complete selector switches with START–STOP push buttons, indicator lamps for mode indication, additional contacts and accessories, enclosures, contactors and thermal relays.

    Diagram: pump MANUAL–0–AUTO modes – wrong and right

    The pump is controlled by contactor KM. In AUTO mode it is switched on by an automation contact (float switch, pressure switch or controller). The numbers match the explanations below the diagram.

    Elektrotechnikos sprendimai
    ✗ Wrong
    L
    no protection 3
    →
    MAN switch
    separate 0-1 1
    AUTO switch
    separate 0-1 1
    →
    KM coil
    no thermal relay 2

    1 Both modes can be switched on at the same time 2 Manual mode bypasses overload protection 3 Control circuit without its own protection

    ✓ Right
    L
    breaker / fuse 3
    →
    Thermal relay
    95–96 NC 2
    →
    Selector 1-0-2
    1 = MAN · 0 · 2 = AUTO 1
    →
    2 = AUTO
    via automation contact
    →
    KM coil
    A1–A2 → N

    1 One 3-position switch: both modes at once are impossible 2 The thermal relay protects in both modes 3 Separate protection for the control circuit

    The diagram is a simplified schematic and may contain inaccuracies. Before wiring, check against the manufacturer’s instructions and the markings on the devices. The qualified electrician performing the installation is responsible for it. UAB „Elektrotechnikos sprendimai“ is not liable for the wiring or possible errors.

    Why – explanation by diagram numbers

    1 ✗ Two separate switches → ✓ One 1-0-2 selector switch
    Why: a 3-position switch physically prevents both modes from being on, and position 0 clearly means “off”.

    2 ✗ Manual bypasses protection → ✓ Thermal relay contact before the selector
    Why: overload and dry running are dangerous in both modes, so protection must be in the common part of the circuit.

    3 ✗ Control without its own protection → ✓ Separate breaker or fuse
    Why: thin control wires must be protected according to their own cross-section.

    Frequently asked questions

    Questions from Kibirkštis – a young, curious electrician. Answers from Fazė – an experienced master.

    Kibirkštis
    KibirkštisWhat is the difference between a knob and a key selector switch?
    Fazė
    FazėAnyone can turn a knob, but only the key holder can turn a key switch. A key is suitable where switching on or changing the mode must be controlled, e.g. a metal key selector switch.
    Kibirkštis
    KibirkštisCan I switch a pump directly with a selector switch?
    Fazė
    FazėNo. A selector switch is intended for the control circuit. Connect the pump via a contactor with a thermal relay and let the switch control only the coil.
    Kibirkštis
    KibirkštisWhen should I choose a selector switch and when START–STOP buttons?
    Fazė
    FazėA selector switch is suitable for modes and equipment that can safely restart by themselves after a power loss (ventilation, lighting, heating). For motors that must not restart by themselves, use push buttons with contactor self-holding.
    Kibirkštis
    KibirkštisWhy does a 3-position switch have 2NO contacts?
    Fazė
    FazėEach position (1 and 2) needs its own contact. In the centre (0) both are open, so both modes cannot be on together.
    Kibirkštis
    KibirkštisIs an illuminated selector switch always lit?
    Fazė
    FazėThe LED lights when control voltage is applied to it. How you connect the LED (e.g. in parallel with the contactor coil) determines what status it shows. The LED voltage must match the control voltage.
    Kibirkštis
    KibirkštisDo you help select control devices for a whole panel?
    Fazė
    FazėYes. Send the diagram or list of functions, the control voltage and ambient conditions. We will select selector switches, buttons, lamps, contactors and protection and send a quote. Contact us.

    Other related guides: Push button guide · Exit door button guide · All product selection guides

    Sources

    • EN 60204-1 – Electrical equipment of machines (control devices, protection against unexpected start-up)
    • IEC/EN 60947-5-1 – Control circuit devices and switching elements
    • Promfactor Baltic FP series manufacturer data and product marking

    This guide is for information purposes and does not replace a design, a risk assessment or the manufacturer’s instructions. UAB „Elektrotechnikos sprendimai“ accepts no liability for product selection based on this guide. The final decision is made by the designer or a qualified electrician. Published: 2026-11-06.

    Selector switches, buttons, lamps and contactors – in one order

    Send a diagram or a list and we will prepare a quote. Model not in the catalogue? Some products are supplied to order.

    Get a quote +370 658 01033
    Read more
    Key selector switch | 22 mm | 1NO | 2 positions 0-1 | latching | metal | IP40 | Promfactor Baltic | FP CKL bl
    Code: FP CKL bl

    FP CKL bl – metal key selector switch (2 positions 0-1, latching) with 1NO, Ø 22 mm, IP40, for modes and control in panels and control desks.

    Price 4.66 € VAT incl.
    ( 3.85 € VAT excl. )
    Illuminated selector switch | 22 mm | 2NO | 3 positions 1-0-2 | latching | green | LED 230 V | plastic | IP40 | Promfactor Baltic | FP5-AK3365230
    Code: FP5-AK3365230

    FP5-AK3365230 – plastic illuminated three-position selector switch (3 positions 1-0-2, latching) with 2NO and a 230 V LED, Ø 22 mm, IP40, for modes in panels.

    Price 5.03 € VAT incl.
    ( 4.16 € VAT excl. )
    Selector switch | 22 mm | 2NO | 3 positions | non-latching (returns to 0) | black | plastic | IP40 | Promfactor Baltic | FP5-AD53
    Code: FP5-AD53

    FP5-AD53 – plastic three-position spring-return selector switch (3 positions, non-latching, knob returns to 0) with 2NO, Ø 22 mm, IP40, for modes in panels.

    Price 3.17 € VAT incl.
    ( 2.62 € VAT excl. )
    Selector switch | 22 mm | 2NO | 3 positions 1-0-2 | latching | black | plastic | IP40 | Promfactor Baltic | FP Rec3 bl Pl
    Code: FP Rec3 bl Pl

    FP Rec3 bl Pl – plastic three-position selector switch (3 positions 1-0-2, latching) with 2NO, Ø 22 mm, IP40, for modes and control in panels and control desks.

    Price 3.17 € VAT incl.
    ( 2.62 € VAT excl. )
    Selector switch | 22 mm | 1NO | 2 positions 0-1 | latching | black | plastic | IP40 | Promfactor Baltic | FP Rec2 bl Pl
    Code: FP Rec2 bl Pl

    FP Rec2 bl Pl – plastic knob selector switch (2 positions 0-1, latching) with 1NO, Ø 22 mm, IP40, for modes and control in panels and control desks.

    Price 2.11 € VAT incl.
    ( 1.74 € VAT excl. )
    Key selector switch | 22 mm | 1NO | 2 positions 0-1 | maintained | black | plastic | IP40 | Promfactor Baltic | FP CKL bl Pl
    Code: FP CKL bl Pl

    A key selector switch: the position can be changed only with the key, protecting against unauthorised switching on or mode changes.

    Price 4.17 € VAT incl.
    ( 3.44 € VAT excl. )
    Selector switch | 22 mm | 1NO | 2 positions 0-1 | maintained | black | metal | IP40 | Promfactor Baltic | FP Rec2 bl
    Code: FP Rec2 bl

    A knob selector switch for choosing the operating mode, e.g. MANUAL–0–AUTO or ON–OFF.

    Price 3.21 € VAT incl.
    ( 2.65 € VAT excl. )
    Selector switch | 22 mm | 1NO | 2 positions 0-1 | spring return to 0 | black | metal | IP40 | Promfactor Baltic | FP Rec20 bl
    Code: FP Rec20 bl

    A knob selector switch for choosing the operating mode, e.g. MANUAL–0–AUTO or ON–OFF.

    Price 3.21 € VAT incl.
    ( 2.65 € VAT excl. )
    Selector switch | 22 mm | 2NO | 3 positions 1-0-2 | spring return to 0 | black | metal | IP40 | Promfactor Baltic | FP Rec30 bl
    Code: FP Rec30 bl

    A knob selector switch for choosing the operating mode, e.g. MANUAL–0–AUTO or ON–OFF.

    Price 3.82 € VAT incl.
    ( 3.16 € VAT excl. )
    Selector switch | 22 mm | 2NO | 3 positions 1-0-2 | maintained | black | metal | IP40 | Promfactor Baltic | FP Rec3 bl
    Code: FP Rec3 bl

    A knob selector switch for choosing the operating mode, e.g. MANUAL–0–AUTO or ON–OFF.

    Price 3.82 € VAT incl.
    ( 3.16 € VAT excl. )
    Illuminated selector switch | 22 mm | 2NO | 3 positions 1-0-2 | maintained | green | LED 230 V | metal | IP40 | Promfactor Baltic | FP RecI3 gr
    Code: FP RecI3 gr

    A knob selector switch with 230 V LED illumination: one 22 mm hole provides both mode selection and status indication.

    Price 6.55 € VAT incl.
    ( 5.41 € VAT excl. )
    Illuminated selector switch | 22 mm | 2NO | 3 positions 1-0-2 | maintained | green | LED 24 V | metal | IP40 | Promfactor Baltic | FP RecI3 gr24
    Code: FP RecI3 gr24

    A knob selector switch with 24 V LED illumination: one 22 mm hole provides both mode selection and status indication.

    Price 6.55 € VAT incl.
    ( 5.41 € VAT excl. )
    Illuminated selector switch | 22 mm | 2NO | 3 positions 1-0-2 | maintained | red | LED 230 V | metal | IP40 | Promfactor Baltic | FP RecI3 r
    Code: FP RecI3 r

    A knob selector switch with 230 V LED illumination: one 22 mm hole provides both mode selection and status indication.

    Price 6.55 € VAT incl.
    ( 5.41 € VAT excl. )
    Illuminated selector switch | 22 mm | 2NO | 3 positions 1-0-2 | maintained | red | LED 24 V | metal | IP40 | Promfactor Baltic | FP RecI3 r24
    Code: FP RecI3 r24

    A knob selector switch with 24 V LED illumination: one 22 mm hole provides both mode selection and status indication.

    Price 6.55 € VAT incl.
    ( 5.41 € VAT excl. )