Selection guide: how to choose switches, sockets and boxes
A switch or a socket looks like a simple item, yet this is exactly where people touch the electrical installation every day. The wrong IP rating in a bathroom, an overloaded multiple socket or a wire joint plastered into the wall are the most common reasons why an installation has to be repaired after a few years. This guide helps you choose components by three questions: where it is installed (dry or damp location, wall, furniture, floor), how it is installed (flush or surface mounting) and what load will be connected.
Blue – information Green – your benefit Orange – ⚠ check Red – ⚡ safety and mistakes
What do you need? Quick selection
|
Situation |
Solution |
Where to look |
|
New flat or house, dry rooms |
Flush-mounted installation of one series: 10 A switches, 16 A earthed sockets with child protection shutters, frames by number of gangs |
Sedna Design · ABB Basic55 and others |
|
Bathroom, shower room, laundry – areas outside the bathroom zones |
Sockets with a cover, IP44 or higher, are recommended; the circuit must have residual current protection IΔn ≤ 30 mA (mandatory). No sockets are installed in the hot room of a sauna |
Flush IP55 · Sedna socket with cover |
|
Garage, basement, workshop, outbuilding |
Surface weatherproof installation IP54–IP55: fixed on the wall, cable entered through a gland; socket circuit with residual current protection IΔn ≤ 30 mA |
Weatherproof surface · Legrand Plexo switch IP55 |
|
Outdoors: terrace, facade, yard |
Socket with self-closing cover IP44–IP66 and residual current protection IΔn ≤ 30 mA. The stated IP applies with the cover closed; with a plug inserted, protection is lower – install where water does not stand and no direct jet reaches |
Socket IP66 · all weatherproof |
|
Office desk, conference room, reception |
Socket block in the desktop (closing or pop-up) or on the desk edge: Schuko + USB-A/C, HDMI and RJ45 if needed |
For furniture · On the desk · Pop-up |
|
Kitchen island, workbench in a workshop |
Pop-up socket block – flush with the worktop when not in use; do not place it next to the sink or hob |
Pop-up blocks |
|
Open floor area: office, hall, exhibition |
Floor box with sockets and a cover; cables in floor ducts or raised floors. For wet-cleaned floors – floor boxes IP44 or higher |
Floor sockets |
|
Loft, country house, log house, restoration |
Retro switches and sockets (ceramic or plastic), twisted wires on insulators, frames made of ceramics, plastic or wood |
Retro installation · insulators |
|
Wall mounting: masonry, concrete, drywall |
Installation boxes Ø60 mm by wall type; for electronics (dimmers, USB sockets, smart modules) – deep boxes |
Installation boxes · deep 63 mm |
|
Wire connections, multimedia and network equipment in the wall |
Junction box by the number of wires; for a router and low-voltage equipment – an IT enclosure with a door |
Junction boxes and IT enclosures |
What you gain by choosing correctly
-
Switches, sockets and frames of one series give a uniform look and fit flush, with no gaps between frame and rocker.
-
In damp and outdoor locations, weatherproof components keep water and dust away from the contacts – fewer nuisance residual current device trips and oxidised terminals.
-
A socket block in the desk or floor lets you do without extension leads and cables underfoot.
-
A box of the right depth holds the wires neatly and later lets you replace the device with a smart one without breaking the wall.
Flush or surface installation?
Flush-mounted
The device is fitted into an installation box in the wall; only the frame and rocker are visible. Cables are hidden in plaster, drywall or chases. Standard for homes and offices.
Surface-mounted
The component is fixed on the wall surface; the cable arrives in a trunking or conduit. Quick installation without chasing walls: garages, basements, technical rooms, renovation.
Weatherproof
Flush or surface, but with seals and covers (IP44 and higher). For damp, dusty and outdoor locations.
Open retro
Surface ceramic or plastic components and twisted wires on insulators – the installation becomes part of the interior.
No box in the wall, but you want the Sedna series? There are surface mounting adapters (boxes)that take the same flush-mounted devices. For the retro series – surface mounting box.
IP rating by location
In the IP code, the first digit shows protection against solid particles and dust, the second against water (EN 60529). Usually the higher the number, the better the protection (except IPX7/IPX8 – resistance to immersion does not necessarily mean resistance to jets), but the IP rating applies only when the cover is closed and the cable entry is properly sealed.
|
IP |
Meaning |
Suitable for |
|
IP20 |
Protection against finger contact with live parts; no protection against water |
Dry rooms: living rooms, corridors, offices |
|
IP41 |
Protection against objects >1 mm and vertically falling drops |
Floor socket covers in dry-cleaned floors (for wet-cleaned – IP44 or higher) |
|
IP44 |
Protection against objects >1 mm and water splashes from any direction |
Bathroom (outside the zones), kitchen near the sink, laundry |
|
IP54 |
Limited dust protection and splashes |
Garage, workshop, basement, outbuilding |
|
IP55 |
Limited dust protection and water jets |
Outdoors under a canopy, car wash, warehouse, production areas |
|
IP66 |
Dust-tight, resistant to powerful water jets |
Open outdoor areas, farms, areas washed down with water |
Bathroom zones. A bathroom is divided into zones: 0 – inside the bath or shower tray, 1 – above them up to 2.25 m (for a shower without tray – 1.2 m radius from the water outlet), 2 – a 0.6 m strip around zone 1. 230 V sockets are installed outside zones 0, 1 and 2, and the circuit is protected by a residual current device (RCD) IΔn ≤ 30 mA. No sockets are installed in the hot room of a sauna (HD 60364-7-703). Exact distances and permitted equipment are set by HD 60364-7-701 and the electrical design.
Switches and sockets: current, load, types
|
Component |
Purpose |
What to watch |
|
Switch (1 or 2 rockers) |
Switches a luminaire from one place; 2 rockers – two groups separately |
Usually 10 A. The 10AX marking means the switch is also tested with a fluorescent lamp type load (EN 60669-1) |
|
Two-way switch |
Control from two places: corridor, staircase, bedroom (at the door and the bed) |
Two two-way switches and two traveller wires between them are needed (usually a 3-core cable with PE) |
|
Intermediate switch |
Third and every additional control point |
Installed between two two-way switches – see the diagram |
|
Push button |
Doorbell, impulse relay, staircase timer |
The contact closes only while pressed – do not switch the load directly with it, only via a relay or timer |
|
Blind switch |
Blind or roller shutter drive up / down |
The rockers are interlocked so that both directions are never applied to the drive at the same time |
|
Socket 2P+E |
Household appliances 230 V |
16 A, earthed. In Lithuania, Latvia and Estonia type F (Schuko) sockets with side earth contacts are common; E/F plugs fit them too. In homes with children – with protective shutters |
|
Multiple socket |
2–4 sockets in one housing |
The total current of all outlets is the same 16 A, not 16 A per outlet |
|
Data, TV, audio, USB sockets |
RJ45 for computer network, TV aerial, audio, phone charging |
Fitted in the same frame as 230 V sockets, but low-voltage cables are routed separately from 230 V |
How to calculate: will the socket cope?
Current I = power P ÷ voltage U. For a 16 A, 230 V socket the maximum continuous power ≈ 16 × 230 = 3.68 kW – for all its outlets together.
Example: a 2.2 kW kettle and a 2.0 kW oil-filled radiator in the same triple socket → 4200 ÷ 230 = 18.3 A > 16 A. Such a small overload may not trip the circuit breaker for a long time (under EN 60898-1 it must not trip within an hour at 1.13 × In), while the socket contacts and terminals heat up. Connect such appliances to sockets on different circuits: if both sockets are on the same 16 A circuit, the total load is still too high.
In homes the socket circuit is usually protected by a 16 A circuit breaker and wired with 2.5 mm² copper cable, lighting – 10 A and 1.5 mm². The final selection depends on the design, cable installation method and length.
Socket blocks for furniture and desks
|
Type |
When to choose |
Where to look |
|
Recessed into the desktop (rectangular or round) |
Work desks, meeting tables; a closing lid protects against dust and crumbs |
Rectangular · round and wireless chargers |
|
Pop-up (tower) |
Kitchen island, reception – when sockets should not be visible |
Pop-up · modular |
|
On the desk edge or under the desk |
Rented premises, existing furniture – without cutting the desktop (with clamp or fixings) |
On the desk · towers |
|
Modular (22.5 mm and 45 mm modules) |
When you want to configure the set of connectors yourself: sockets, HDMI, RJ45, USB, blanks |
Modular blocks · modular connectors |
|
In a panel or cabinet |
Server, multimedia or technical cabinet |
For panels · modular |
|
With lighting |
Furniture where the socket must be found in the dark |
With LED lighting |
GST18 connector. Some furniture blocks are connected not with a plug but with a GST18 type (usually 3-pole, GST18i3) plug connector. This allows the furniture supply cable or another block to be connected without tools or unscrewing terminals. A block with a GST18 socket needs a matching supply cable with a GST18 plug – check the product page. Accessories include
surge protection and circuit breaker modules with the same connector.
Boxes: installation and junction
|
Box |
Purpose |
Tip |
|
Installation box for masonry |
For a switch or socket in masonry, concrete or block walls |
Set with filler or gypsum flush with the plaster; for several gangs – linkable boxes at 71 mm pitch so that multi-gang frames fit |
|
Installation box for drywall |
For lightweight partition walls |
Held by clamping claws; hole diameter as per product page (usually drilled with a Ø68 mm hole saw) |
|
Deep |
For dimmers, USB sockets, smart modules, when there are many wires in the box |
When building a new house deep boxes are worth choosing – smart control is easier to add later |
|
Junction |
For wire branches and connections |
Must remain accessible: do not plaster over, cover with tiles or furniture. Size – by the number of wires and terminals |
⚠ What to check before buying
Kibirkštis: „I bought white frames and cream switches – in one photo they looked the same. On the wall every guest sees the difference…“
|
What to check |
Why |
|
Series and colour |
Frames and devices are usually compatible only within the same series (or series declared compatible by the manufacturer); even within one series white, cream and anthracite differ clearly |
|
Mounting method |
A flush device needs a box in the wall; a surface one – a flat surface and cable entry from the top, bottom or side |
|
IP rating |
By location (see the table above); outdoors and in damp rooms – with a cover |
|
Current and load |
Switches usually 10 A, sockets 16 A. For powerful appliances (cooker, water heater) – a separate circuit and a dedicated connection |
|
Earthing and shutters |
A 2P+E socket is connected only with a PE conductor; in homes with children – protective shutters |
|
For a furniture block |
Cut-out dimensions and maximum desktop thickness, installation depth under the desktop, cable length and connection (Schuko plug or GST18) |
|
Box |
Wall type (masonry or drywall), depth, whether boxes can be linked for multi-gang frames |
✗ Most common mistakes
|
Mistake |
Consequence |
|
Several powerful appliances connected to one multiple socket |
Contacts and terminals overheat, the housing melts, the circuit breaker trips |
|
Indoor IP20 socket in a bathroom, garage or outdoors |
Moisture and condensation oxidise the contacts, the residual current device trips, risk of electric shock |
|
The switch breaks the neutral (N) instead of the phase (L) |
With the luminaire switched off, voltage remains in the lamp holder – you can get a shock when changing the bulb |
|
Wire joints plastered into the wall without a box |
A fault cannot be found without breaking the wall; a loose joint overheats |
|
Device from one series, frame from another |
The frame does not lock, gaps remain, the rocker sticks |
|
Furniture block supplied through several extension leads connected in series |
Overload and poor contact in the connections – risk of overheating and fire |
|
⚡ Working on a socket or switch without switching off the circuit breaker |
Danger of electric shock; one box may contain wires of several circuits |
⚡ Safe installation – Fazė's tip
Before replacing a switch or socket, switch off the circuit breaker and check for absence of voltage with a two-pole voltage tester – one box often contains wires of several circuits. A switch always breaks the phase conductor (L); the green-yellow PE conductor is connected to the earth terminal and never used as a neutral. Socket circuits used by ordinary persons must have residual current protection (RCD) IΔn ≤ 30 mA. In old houses, do not connect aluminium wires directly to device terminals unless the manufacturer allows it; for Al–Cu connections use dedicated terminals with contact paste, and preferably plan to replace the installation. New installation and connection of circuits in the distribution board is carried out by a qualified electrician.
☝ elsprendimai.eu recommends
Diagram: lighting from three places – wrong and right
Kibirkštis: „We installed three switches in a long corridor. From the ends the light somehow switches on, from the middle not always. And when changing the bulb I got a shock, although the light was off.“
Fazė: „The switches are fine – they are wired wrong. Let's see where the phase goes and what you fitted in the middle.“
✗ WRONG
① The neutral N is brought to the first switch, the phase L goes directly to the luminaire
↓
② Another two-way switch is fitted in the middle instead of an intermediate one
↓
③ Wires joined by twisting and plastered into the wall without a box
↓
④ Metal luminaire housing without a PE conductor
✓ RIGHT
① Phase L – to the common terminal of the first two-way switch; N and PE – directly to the luminaire
↓
② Two-way switches at the ends, an intermediate switch in the middle; two traveller wires between them; from the common terminal of the last two-way switch – a wire to the luminaire
↓
③ All connections – in terminals, in accessible junction boxes
↓
④ PE connected to the luminaire housing, the circuit protected by a circuit breaker
Why – explanation by diagram numbers
-
①: a switch breaks the conductor brought to it. If it is the neutral, the phase still reaches the luminaire when the light is off, and dangerous voltage remains in the lamp holder. That is why the phase is always brought to the switches, while the neutral and PE go directly to the luminaire.
-
②: a two-way switch has three terminals and only switches one wire to one of two. An intermediate switch has four terminals and „crosses“ both traveller wires. Only this circuit – two-way, intermediate, two-way – allows the light to be switched on and off from any place, regardless of the position of the other switches. Every additional control point is one more intermediate switch.
-
③: twisted and plastered wires loosen over time, their resistance grows and the joint heats up. Connections are made in terminals and left in accessible junction boxes so that they can be inspected.
-
④: if damaged insulation touches an unearthed metal housing, the housing becomes live, and the protection may not trip. The PE conductor provides a path for the fault current, so the circuit breaker or residual current device disconnects the circuit quickly.
⚠ The diagram is for guidance only. Check the wiring of switches, sockets and luminaires against the manufacturer's instructions and the design. Installation is carried out by, and is the responsibility of, a qualified electrician. UAB „Elektrotechnikos sprendimai“ is not liable for the connection or possible errors.
FAQ
Kibirkštis: Can a triple socket take three times more?
Fazė: No. A multiple socket is connected with one cable, so the total current of all its outlets is limited to 16 A – about 3.7 kW together.
Kibirkštis: What IP is needed in a bathroom?
Fazė: Outside the bathroom zones, sockets with a cover are installed, IP44 or higher is recommended, and the circuit must have 30 mA residual current protection. 230 V sockets are not installed close to the bath or shower – exact distances are set by HD 60364-7-701.
Kibirkštis: Can Sedna frames be used with switches from other manufacturers?
Fazė: No. Devices from other manufacturers do not lock into a Sedna frame. Combine Sedna only with devices declared compatible by Schneider Electric and components of the same colour.
Kibirkštis: When is a deep installation box needed?
Fazė: When you install a dimmer, USB socket, smart module or when many wires are connected in the box. A standard box is enough for an ordinary switch or socket, but in a new house deep boxes leave reserve for the future.
Kibirkštis: How do I connect a socket block in the desk?
Fazė: Most blocks have a cable with a Schuko plug and are plugged into the nearest wall socket; blocks with a GST18 connector – via a dedicated GST18 supply cable. Do not supply the block through several extension leads connected in series.
Kibirkštis: What does the 10AX marking on a switch mean?
Fazė: The rated current of the switch is 10 A, and the letter X shows that it is also tested with a fluorescent lamp type load. LED drivers also cause a short inrush current when switched on, so for lighting choose a 10AX switch and check the maximum LED load (W) stated by the manufacturer – it is often much lower than 10 A × 230 V.
Sources: technical data from elsprendimai.eu product pages (Schneider Electric Sedna Design, ABB Basic55, Legrand Plexo, Bachmann, TEM, GTV, Famatel, Makel and others); EN 60529 (IP ratings); EN 60669-1 (household switches); IEC 60884-1 (plugs and socket-outlets); IEC/TR 60083 (socket types); HD 60364-4-41 (protection against electric shock, additional 30 mA protection); HD 60364-5-52 (wiring systems, accessibility of connections); HD 60364-7-701 (bathrooms); HD 60364-7-703 (saunas); EN 60898-1 (circuit breakers). Checked 2026-10-17.
Send us a plan or a list – we will put together the installation
Specify the rooms, preferred series and colour, number of switches and sockets, or send the electrical plan. We will offer compatible devices, frames, boxes and furniture blocks – with price and delivery time.
Get a quote →