Products catalog

  • Climate controller for poultry and livestock houses | 6 analogue inputs, 10 relays, 2 × 0–10 V | age curves | 115/230 V AC | Elsp Group

    Code: ES-TEMPRON610

    Climate controller for poultry and livestock buildings: 6 analogue and 4 digital inputs, 10 relay outputs and 2 analogue 0–10 V outputs. It adjusts temperature according to a bird age curve, supply 115/230 V AC.

  • Climate controller for poultry and livestock houses, 115/230 V AC

    This climate controller automatically maintains temperature, humidity and ventilation in poultry houses and livestock buildings. It has 6 analogue inputs for temperature, humidity (0–10 V) and pressure (0–10 V), 4 digital inputs, 10 relay outputs and 2 analogue 0–10 V outputs. The controller changes the temperature setpoint according to bird age, so the climate adapts to the growing stage without manual resetting.

    ⚠ Relay outputs are dry contacts, max. 230 V / 2 A. Connect fans, heaters and other heavy loads only via contactors or interposing relays.
    Key idea:
    In poultry farming the temperature must drop every day according to age – easy to forget when done manually. The controller does it itself according to the entered curve, and 10 relays plus 2 analogue outputs let one device control fans, heaters, inlets and cooling. Measuring accuracy of ±0.2 °C helps keep the climate stable.
    Analogue inputs
    6
    Relay outputs
    10 × max. 230 V / 2 A
    Analogue outputs
    2 × 0–10 V
    Supply
    115/230 V AC

    Operating principle

    Temperature sensors and humidity (0–10 V) and pressure (0–10 V) sensors are connected to the analogue inputs. The controller compares readings with setpoints and switches fans, heaters or cooling via relays, while the 0–10 V outputs smoothly control, for example, fan speed or inlet position.

    The temperature reduction curve automatically changes the temperature setpoint according to bird age. The weight curve lets you follow growth by age.

    The 4 digital inputs are used for additional signals – for example door, alarm or equipment status contacts. Operation is possible from the controller's 6-digit 7-segment display, from PC software and, with a GSM module (accessory), remote notifications can be received.

    Why choose this climate controller?
    It combines measurement, climate logic and output control in one device designed for poultry farming. The automatic age curve reduces the risk of human error, and analogue outputs allow ventilation to be controlled smoothly rather than just on and off.

    Technical specifications

    Product type Climate controller for livestock and poultry buildings
    Manufacturer Elsp Group
    Supply 115/230 V AC
    Analogue inputs 6 (temperature, humidity 0–10 V, pressure 0–10 V)
    Digital inputs 4
    Relay outputs 10 dry contacts, max. 230 V / 2 A
    Analogue outputs 2 × 0–10 V
    Curves temperature reduction and weight by bird age
    Display 6-digit, 7-segment
    Measuring accuracy ±0.2 °C
    Remote control PC software; GSM module – accessory

    Main functions

    • Temperature control by age – setpoint changes automatically according to the curve
    • Weight curve – growth tracking by bird age
    • Humidity measurement – via a 0–10 V sensor input
    • Pressure measurement – via a 0–10 V input, e.g. for room pressure difference
    • 10 relay outputs – control of fans, heaters, cooling and other equipment
    • 2 analogue 0–10 V outputs – smooth control of fans or inlets
    • 4 digital inputs – additional status and alarm signals
    • PC control – settings and monitoring from a computer
    • GSM notifications – with an additional module

    How does it differ from similar products?

    Simple ventilation thermostat Controls one or a few relays at a fixed temperature. This controller has 10 relays, 2 analogue outputs, humidity and pressure inputs and an age curve.
    General-purpose PLC Climate logic has to be programmed. This controller has ready-made poultry functions.
    Stepped ventilation controller with NTC sensor Switches fans in stages by temperature, but has no age curves, 0–10 V outputs or pressure measurement.

    Where is it used?

    • Broiler houses
    • Laying hen and pullet houses
    • Pig houses
    • Calf barns and other livestock buildings
    • Hatching and rearing rooms
    • Farms that need remote climate monitoring

    Use by need

    Beginner.
    To start, connect temperature sensors, heating and fans via contactors and enter the age curve – the controller will then work on its own.
    Experienced installer.
    Use the 0–10 V outputs for fan speed controllers or inlet actuators, and the pressure input to monitor room pressure difference.
    Energy engineer / designer.
    When designing, consider the currents of all loads, provide contactors, alarm signalling via digital inputs and GSM notifications for on-duty staff.

    Practical use

    In a broiler house a high temperature is needed in the first days and progressively less as the birds grow. With the temperature reduction curve entered, the controller lowers the setpoint every day by itself, controls heaters and fans via relays and contactors, and fan speed via a 0–10 V signal. If the temperature goes out of range, the GSM module sends a message to the farmer.

    Pros / advantages

    • Automatic temperature curve by bird age
    • 10 relays and 2 analogue 0–10 V outputs
    • Temperature, humidity and pressure inputs
    • Accuracy ±0.2 °C
    • PC control and GSM notifications (with accessory)
    • Common 115/230 V AC supply

    Cons / limitations

    • Relay contacts max. 230 V / 2 A – heavy loads need contactors
    • Sensors and GSM module are not included
    • Many functions mean initial setup takes longer
    • IP rating and dimensions are not stated in the description – check before designing

    Safety and installation notes

    • ⚡ The controller is connected to a 115/230 V AC supply. Installation by a qualified electrician with the power switched off.
    • ⚡ Do not exceed 230 V / 2 A on the relay outputs – connect motors and heaters via contactors with appropriate protection.
    • Route 0–10 V sensor and output cables separately from power cables.
    • Install the controller in a panel or technical room protected from moisture, dust and the aggressive environment of livestock rooms.
    • Provide alarm signalling: a controller failure in a livestock building can endanger the animals.

    Quick selection guide

    6 AI / 4 DI
    10 relays
    2 × 0–10 V
    115/230 V AC
    Suitable when you need:
    • to lower the temperature automatically according to bird age
    • to control fans, heating and cooling from one device
    • to control fan speed smoothly with a 0–10 V signal
    • to monitor the climate from a PC and receive GSM notifications
    Check before choosing:
    • load currents and the need for contactors
    • which sensors will be connected – temperature, 0–10 V humidity and pressure
    • whether a GSM module is required
    • the installation location and its protection from the environment
    Important reminder: The controller does not replace safety protection: fan motors need contactors and circuit breakers, and critical buildings need independent alarm signalling.
    ☝ Elsprendimai.eu recommends:

    FAQ

    How many devices can be controlled?
    The controller has 10 relay outputs and 2 analogue 0–10 V outputs. Heavy loads are connected via contactors.
    What is the relay contact rating?
    Dry contacts, max. 230 V / 2 A.
    Which sensors can be connected?
    Temperature, humidity (0–10 V) and pressure (0–10 V) sensors are connected to the 6 analogue inputs.
    How does the age curve work?
    You enter the temperature for different bird age days and the controller changes the setpoint automatically.
    Can it be controlled remotely?
    Yes – from PC software, and notifications can be received with an additional GSM module.
    What is the supply voltage?
    115/230 V AC.

    Sources: Supplier technical data (existing product description). Checked 2026-10-18.

    Poultry house climate controller – age curves, 10 relays, 0–10 V

    A climate controller with 6 analogue and 4 digital inputs, 10 relays and 2 analogue 0–10 V outputs automatically maintains the climate in poultry houses and livestock buildings. Temperature curve by bird age, ±0.2 °C accuracy and 115/230 V AC supply.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    IP surveillance camera | Turret | 4 MP | 2.8 mm | IR 30 m | WDR 120 dB | PoE | IP66 | Hikvision DS-2CD2345FWD-I
    Code: DS-2CD2345FWD-I

    Hikvision DS-2CD2345FWD-I is a 4 MP (2688 × 1520) turret camera with a 1/2.5" sensor, 120 dB WDR and IR up to 30 m. Line-crossing, intrusion and unattended-object detection, H.265+, PoE 802.3af, microSD up to 128 GB, IP66.

    Price 137.00 € VAT incl.
    ( 113.22 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information