Duct humidity sensor | 0–100 % RH | 0–5 V / 0–10 V
Code: SKU#165268873591752961Duct relative humidity sensor for ventilation ducts. Measures up to 100 % RH and sends an analogue 0–5 V or 0–10 V signal to the controller.
-
Duct humidity sensor | 0–100 % RH | 0–5 V / 0–10 V
This duct sensor measures air relative humidity in a ventilation duct through a metal probe. According to the supplier, the measuring range reaches 100 % RH, output: 0–5 V / 0–10 V. The manufacturer is not confirmed, so please confirm the exact parameters before ordering.
Key point:
Humidity in the duct reflects the condition of the whole served zone, so the controller can regulate ventilation, humidification or dehumidification according to actual demand. The analogue signal connects directly to the controller input.Mounting
DuctMeasures
Relative humidityRange
up to 100 % RHOutput
0–5 V / 0–10 VCommunication interfaces and integration
0–5 V / 0–10 V Analogue humidity signal for ventilation and HVAC controllers. Operating principle
The probe is inserted into a straight duct section and the housing is fixed outside. Power and the analogue output to the controller are connected.
The sensor measures relative air humidity and converts it into a 0–5 V or 0–10 V signal.
Based on the signal, the controller changes fan speed or switches a humidifier or dehumidifier.
Why choose a duct humidity sensor?
The sensor gives a simple analogue signal accepted by most ventilation controllers. This allows humidity control where Modbus is not needed.Technical specifications
Product type Duct relative humidity sensor Manufacturer / model not confirmed Mounting in a duct, metal probe Measured value relative humidity Measuring range up to 100 % RH (per supplier data) Output 0–5 V / 0–10 V (per supplier data) Key functions
- Analogue output – 0–5 V / 0–10 V for standard controllers
- Metal duct probe – measurement in the airflow
- Range up to 100 % RH – also suits humid extract air
- Simple wiring – no programming or Modbus settings
- Duct mounting – housing outside, service without opening the duct
How does it differ from similar products?
Sentera DSTHF-3 (22713) Duct T/RH transmitter with a confirmed specification and Modbus RTU – for documented projects. Duct T/RH sensor with LCD (5273) Also measures temperature, has an LCD and 0–10 V / 4–20 mA output. Room RH sensor with Modbus RTU (3481) VTS transmitter with 0–5 / 0–10 V and RS485 Modbus RTU, temperature via Modbus. Where is it used?
- Extract air ducts of ventilation units
- Heat recovery units
- Pool and spa ventilation
- Humidification system control
- Warehouse and production ventilation
- Air handling units
Use by need
For beginners.
Check whether the controller accepts 0–5 V or 0–10 V and connect the matching output.For experienced installers.
Insert the probe into the middle of the duct in a straight section, away from humidifiers, heaters and bends.For engineers / designers.
If you need temperature, Modbus or documented parameters, choose Sentera DSTHF-3 or DCTHM-2.Practical application
Situation: a pool ventilation unit controller has a free 0–10 V input, and extract air humidity varies with the number of visitors. Solution: a duct humidity sensor is installed in the extract duct. Result: the controller increases airflow only when humidity rises and saves energy at quiet times.Pros / advantages
- Analogue 0–5 V / 0–10 V output
- Metal duct probe
- Range up to 100 % RH
- Simple connection to existing controllers
- Housing outside the duct – easy to service
Cons / limitations
- Manufacturer and full specification not confirmed
- Temperature measurement not stated – for T and RH choose the duct T/RH sensor with LCD (5273)
- No Modbus – for digital integration choose Sentera DCTHM-2 (22712)
Safety and installation notes
- ⚡ Make connections with the power switched off.
- ⚡ Check supply voltage and terminal marking against the device label before wiring.
- Route signal cables separately from power cables; use shielded cable for long lines.
- Do not install the probe directly after a humidifier – droplets and mist will distort readings.
Quick selection guide
DuctRHup to 100 % RH0–5 / 0–10 VSuitable when you need:- an analogue humidity signal for a controller
- measurement in a duct
- humidity control without Modbus
- simple wiring
Check before choosing:- supply voltage on the device label
- whether the controller accepts 0–5 V or 0–10 V
- probe length versus duct diameter
- whether temperature measurement is also needed
Important reminder: This is a measuring sensor, not a hygrostat: it has no relay output and does not control a humidifier or fan by itself. The controller makes decisions based on its signal.☝ Elsprendimai.eu recommends:- Sentera DSTHF-3 – Sentera DSTHF-3 – duct T/RH transmitter with a confirmed specification.
- Sentera DCTHM-2 – Sentera DCTHM-2 – duct sensor with Modbus RTU and PoM 24 V DC.
- 0–10 V DC / 4–20 mA – Duct T/RH sensor with LCD – when you need both temperature and a display.
- Temperature and humidity sensor selection guide – Temperature and humidity sensor guide – a quick comparison of all types in the group.
FAQ
Does the sensor measure temperature?
The name states relative humidity only. If you also need temperature, choose a duct T/RH sensor.Which output to choose – 0–5 V or 0–10 V?
The one your controller's analogue input accepts. Most ventilation controllers use 0–10 V.Can the sensor switch a humidifier by itself?
No. It sends an analogue signal and the controller makes the decision. Direct control requires a hygrostat with a relay.Where should the probe go in the duct?
In a straight duct section, with the probe tip in the middle of the airflow, away from humidifiers, heaters and bends.Is there a Modbus version?
Modbus is not stated for this sensor. The VTS room transmitter (3481) has analogue and Modbus output; for duct mounting choose Sentera DCTHM-2.Is it suitable for pool ventilation?
Yes, as a humidity signal for the controller. Install the probe in the extract duct, not in the pool hall itself.Sources: supplier product name and photo; manufacturer datasheet not found. Checked 2026-10-19.
Duct humidity sensor 0–5 V / 0–10 V
Duct relative humidity sensor with a metal probe and 0–5 V / 0–10 V output for ventilation controllers. Suitable for extract ducts, heat recovery units and pool ventilation.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Price 24.20 € VAT incl.( 20.00 € VAT excl. )Price 130.87 € VAT incl.( 108.16 € VAT excl. )204.16 €You save 73.29 €