Products catalog

  • Audible signal device | 30mm | 230V | IP40 | black

    Code: AD22-30MDF

    Panel-mounted audible alarm (buzzer) – a compact 230V AC audible warning device designed for control panels, automation cabinets and equipment panels. The buzzer is panel-mounted using an M30 / approx. Ø30mm mounting hole, consumes up to 20mA, operates at 50–60Hz and has an IP40 protection rating. Suitable for audible indication of faults, alarms, process completion or other system statuses. 

  • Panel buzzer | 230V AC | ≤20mA | 50–60Hz | Ø30mm | IP40

    Panel buzzer – an electrical signalling device designed to provide an audible indication of equipment status, faults, alarms, process completion or another event defined within a control system. The buzzer is powered by 230V AC and is intended for installation on the front of control panels, automation cabinets, machine control panels and other electrical systems.

    The compact panel-mount design is intended for installation in an approximately Ø30mm mounting position. The diameter of the buzzer head is approximately Ø36.2mm, allowing the device to remain clearly visible while occupying minimal space on the control panel.

    Audible warning for control and automation systems

    The buzzer is designed to generate an audible warning signal when 230V AC is applied to its supply circuit. It can be integrated into control circuits together with relays, contactors, controllers, sensors and other automation equipment.

    230V AC
    Operating voltage
    ≤20mA
    Current consumption
    50–60Hz
    Operating frequency
    IP40
    Protection degree
    Ø30mm
    Panel mounting

    Application

    The panel buzzer is designed to provide audible information to an operator or service personnel about the status of equipment or a technological process.

    It can be used as an audible indicator for alarms, faults, emergency conditions, process completion, activation or other events defined by the control system.

    For 230V AC control circuits

    Designed for 230V AC supply. Before connection, make sure that the control circuit voltage matches the rated voltage of the buzzer.

    Operating principle

    When 230V AC is applied to the buzzer supply terminals, the device generates an audible signal. In this way, an electrical control signal is converted into a clearly audible warning for the operator.

    The buzzer can be controlled via a controller output, relay, contactor, limit switch or another properly selected control element, depending on the electrical diagram of the particular system.

    Panel mounting

    The audible signalling device is designed for installation in a control panel or electrical cabinet door. The mounting section has an M30 thread, while the front head diameter is Ø36.2mm.

    The maximum specified panel thickness is 5mm. Above the panel, the buzzer head protrudes by approximately 14.6mm, while the main body section below the panel surface is approximately 40mm long.

    Main dimensions

    Parameter Value Description
    Front diameter Ø36.2mm Visible buzzer head diameter
    Mounting thread M30 For panel mounting
    Projection above panel 14.6mm According to drawing
    Body length below panel 40mm According to drawing
    Maximum panel thickness 5mm 5 Max according to drawing
    Lower body diameter Ø20.3mm According to drawing

    Technical specification

    Product type Panel audible signalling device / buzzer
    Rated voltage 230V AC
    Current consumption ≤20mA
    Operating frequency 50–60Hz AC
    Protection degree IP40
    Operating temperature range -25°C...+55°C
    Mounting type Panel mounting
    Mounting thread M30
    Front diameter Ø36.2mm
    Maximum panel thickness 5mm
    Body colour Black
    Conformity marking CE
    Specified standards IEC 947-5-1 / EN 60947-5-1

    IP40 protection

    The IP40 protection degree means that the enclosure provides protection against the ingress of solid objects of a certain size, but does not provide protection against water.

    For this reason, the buzzer is primarily suitable for use in control cabinets, panels and other locations where it is not directly exposed to water, rain or intensive moisture.

    Main features

    • 230V AC supply.
    • Low current consumption – ≤20mA.
    • 50–60Hz operating frequency.
    • Panel mounting.
    • M30 mounting thread.
    • Ø36.2mm front section.
    • IP40 protection degree.
    • Operating temperature from -25°C to +55°C.
    • Compact design for control cabinets and automation panels.

    Advantages

    • Direct 230V AC supply allows use in many standard control circuits.
    • Low current consumption – no more than 20mA.
    • Compact panel mounting saves space in the control cabinet.
    • Wide operating temperature range from -25°C to +55°C.
    • Audible signal allows the operator to be alerted without looking directly at the control panel.
    • Simple integration into relay-based and automation control circuits.

    Disadvantages / limitations

    • IP40 does not provide protection against water, therefore the product should not be directly exposed to rain or water splashes.
    • Designed for 230V AC. It must not be connected to a different voltage.
    • Not intended to be used as a standalone safety system. Its purpose is audible signalling within a control circuit.
    • The protection degree of the mounting location also depends on the panel, installation quality and overall construction.

    Suitable for

    • Electrical control panels
    • Automation cabinets
    • Machine and equipment control panels
    • Fault and alarm signalling
    • Audible indication of technological process status
    • Relay and PLC-controlled systems where the output circuit is suitable for a 230V AC load
    • Industrial and building automation systems

    Not suitable for

    • Direct outdoor installation without additional protection against water
    • 24V, 48V or other control circuits
    • Locations requiring IP65 or a higher protection degree
    • Environments outside the -25°C...+55°C operating temperature range
    • Use as the only emergency safety measure

    Practical application example

    In an automation cabinet, a controller monitors the operation of equipment. When a fault condition is detected, the controller output activates the appropriate relay.

    The relay contact switches on the power supply circuit of the 230V AC buzzer, immediately alerting the operator with an audible signal.

    Once the fault has been cleared or the alarm acknowledged, the control system disconnects the buzzer supply and the audible signal stops.

    The exact control logic depends on the specific electrical diagram and automation system used.

    Installation

    The buzzer is installed in a control panel or cabinet door using its M30 mounting section. Before installation, the panel opening dimensions must be checked and the panel thickness must not exceed the specified product limit.

    The electrical connection must be made according to the 230V AC control circuit diagram. Before carrying out installation or wiring work, the circuit must be disconnected from the power supply.

    Frequently asked questions (FAQ)

    What is a panel buzzer?

    It is an electrical device mounted in a control panel that generates an audible warning signal when supply voltage is applied.

    What is the voltage of this buzzer?

    230V AC.

    How much current does it consume?

    No more than 20mA.

    What is the operating frequency?

    50–60Hz AC.

    What is the protection degree?

    IP40.

    Is the buzzer protected against water?

    IP40 does not indicate protection against water, therefore the product is not intended for direct exposure to rain or water.

    What is the operating temperature?

    From -25°C to +55°C.

    What mounting size is required?

    The buzzer has an M30 panel mounting section. The front head diameter is Ø36.2mm.

    Where is it most commonly used?

    In control panels, automation cabinets, equipment panels and other systems where an audible status or alarm signal is required.

    Important electrical safety information

    The product is powered by 230V AC. Installation, connection and maintenance work must only be carried out with the power switched off and in accordance with applicable electrical safety requirements.

    Before installation, check the supply voltage, mounting opening, panel thickness, environmental conditions and compatibility with the specific control circuit.

    Panel buzzer – a 230V AC audible warning device for control and automation systems. Current consumption up to 20mA, operating frequency 50–60Hz, protection degree IP40, operating temperature from -25°C to +55°C. M30 panel mounting, front diameter Ø36.2mm.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information