    Compact 40 g aerosol fire suppression module designed for localized protection of electrical, automation, PLC, and other enclosed technical cabinets and boxes up to 0.4 m³. The module can be activated automatically by a thermal line (~170 ±10 °C) or by an electrical 5–24 V DC signal. It is mounted directly on a flat surface and measures 136 × 105 × 14 mm. Operating temperature: –50 °C to +90 °C. Service life: up to 10 years. 

  • Aerosol Fire Extinguishing Module | 30g | 0.3m³ | 5–24V DC | Thermal and Electrical Activation

    Aerosol Fire Extinguishing Module | 40g | up to 0.4m³ | 5-24V DC | Thermal and Electrical Activation

    Aerosol fire extinguishing module – a compact device designed for local fire protection in electrical, automation and other enclosed technical spaces. The module is mounted on a flat surface and can be activated in two ways: automatically via a thermal activation line or electrically using a 5–24V DC activation circuit. The thermal line activates when directly exposed to flame or when its temperature reaches approximately 170±10°C. For electrical activation, the module is used together with a fire detector and controller: when the detector detects a fire, the controller sends a 5–24V DC activation signal with a current greater than 350mA. The device contains 40g of aerosol-generating chemical agent, while the protected volume is up to 0.4m³ when the extinguishing density is 100g/m³.

    Two activation methods – automatic thermal and 5–24V DC electrical

    The thermal activation line allows the module to activate automatically without an external detector: when it is directly exposed to flame or its temperature reaches approximately 170±10°C, the extinguishing process is initiated. For electrical activation, the module is connected to a 5–24V DC activation circuit and used together with a fire detector and controller. The controller output must provide an activation current greater than 350mA.

    40g
    Amount of chemical agent
    0.4m³
    Protected volume
    5–24V DC
    Electrical activation voltage
    >350mA
    Activation current

    Operating principle and main functions

    Function Parameter Operating principle
    Automatic thermal activation 170±10°C When the thermal activation line is directly exposed to flame or its temperature reaches approximately 170±10°C, the module activates automatically and starts the extinguishing process.
    Electrical activation 5-24V DC, >350mA The module is used together with a fire detector and controller. When the detector detects a fire, the controller sends a 5-24V DC activation signal with a current greater than 350mA.
    Aerosol generation 40g When the device is activated, the chemical extinguishing agent generates aerosol, which is dispersed throughout the protected enclosed space.
    Extinguishing density 100g/m³ The amount of extinguishing agent is selected according to the volume of the protected enclosed space.
    Protected volume Up to 0.4m³ Designed for local fire protection of small and medium-sized electrical, automation and other enclosed technical spaces.
    Installation On a flat surface The module is mounted inside the protected cabinet or technical enclosure on a suitably selected flat surface.

    How does automatic thermal activation work?

    The thermal activation line operates independently

    The thermal line is designed for automatic activation of the extinguishing module. When it is directly exposed to flame or the temperature at the activation point reaches approximately 170±10°C, the module activates automatically. This activation method does not require a signal from an external fire detector or controller.

    1. The extinguishing module is installed on a flat surface inside the protected technical space.
    2. The thermal activation line is positioned within the protected area according to the manufacturer's installation requirements.
    3. Under normal conditions, the module remains passive.
    4. In the event of a fire, flame or high temperature affects the thermal activation line.
    5. When the line temperature reaches approximately 170±10°C or it is directly exposed to flame, the aerosol generator is activated automatically.
    6. The generated extinguishing aerosol is dispersed throughout the protected enclosed space and suppresses the combustion process.

    How does 5–24V DC electrical activation work?

    Operation together with a fire detector and controller

    For electrical activation, the extinguishing module is used together with a fire detection sensor and controller. When the detector identifies signs of fire, the information is transmitted to the controller, which sends an activation signal to the extinguishing module. The activation voltage may range from 5V to 24V DC, but the activation current must be greater than 350mA.

    1. The fire detector monitors the protected technical space.
    2. When signs of fire are detected, the detector sends a signal to the controller.
    3. The controller processes the signal and sends a 5–24V DC activation command to the extinguishing module.
    4. The controller output must provide a current greater than 350mA.
    5. The extinguishing module is activated and begins generating extinguishing aerosol.
    6. The aerosol is dispersed throughout the protected enclosed space and suppresses the combustion process.
    Important: voltage alone is not sufficient

    For electrical activation, simply applying 5–24V DC is not sufficient. The activation circuit must be capable of supplying more than 350mA. Before connecting the module, it is essential to verify that the controller output can provide the required voltage and current.

    Protected volume up to 0.4m³

    One 40g module is designed to protect a volume of up to 0.4m³ when the extinguishing density is 100g/m³. When selecting the device, the actual internal volume of the protected space, ventilation openings, leakage, component arrangement and other installation conditions must be evaluated.

    Panel mounting on a flat surface

    The compact 136x105x14mm housing is mounted directly on a suitable flat surface inside an electrical or automation cabinet. Since no DIN rail is required for installation, the DIN rail space can remain available for circuit breakers, relays, contactors, PLC modules, power supplies and other electrical equipment.

    Fire classes and applications

    Class Application
    A For fires involving solid combustible materials according to the declared application of the product.
    B For fires involving flammable liquids according to the product specification.
    C For gas fires according to the product application range.
    E Specified by the manufacturer as an application class for the protection of electrical equipment fires.

    Technical specification

    Product type Aerosol fire extinguishing module
    Installation method Panel-mounted, installed on a flat surface
    Amount of extinguishing chemical agent 40g
    Protected volume Up to 0.4m³
    Extinguishing density 100g/m³
    Activation methods Automatic thermal and electrical
    Thermal activation principle When the thermal line is exposed to flame or the temperature reaches approximately 170±10°C
    Thermal activation temperature 170±10°C
    Electrical activation voltage 5-24V DC
    Electrical activation current >350mA
    Electrical activation principle Used together with a fire detector and controller; when the detector detects a fire, the controller sends a 5–24V DC activation signal with a current greater than 350mA
    Operating temperature -50°C ~ +90°C
    Ambient relative humidity ≤95% RH
    Dimensions 136x105x14mm
    Product weight 290g
    Application classes A, B, C, E
    Oxidising agents Sr(NO3)2, KNO3
    Oxidising agent content 70%
    Service life 10 years
    Applicable standard EN 15276-1:2019
    Certificates / conformity markings CE, TÜV, RoHS, ISO 9001, CMA, CNAS

    Application in electrical and automation cabinets

    Suitable for autonomous and controlled fire protection

    The two activation methods allow the module to be used in different protection systems. The thermal line provides automatic activation in direct response to flame or high temperature, while 5–24V DC electrical activation allows the extinguishing process to be initiated with the help of a fire detector and controller.

    Advantages / benefits

    • Two activation methods – automatic thermal and electrical.
    • Automatic thermal activation allows the module to activate when the thermal line is exposed to flame or reaches approximately 170±10°C.
    • 5–24V DC electrical activation provides flexibility when integrating the module into fire detection and control systems.
    • Activation current >350mA clearly defines the requirement for the controller activation output.
    • Protected volume up to 0.4m³ is suitable for small and medium-sized electrical and automation cabinets.
    • 40g of extinguishing agent and an extinguishing density of 100g/m³.
    • Compact 135x105x14mm dimensions allow the module to be integrated into limited technical spaces.
    • Flat-surface mounting does not require a DIN rail.
    • Wide operating temperature range from -50°C to +90°C.
    • Ambient relative humidity up to 95% RH allows use under various technical environmental conditions.
    • 10-year service life designed for long-term stationary protection.

    Disadvantages / limitations

    • Protected volume limit: one module is designed for spaces up to 0.4m³, therefore larger volumes require a separate engineering assessment.
    • Additional equipment required for electrical activation: the module must be used together with a suitable fire detector and controller.
    • Sufficient output current is required: 5–24V DC voltage alone is not sufficient – the controller activation output must be capable of supplying more than 350mA.
    • Single-use operating principle: after actual activation, the aerosol generator must be replaced with a new one.
    • Importance of enclosure tightness: ventilation openings, leakage and intensive air exchange may affect the aerosol concentration in the protected space.
    • Not a whole-room fire suppression system: the product is intended for local fire protection of an enclosed technical space.

    What is it suitable for? (Applications)

    • Electrical distribution cabinets
    • Automation and PLC control cabinets
    • Variable frequency drive and motor control cabinets
    • Power supply and control electronics enclosures
    • Communication and telecommunications equipment cabinets
    • Systems with a fire detector and 5–24V DC control circuit
    • Systems requiring automatic thermal activation
    • Local fire protection of contactors, relays, circuit breakers and other electrical equipment
    • Other enclosed technical spaces up to 0.4m³

    What is it not suitable for?

    • Spaces with a volume exceeding 0.4m³ without an additional engineering solution
    • Open or heavily ventilated spaces
    • Use as a manual portable fire extinguisher
    • Electrical activation from a controller whose output cannot supply more than 350mA
    • Electrical activation using a voltage higher than 24V DC
    • Automatic fire suppression of an entire room where a separately engineered fire suppression system is required
    • Systems that require a different type of fire extinguishing technology according to the project design

    Practical example

    The internal protected volume of an automation cabinet is approximately 0.35m³. The cabinet contains circuit breakers, contactors, power supplies, relays and control electronics. The 40g aerosol fire extinguishing module is mounted on a suitable flat internal surface of the cabinet. The thermal activation line is positioned within the protected area, allowing the module to activate automatically if the line is directly exposed to flame or its temperature reaches approximately 170±10°C. In addition, the module is connected to a fire detector and controller. For electrical activation, the controller must send a 5–24V DC signal and provide an activation current greater than 350mA.

    Frequently asked questions (FAQ)

    What volume is this module designed to protect?

    One 40g module is designed to protect an enclosed technical space of up to 0.4m³ when the extinguishing density is 100g/m³.

    How many activation methods does this module have?

    The module can be activated automatically by the thermal activation line or electrically through a 5–24V DC activation circuit.

    How does the thermal activation line work?

    When the thermal line is directly exposed to flame or its temperature reaches approximately 170±10°C, the extinguishing module activates automatically.

    Is a detector required for thermal activation?

    No. The thermal activation line operates automatically and can activate the module directly in response to flame or high temperature.

    How does electrical activation work?

    The module is used together with a fire detector and controller. When the detector detects a fire, the controller sends an electrical activation signal to the extinguishing module.

    What is the electrical activation voltage?

    The electrical activation voltage may range from 5V to 24V DC.

    What electrical activation current is required?

    The activation current must be greater than 350mA.

    Is any 24V controller output sufficient?

    No. Both the voltage and output current capability must be checked. The controller must be capable of sending a 5–24V DC activation signal and supplying more than 350mA of current.

    Is a controller required for electrical activation?

    According to the operating principle provided by the supplier, the electrical version is used together with a fire detector and controller, which sends the activation signal to the extinguishing module.

    Is a DIN rail required?

    No. The module is mounted directly on a flat surface.

    How much extinguishing agent is inside the module?

    The module contains 40g of aerosol-generating chemical agent.

    What are the dimensions and weight of the module?

    The module dimensions are 136x105x14mm and the product weight is 290g.

    What is the operating temperature?

    The operating ambient temperature range is from -50°C to +90°C.

    Can the module be reused after activation?

    No. The aerosol fire extinguishing generator is a single-use device and must be replaced with a new one after activation.

    Important fire safety and installation note

    The aerosol fire extinguishing module must be selected and installed according to the manufacturer's technical documentation, the actual volume of the protected space, ventilation openings, leakage, equipment arrangement, fire risk and applicable fire safety requirements. For electrical activation, the controller activation circuit must be 5–24V DC and capable of supplying more than 350mA. The thermal activation line must be positioned according to the manufacturer's installation instructions. The device must not be dismantled, mechanically damaged, heated or activated other than for its intended purpose. After activation, the product must be replaced with a new one.

    40g aerosol fire extinguishing module – a compact 136x105x14mm flat-surface-mounted device designed for local fire protection of electrical, automation and other enclosed technical spaces up to 0.4m³. The module can activate automatically when the thermal activation line is exposed to flame or reaches approximately 170±10°C, and it can also be electrically activated using a 5–24V DC signal with a current greater than 350mA.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.