Automatic aerosol fire extinguishing device | 50g | 170°C activation | 0.5m³
Code: ES-QRR0.05G/S-CFLCPrice 83.70 € VAT incl.( 69.17 € VAT excl. )Buy more, pay less10+ pcs. – 77.08 € for pcs. -7%Want another price? Suggest yours!Aerosol fire suppression module designed for the localized protection of electrical, automation, PLC, and other technical cabinets. The module contains 50 g of fire-extinguishing agent, providing protection for volumes up to 0.5 m³. It is automatically activated by a thermal line when the temperature reaches approximately 170 ±10 °C. The flat 140 × 47 × 17 mm housing is mounted on the inner surface of the cabinet and does not occupy space on the DIN rail.
-
Aerosol Fire Extinguishing Module for Electrical Panels | 50g | 0.5m³ | 170°C Aerosol Fire Extinguishing Module for Electrical Panels | 50g | up to 0.5m³ | Thermal Activation
Aerosol fire extinguishing module for electrical panels – a compact local protection device designed for installation inside electrical, automation and other small technical cabinets. The module is mounted on a flat surface inside the panel and activated by a thermal line when the temperature reaches approximately 170±10°C. The device contains 50g of aerosol-generating chemical agent, while the protected volume is up to 0.5m³ when the extinguishing density is 100g/m³.
Localised electrical panel protection for volumes up to 0.5m³Thanks to the flat 140x47x17mm construction, the device can be installed on the inner wall, door or another suitable flat surface of an electrical panel or technical cabinet. In the event of a fire, when the thermal activation line reaches the specified temperature, the aerosol generation process is initiated and the extinguishing agent is dispersed throughout the protected enclosed space.
50gAmount of chemical agent0.5m³Protected volume170±10°CActivation temperature10 yearsService lifeOperating principle and main functions
Function Parameter Operating principle Thermal activation 170±10°C When the activation line reaches the specified temperature, the extinguishing process is initiated. Aerosol generation 50g When the device is activated, the chemical composition generates extinguishing aerosol, which is dispersed throughout the protected space. Extinguishing density 100g/m³ Indicates the design quantity of extinguishing agent per unit of protected volume. Protected volume Up to 0.5m³ Designed for localised protection of small and medium-sized enclosed electrical spaces. Installation On a flat surface Mounted inside an electrical panel or technical cabinet on a suitably selected flat surface. How does the extinguishing module work?
- The device is installed on a flat surface inside the protected electrical or automation cabinet.
- The thermal activation line is positioned according to the installation requirements of the specific site and product.
- Under normal conditions, the extinguishing device remains passive.
- In the event of a fire, the temperature in the protected area rises.
- When the thermal line reaches approximately 170±10°C, the device is activated.
- The generated extinguishing aerosol is dispersed throughout the protected volume and acts on the combustion process.
Important: protected volume up to 0.5m³For one 50g module, the specified protected volume is up to 0.5m³ when the extinguishing density is 100g/m³. When selecting the device, the actual internal volume of the protected cabinet, ventilation openings, leakage, equipment arrangement and other design conditions must be evaluated.
Flat panel installationThe construction is only 17mm thick, allowing the module to be installed on the inner wall of the panel or another flat surface without occupying DIN rail space. This is particularly practical in densely equipped electrical and automation panels.
Fire classes and applications
Specified class Application A For fires involving solid combustible materials according to the declared application of the product. B For fires involving flammable liquids or fires of a similar nature according to the product specification. C For gas fires according to the declared scope of application. E Specified in the product documentation for protection of electrical equipment. The specific application must be evaluated according to the product documentation and local requirements. Technical specification
Product type Aerosol fire extinguishing module for electrical panels Installation method Panel-mounted, installed on a flat surface Amount of extinguishing chemical agent 50g Protected volume Up to 0.5m³ Extinguishing density 100g/m³ Activation method Thermal line Activation temperature 170±10°C Operating temperature -50°C ~ +90°C Ambient relative humidity ≤95% RH Dimensions 140x47x17mm Product weight 135g Application classes A, B, C, E Oxidising agent Sr(NO3)2, KNO3 Oxidising agent content 70% Service life 10 years Applicable standard EN 15276-1:2019 Declared certificates / markings CE, TÜV, RoHS, ISO 9001, CMA, CNAS Application in electrical and automation cabinets
Does not occupy DIN rail spaceBecause the module is mounted on a flat surface, DIN rail space remains available for circuit breakers, contactors, relays, PLC modules, power supplies and other modular equipment. The 50g version is designed for a larger protected volume than the smaller 10g or 15g modules.
Advantages / benefits
- Specified protected volume up to 0.5m³ allows use in larger electrical and automation cabinets.
- 50g of extinguishing agent with a design extinguishing density of 100g/m³.
- Flat 17mm-thick housing allows the module to be installed in limited spaces.
- Mounted on a flat surface and does not occupy DIN rail space.
- Thermal activation initiates extinguishing when the specified activation temperature is reached.
- Wide operating temperature range from -50°C to +90°C.
- Ambient humidity up to 95% RH according to the specified operating conditions.
- Specified 10-year service life for long-term stationary protection.
Disadvantages / limitations
- Protected volume limit: up to 0.5m³ per module, therefore larger spaces require a separate engineering assessment.
- Thermal activation: the device activates only when the thermal line reaches the specified temperature.
- Single-use operation: after actual activation, the module must be replaced with a new one.
- Importance of enclosed space: large openings, ventilation or an insufficiently sealed enclosure may affect the aerosol concentration.
- Not a whole-room extinguishing system: this is a localised protection device intended for a small enclosed technical space.
What is it suitable for? (Applications)
- Electrical distribution panels
- Automation and PLC control cabinets
- Variable frequency drive and motor control cabinets
- Communication and telecommunications cabinets
- Electronics and control equipment enclosures
- Localised protection of power supply, contactor and relay areas
- Other enclosed technical spaces up to the specified protected volume
What is it not suitable for?
- Spaces with a volume exceeding 0.5m³ without additional engineering assessment
- Open or heavily ventilated spaces where the required aerosol concentration cannot be maintained
- Use as a manual portable fire extinguisher
- Systems where another type of automatic fire suppression system is required by the fire safety design
Practical example
The internal protected volume of an electrical control cabinet is approximately 0.4m³. Circuit breakers, contactors, power supplies, a variable frequency drive and other equipment are installed inside the cabinet. The 50g aerosol fire extinguishing module is mounted on a suitable flat internal surface, while the thermal activation line is positioned within the protected area. In the event of a fire, when the activation element reaches approximately 170±10°C, the module activates and disperses extinguishing aerosol throughout the protected space.
Frequently asked questions (FAQ)
What volume is this module designed to protect?One 50g module is specified for a protected volume of up to 0.5m³ when the design extinguishing density is 100g/m³.
How is the device installed?The module is designed for panel mounting on a suitable flat surface inside an electrical or automation cabinet.
Does it require a DIN rail?No. This version is mounted on a flat surface and is not a DIN rail module.
How is the extinguishing module activated?Activation is performed using a thermal line. The activation temperature is 170±10°C.
How much extinguishing agent is contained in the module?The quantity of chemical extinguishing agent is 50g.
What are the dimensions and weight of the device?The dimensions are 140x47x17mm and the specified product weight is 135g.
What is the operating temperature?The operating ambient temperature range is from -50°C to +90°C.
What is the specified service life?According to the provided product information, the service life is 10 years, provided that the manufacturer's installation, storage and operating requirements are followed.
Can the device be reused after activation?No. The aerosol fire extinguishing generator is a single-use device and must be replaced with a new one after activation.
Important fire safety and installation noteThe aerosol fire extinguishing module must be selected and installed according to the manufacturer's technical documentation, the actual volume of the protected space, ventilation openings, leakage, fire risk and applicable fire safety requirements. The specified 0.5m³ volume must not be automatically applied to any electrical cabinet without evaluating its construction. The device must not be dismantled, mechanically damaged, heated or activated other than for its intended purpose. After activation, the product must be replaced with a new one.
50g aerosol fire extinguishing module – a compact flat-surface-mounted device designed for localised protection of electrical and automation cabinets up to 0.5m³, using a 170±10°C thermal activation line and aerosol fire suppression technology.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Circuit breakers, also known as protective breakers or circuit interrupters, are essential components of electrical protection systems. They automatically disconnect the electrical circuit when it becomes overloaded or when a short circuit occurs. They are used in electrical installations to protect equipment and people from electrical faults. Circuit breakers come in various types and have different characteristics depending on the installation location, circuit load, and other specifications.
Circuit Breaker Characteristics:
B, C, and D Characteristics:
B characteristic: Used in residential areas or low-load systems. They operate when the current exceeds the nominal current by 3 to 5 times.
C characteristic: Commonly used in both residential and commercial or industrial spaces. Their operating threshold is 5 to 10 times the nominal current, making them suitable for loads with high inrush currents (e.g., motors, lighting systems).
D characteristic: Used in industrial installations where loads have very high inrush currents (e.g., compressors, transformers). They operate when the current exceeds the nominal by 10 to 20 times.
Advantages (Pros) of Circuit Breakers:Safety: Circuit breakers ensure that the circuit is automatically disconnected in case of overload or short circuit, preventing wire burning, equipment damage, or even fires.
Reliability: They are highly reliable and can operate for long periods without maintenance, reacting automatically when electrical faults occur.
Ease of use: There is no need to replace the breaker after it trips. After an overload or short circuit, the circuit breaker can simply be reset to its operational position, avoiding the need to replace fuses.
Precision: Circuit breakers operate accurately according to the nominal current and circuit characteristics, ensuring minimal unnecessary power interruption.
Protection against short circuits and overloads: Breakers not only protect against short circuits but also against prolonged overloads, which can be harmful to electrical systems.
Versatility: There are various types of circuit breakers suitable for different systems, from small household installations to large industrial systems.
Easy reset: After a trip, the breaker can simply be reset without the need to replace it (unlike fuses that need to be replaced after a trip).
Disadvantages (Cons) of Circuit Breakers:High cost: Circuit breakers, especially those with more complex functions (e.g., adjustable protection limits), are more expensive than simple fuses.
Limited operating range: While breakers provide protection against overloads and short circuits, they cannot protect against all types of electrical faults, such as overvoltage. Additional protection devices are required for that.
Larger size: Circuit breakers are generally larger than fuses, meaning their installation may require more space in the distribution panel.
Limited protection against frequent overloads: If the electrical system experiences frequent overloads, circuit breakers may not fully protect equipment from long-term damage caused by continuous overload exposure.
More complex repair: Some complex circuit breakers may require more maintenance or repairs if they malfunction or trip incorrectly.
Applications of Circuit Breakers:Household Installations:
B characteristic breakers are most commonly used in residential installations to protect circuits from short circuits and overloads. They are suitable for lighting circuits, plugs, and other low-load devices.
C characteristic breakers are also used in homes but are better suited for areas with higher inrush currents, such as electric motors or heaters.
Commercial and Industrial Installations:C characteristic breakers are often used in commercial and industrial buildings. They are suitable for electrical equipment with medium inrush currents.
D characteristic breakers are used in industrial equipment where large inrush currents occur, such as for heavy motors, transformers, or high-power equipment protection.
Large Mechanisms and Industrial Equipment:D characteristic breakers are used where the inrush currents are very high. This includes electrical network distribution sections, industrial machinery, and transformers.
Protection of Electronics Equipment:Certain types of circuit breakers are used to protect electronic equipment, such as in server rooms or other sensitive systems where fast and precise protection is required.
Conclusion:
Circuit breakers are essential in modern electrical systems to ensure safe power supply and protection from faults. They have many advantages, such as reliability, safety, and easy resetting, but they also have some drawbacks, such as higher cost and larger size. Their selection depends on the intended use and required protection parameters.K – Trips when the current is 8-12 times higher than the nominal current, designed to protect circuits powering motors, capacitors, and transformers.
S – Trips when the current is 13-17 times higher than the nominal current, designed for the protection of control transformers.
Z – Trips when the current is 2-3 times higher than the nominal current, designed for the protection of computer equipment and other electronic components and devices.
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Signal | indicator lamp | red | 10mm | 12VCode: ES-XD10-3RPrice 1.21 € VAT incl.( 1.00 € VAT excl. )Round membrane grommet | for Ø50 mm hole | 36 cables Ø3.5–5.5 mm | grey | IP65 | HT Hi Tech Polymers | HT-50 (HTL-50-36)Code: Sandariklis HT-50Price 1.75 € VAT incl.( 1.45 € VAT excl. )