Automatic aerosol fire suppression device for DIN rail | 10g | 170°C activation | 6 s suppression | ABCD class | for electrical cabinets | no power supply required
Code: ES-QRR0.01Automatic aerosol fire suppression device designed for rapid fire extinguishing at the very early stage of ignition. The device activates at approximately 170°C and releases fire-extinguishing aerosol within 6 seconds, effectively suppressing flames at an early stage. Mounted on a DIN rail, it requires no power supply – ensuring reliable 24/7 protection even in the event of a power outage.
-
Technical Specifications
Type: Automatic aerosol fire extinguishing device
Activation: thermal (without external power supply)
Activation temperature: ~170°C
Response time: up to 15 s
Extinguishing discharge time: ≤6 s
Extinguishing agent: Aerosol (dry extinguishing aerosol)
Fire classes: A / B / C / D
Extinguishing density: 100 g/m³
Agent quantity: 10 g
Protected volume: up to 0.1 m³
Active substance purity: >99.6%
Operating pressure: 1.6 MPa
Operating temperature: -50°C to +90°C
Humidity tolerance: <95% RH (without condensation)
Mounting: 35 mm DIN rail or 3M adhesive tape
Housing: steel + plastic
Color: red
Temperature sensors: 2 (top and bottom)
Cable length: 10 cm
Height: 90 mm
Width: 19 mm
Depth: 60 mm
Application: Electrical cabinets, automation panels, server / IT cabinets, solar inverter cabinets, battery cabinets, EV charging stationsFunctions
Automatic fire extinguishing without human intervention - the device independently detects critical temperature and activates without any control or signals
Aerosol fire extinguishing solution for electrical cabinets - effectively suppresses fire without damaging electrical equipment like water or foam
Fire extinguishing device operating without power supply - works even in case of power outage – maximum reliability in critical situations
Fast response – extinguishing within 6 seconds - ensures extremely fast reaction while the fire has not yet spread
DIN rail mounting - easily integrated into electrical panels, automation cabinets and distribution boxes
Wide range of fire classes (ABCD) - suitable for various fires – from solid materials to electrical equipment
Compact mini fire extinguishing system - suitable for small enclosed spaces – electrical cabinets, server rooms, control boxesUse
For household user: Used for home electrical panels, garages, workshops, protection of solar inverter systems, protects against fire and possible major losses
For companies and industry: Automation cabinets, server rooms, production equipment, electrical distribution panels, protection against production downtime and equipment damage
For company manager: Reduces the risk of financial losses, ensures uninterrupted operation, small investment – large protection, business safety 24/7 without additional maintenance
For electrician / engineer: Simple mounting on DIN rail, no need for additional wiring or power supply, reliable solution for projects, fast and efficient integration into systemsPractical application
Mounted in an electrical cabinet on a DIN rail, next to circuit breakers, contactors or inverters. When the temperature rises to ~170°C, the device automatically activates and extinguishes the fire source within a few seconds, protecting the equipment from greater damage.
Suitable for home panels, solar power systems, server rooms and industrial control cabinets as a simple, autonomous fire protection solution.Advantages
Automatic operation without human intervention
No power supply required
Fast response (6 s)
Easy mounting (DIN rail)
Suitable for electrical equipment
Protects against major losses
Operates 24/7Disadvantages
Designed for small enclosed spaces (up to 0.1 m³)
Single-useFAQ
Does the device require power supply?
No, it operates completely autonomously – no power supply is required.When does the device activate?
The device activates automatically when the temperature reaches approximately 170°C.Is it safe to use in electrical cabinets?
Yes, aerosol extinguishing is safe for electrical equipment and does not damage components like water.Can the device be reused?
No, after activation the device is single-use and must be replaced with a new one.Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.Circuit breakers, also known as protective breakers or circuit interrupters, are essential components of electrical protection systems. They automatically disconnect the electrical circuit when it becomes overloaded or when a short circuit occurs. They are used in electrical installations to protect equipment and people from electrical faults. Circuit breakers come in various types and have different characteristics depending on the installation location, circuit load, and other specifications.
Circuit Breaker Characteristics:
B, C, and D Characteristics:
B characteristic: Used in residential areas or low-load systems. They operate when the current exceeds the nominal current by 3 to 5 times.
C characteristic: Commonly used in both residential and commercial or industrial spaces. Their operating threshold is 5 to 10 times the nominal current, making them suitable for loads with high inrush currents (e.g., motors, lighting systems).
D characteristic: Used in industrial installations where loads have very high inrush currents (e.g., compressors, transformers). They operate when the current exceeds the nominal by 10 to 20 times.
Advantages (Pros) of Circuit Breakers:Safety: Circuit breakers ensure that the circuit is automatically disconnected in case of overload or short circuit, preventing wire burning, equipment damage, or even fires.
Reliability: They are highly reliable and can operate for long periods without maintenance, reacting automatically when electrical faults occur.
Ease of use: There is no need to replace the breaker after it trips. After an overload or short circuit, the circuit breaker can simply be reset to its operational position, avoiding the need to replace fuses.
Precision: Circuit breakers operate accurately according to the nominal current and circuit characteristics, ensuring minimal unnecessary power interruption.
Protection against short circuits and overloads: Breakers not only protect against short circuits but also against prolonged overloads, which can be harmful to electrical systems.
Versatility: There are various types of circuit breakers suitable for different systems, from small household installations to large industrial systems.
Easy reset: After a trip, the breaker can simply be reset without the need to replace it (unlike fuses that need to be replaced after a trip).
Disadvantages (Cons) of Circuit Breakers:High cost: Circuit breakers, especially those with more complex functions (e.g., adjustable protection limits), are more expensive than simple fuses.
Limited operating range: While breakers provide protection against overloads and short circuits, they cannot protect against all types of electrical faults, such as overvoltage. Additional protection devices are required for that.
Larger size: Circuit breakers are generally larger than fuses, meaning their installation may require more space in the distribution panel.
Limited protection against frequent overloads: If the electrical system experiences frequent overloads, circuit breakers may not fully protect equipment from long-term damage caused by continuous overload exposure.
More complex repair: Some complex circuit breakers may require more maintenance or repairs if they malfunction or trip incorrectly.
Applications of Circuit Breakers:Household Installations:
B characteristic breakers are most commonly used in residential installations to protect circuits from short circuits and overloads. They are suitable for lighting circuits, plugs, and other low-load devices.
C characteristic breakers are also used in homes but are better suited for areas with higher inrush currents, such as electric motors or heaters.
Commercial and Industrial Installations:C characteristic breakers are often used in commercial and industrial buildings. They are suitable for electrical equipment with medium inrush currents.
D characteristic breakers are used in industrial equipment where large inrush currents occur, such as for heavy motors, transformers, or high-power equipment protection.
Large Mechanisms and Industrial Equipment:D characteristic breakers are used where the inrush currents are very high. This includes electrical network distribution sections, industrial machinery, and transformers.
Protection of Electronics Equipment:Certain types of circuit breakers are used to protect electronic equipment, such as in server rooms or other sensitive systems where fast and precise protection is required.
Conclusion:
Circuit breakers are essential in modern electrical systems to ensure safe power supply and protection from faults. They have many advantages, such as reliability, safety, and easy resetting, but they also have some drawbacks, such as higher cost and larger size. Their selection depends on the intended use and required protection parameters.K – Trips when the current is 8-12 times higher than the nominal current, designed to protect circuits powering motors, capacitors, and transformers.
S – Trips when the current is 13-17 times higher than the nominal current, designed for the protection of control transformers.
Z – Trips when the current is 2-3 times higher than the nominal current, designed for the protection of computer equipment and other electronic components and devices.
This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Signal | indicator lamp | red | 10mm | 12VCode: ES-XD10-3RPrice 1.21 € VAT incl.( 1.00 € VAT excl. )Round membrane grommet | for Ø50 mm hole | 36 cables Ø3.5–5.5 mm | grey | IP65 | HT Hi Tech Polymers | HT-50 (HTL-50-36)Code: Sandariklis HT-50Price 1.75 € VAT incl.( 1.45 € VAT excl. )